# Zener Language

> Read or edit Zener HDL, package APIs, and tool-managed dependencies.

- Skill: `diodeinc/zener-language` (Agent Skill)
- Install (CLI): `npx skillmds@latest add diodeinc/zener-language`
- Raw SKILL.md: https://api.skillmd.com/api/skills/diodeinc/zener-language/raw
- Safety review: pending
- Works with: Claude Code, Claude.ai, OpenAI Codex
- Category: Coding & Dev Tools
- Author: diodeinc (https://skillmd.com/u/diodeinc)
- Updated: 2026-09-09
- Page: https://skillmd.com/skills/diodeinc/zener-language

---


# Zener Language

Zener is Starlark plus PCB-specific modules, typed electrical connections, physical parts, sourcing, layout, and diagnostics.

## Discover Before Authoring

Use `pcb doc --package @stdlib` or `pcb doc --package <package>` to inspect public APIs and their source roots. Read the installed implementation when exact behavior matters.

For CLI behavior, use the installed command's `--help`; do not invent or infer subcommands or flags. When version history matters, inspect the installed version and nearby entries in the [`pcb` changelog](https://github.com/diodeinc/pcb/blob/main/CHANGELOG.md) instead of relying on old examples.

## Modules and Components

A `.zen` file can be:

- a normal Starlark module imported with `load()`; or
- an instantiable schematic module imported with `Module()`.

Relative paths stay within the current package. Cross-package imports use full package URLs:

```zen
load("./helpers.zen", "helper")
LocalBlock = Module("./LocalBlock.zen")
RemoteBlock = Module("github.com/org/repo/modules/RemoteBlock.zen")
```

An instantiation passes `name=...`, its public `io()` and `config()` inputs, and optional properties such as `dnp`, `properties`, or `schematic`.

`name` establishes instance-path identity, not a fixed reference designator. Refdes-like names are only annotation hints; exact source-reference preservation is not supported.

Use refdes-like names only when the user explicitly asks. In that case, set `prefix=` on the underlying `Component()` to match the refdes prefix.

`Component()` creates a physical part from `name`, `symbol`, and `pins`. The selected symbol is the authority for its footprint, part identity, datasheet, and pins. Keep those properties correct in `.kicad_sym` rather than repeating them in Zener. Omit true `no_connect` pins; they are wired to `NotConnected()` automatically.

Use `Symbol(library, name=...)` for multi-symbol libraries. Use `Part(mpn=..., manufacturer=...)` only when the symbol does not already provide part identity.

`Layout(name, path)` associates reusable layout metadata with a module. Each entrypoint may declare at most one layout, with a config-independent path; use separate entrypoints for distinct layouts. A root-level `Project(name, path)` links persistent KiCad project files; its path is relative to the root `.zen` file.

## IO and Config

Define public electrical connections as flat top-level assignments:

```zen
VDD = io(Power(voltage="3.0V to 5.5V"))
GND = io(Ground)
EN = io(Net, optional=True)
```

Do not introduce legacy `Pins = struct(...)` wrappers in new or touched APIs.

With `optional=True`, an omitted IO receives an automatically generated net or interface.

`Net` is the base connection type. `Power`, `Ground`, `NotConnected`, and stdlib interfaces add constraints and semantics. Across an `io()` boundary, `NotConnected` can promote to any net type, a specialized net can demote to `Net`, and a plain `Net` does not automatically gain specialized semantics. Adapt intentionally with casts such as `Power(net, voltage=...)` or `Net(power_net)`.

Use stdlib interfaces such as `DiffPair`, `I2c`, `I3c`, `Spi`, `Qspi`, `Uart`, `Usart`, `Swd`, `Jtag`, `Usb2`, and `Usb3` when the grouped protocol semantics are meaningful.

Use `UartPair()` and `UsartPair()` when a point-to-point link should cross-connect the two endpoints.

Declare a voltage range on every public `Power` IO unless the API is intentionally generic.

Define non-electrical choices with typed `config()`:

```zen
output_voltage = config(Voltage, default="3.3V", allowed=["3.3V", "5V"])
```

Load physical value types from `@stdlib/units.zen`: `Voltage`, `Current`, `Resistance`, `Capacitance`, `Inductance`, `Impedance`, `Frequency`, `Temperature`, `Time`, and `Power`. String defaults and allowed values auto-convert to the declared physical type. Use enums for non-physical modes and strategies. Expose application-level choices rather than internal passive values or implementation details.

Physical constructors accept point values, engineering notation, ranges, and tolerances. Arithmetic tracks units. Equality between two physical values is strict; use `.matches(...)` for coercive comparison with a string or scalar. Inspect the installed API for other operations.

Enum defaults use the selected string value:

```zen
Mode = enum("PULLUP", "PULLDOWN")
mode = config(Mode, default="PULLUP")
```

## Stable Topology

Configs may change values and `dnp=` state, but should not add, remove, or reconnect schematic instances. Stable instance and net identity preserves layout and reviewability.

- Compute a selected value on one component when the nets do not change.
- Instantiate every mutually exclusive strap or option and DNP the inactive alternatives.
- Do not use conditional instantiation to change topology.
- Use an IC's internal pull-up or pull-down for its default mode when appropriate; add external bias components with `dnp=` only for populated alternatives.

Put non-trivial electrical calculations in named functions. Cite the relevant datasheet equation or table and snap calculated values with the appropriate stdlib E-series helper.

The available E-series helpers in `@stdlib/utils.zen` are `e3`, `e6`, `e12`, `e24`, `e48`, `e96`, and `e192`.

Use `check`, `warn`, `error`, and stdlib checks for enforceable electrical constraints rather than documenting them only in comments.

For reusable power-rail boundary checks, inspect and prefer `voltage_within(...)` from `@stdlib/checks.zen` instead of duplicating the constraint.

## Public Compatibility

Reusable-package compatibility includes the public `io()` and `config()` API, entrypoints, behavior, layout, and physical integration assumptions. A build of the current package does not prove existing consumers remain compatible.

If consumers must change to adopt an update, treat it as breaking. Document the migration and use a breaking commit.

## Schematic Position State

First inspect the root entrypoint for `Project(...)`:

- With `Project(...)`, the KiCad files under its `path` are persistent schematic state. Use `pcb apply schematic` to reconcile Zener changes and use `schematic-composition` with `agent-schema` for visual composition.
- Without `Project(...)`, the project uses the legacy generated schematic. `# pcb:sch <ID> ...` comments persist placement; preserve them during textual edits, add new code above the block, and do not use `agent-schema`.

To upgrade a legacy project, export before adding `Project(...)`:

```bash
pcb-sch export-kicad board.zen --output schematic
```

Then add `Project(name = "Board", path = "schematic")` to the root and run `pcb apply schematic --no-open board.zen` twice. The first pass may normalize the exported KiCad files; the second must report `schematic unchanged`.

When renaming or deleting an item, update or remove only its corresponding records. Do not add records or edit coordinates by hand unless the user requested schematic layout work.

## Packages and Dependencies

The stdlib is toolchain-managed and does not belong in `[dependencies]`. Other packages are declared by their `load()` or `Module()` imports, and the dependency state in `pcb.toml`, including indirect entries, is tool-managed.

Use `pcb list -m -u` to inspect compatible and breaking updates. Use `pcb add -u` for compatible updates and `pcb list -m -versions <url>` plus `pcb add <url>@<version>` for a specific or breaking version. Do not hand-edit resolved versions or use the legacy `pcb update` workflow.

Board roots contain workspace and board metadata. Registry roots contain reusable component and module members without a root board. Reusable packages contain their own direct dependencies and optional default parts.

## Style

Match the surrounding Zener code. Keep declarations concise, use comments for evidence or non-obvious judgment, and avoid decorative section banners or prose that restates the code. These cleanup rules never apply to `# pcb:sch` records.

Use established naming:

- public `io()` names: uppercase;
- `config()` names: lowercase;
- component instances: uppercase functional names; and
- differential signals: `_P` and `_N`.

Prefer stdlib generics for common passives, discretes, connectors, test points, and mechanical features. Inspect the current stdlib package rather than relying on a memorized inventory. Use `Rectifier`, `Zener`, or `Tvs` instead of the deprecated generic `Diode`.

For ordinary boards, prefer `Board(..., layers=<count>)`; standard defaults exist for 2, 4, 6, 8, and 10 layers. Customize them with `outer_copper_weight`, `copper_finish`, `solder_mask_color`, `track_widths`, and `via_dimensions`. Use explicit stackup and design-rule records only when those defaults are insufficient; an explicit `config` merges over the layers-derived defaults.

## Completion Evidence

Use each supported primitive for its own purpose:

- after changing imports or dependencies, run `pcb sync` from the relevant workspace or package;
- run `pcb fmt` on changed Zener;
- run `pcb build <path>` for affected entrypoints to evaluate the design and collect diagnostics; for registry package curation, use `pcb build -Wstyle <path>` to promote style advice to warnings; and
- use `pcb bom <entrypoint>.zen -f json` only when sourceability or part selection is relevant.

Use the applicable checks and engineering evidence for the changed API, circuit, or dependencies. Preserve schematic position state and report unverified work.