# Idrac

> Monitors and manages Dell PowerEdge servers via the iDRAC Redfish API, covering hardware status, health, sensors, power operations, inventory, and event logs.

- Skill: `johnalbertini14-glitch/idrac` (Agent Skill, multi-file: 4 files)
- Install (CLI): `npx skillmds add johnalbertini14-glitch/idrac`
- Raw SKILL.md: https://api.skillmd.com/api/skills/johnalbertini14-glitch/idrac/raw
- Safety review: CAUTION (external: skill-scanner PASS, skillspector CAUTION)
- Works with: Claude Code, Claude.ai, OpenAI Codex
- Category: DevOps & Infra, Monitoring & Observability
- Tags: Dell, Hardware Inventory, Idrac, Power Management, Poweredge, Redfish, Server Monitoring
- Author: johnalbertini14-glitch (https://skillmd.com/u/johnalbertini14-glitch)
- Updated: 2026-08-22
- Page: https://skillmd.com/skills/johnalbertini14-glitch/idrac

---


# iDRAC Skill

Monitor and manage Dell PowerEdge servers via iDRAC Redfish API.

## First-Time Setup

Create a config file at `~/.config/idrac-skill/config`:

```bash
mkdir -p ~/.config/idrac-skill
cat > ~/.config/idrac-skill/config <<'EOF'
# iDRAC connection settings
IDRAC_IP="<your-idrac-ip>"

# Credential source: "1password" | "file" | "env"
CREDS_SOURCE="file"

# For CREDS_SOURCE="1password":
#   OP_ITEM="<1password-item-name>"
#
# For CREDS_SOURCE="file":
#   Create ~/.idrac-credentials with contents: username:password
#   chmod 600 ~/.idrac-credentials
#
# For CREDS_SOURCE="env":
#   Export IDRAC_USER and IDRAC_PASS
EOF
```

## Authentication

The helper script supports three credential sources:

| Source | Config | How It Works |
|--------|--------|--------------|
| **1password** | `OP_ITEM="item-name"` | Pulls username:password via `op` CLI, caches to `~/.idrac-credentials` |
| **file** | (default) | Reads `~/.idrac-credentials` (format: `user:pass`, mode 600) |
| **env** | — | Uses `$IDRAC_USER` and `$IDRAC_PASS` environment variables |

## Helper Script

Location: `scripts/idrac.sh` (relative to this skill directory)

```bash
idrac.sh test            # Test connectivity and authentication
idrac.sh status          # System summary (model, power, CPU, memory)
idrac.sh health          # Health checks (temps, fans, power)
idrac.sh power           # Current power state
idrac.sh inventory       # Full hardware inventory
idrac.sh logs            # Recent system event log entries (last 10)
idrac.sh thermal         # Detailed temperature and fan status
idrac.sh storage         # RAID/disk status
idrac.sh reset-types     # Available power reset types
```

## Workflow

1. **Load config** from `~/.config/idrac-skill/config`
2. **Hydrate credentials** (JIT pattern) if needed
3. **Determine operation type:**
   - **Read-only** (status, health, logs, inventory) → Execute directly
   - **Destructive** (power off, restart, BIOS changes) → Confirm with user first
4. **Query Redfish API** via curl + Basic Auth (or session token for batch ops)
5. **Parse JSON** with jq
6. **Surface findings** to user in natural language
7. **Never expose credentials** in responses

## Endpoint Reference

For raw Redfish API endpoints (system info, thermal, storage, network, logs, power ops, BIOS, firmware, session auth, Dell OEM attributes):

→ See [references/endpoints.md](references/endpoints.md)

## Security Notes

- **Never log or display credentials** — use `--silent` and pipe to jq
- **Credential file** must be mode 600 (`chmod 600 ~/.idrac-credentials`)
- **TLS verification disabled** (`-k`) — iDRAC uses self-signed certs (acceptable for private networks)
- **Power operations are destructive** — confirm with user before executing shutdown/restart

## Compatibility

Works with Dell iDRAC 8 (Redfish 1.0–1.4) and iDRAC 9 (Redfish 1.6+). Covers PowerEdge 13th gen (R630/R730) through current gen. See endpoints reference for version-specific notes.

**Note:** iDRAC 8 API responses can take 5–10s per call. The `test` command makes 4 sequential calls (~30–40s total). Set exec timeouts accordingly. iDRAC 9 is significantly faster.

