# Matlab Evaluate Acoustic Metrics

> Select and use Audio Toolbox acoustic, psychoacoustic, and speech quality metrics. Use when computing loudness, sharpness, roughness, fluctuation strength, noise criteria (NC/RNC/RC), speech transmission index (STI), speech intelligibility index (SII), speech quality (ViSQOL, STOI), SPL, reverberation time (RT60), tone-to-noise ratio, or prominence ratio. Also use when asked about PESQ, POLQA, calibration factor, EBU R 128, LUFS, HVAC noise, background noise evaluation, or how to measure audio quality or noise compliance. Covers calibration, standard selection, signal alignment, and the complete function inventory including what does NOT exist.

- Skill: `matlab/matlab-evaluate-acoustic-metrics` (Agent Skill, multi-file: 9 files)
- Install (CLI): `npx get-skill add matlab/matlab-evaluate-acoustic-metrics`
- Raw SKILL.md: https://api.skillmd.com/api/skills/matlab/matlab-evaluate-acoustic-metrics/raw
- Safety review: pending (external: skill-scanner PASS, skillspector PASS)
- Works with: Claude Code, Claude.ai, OpenAI Codex
- Category: Coding & Dev Tools
- License: https://www.mathworks.com/content/dam/mathworks/license/pmrl/lic
- Author: matlab (https://skillmd.com/u/matlab)
- Updated: 2026-11-11
- Page: https://skillmd.com/skills/matlab/matlab-evaluate-acoustic-metrics

---


# Evaluate Acoustic Metrics

Select the correct Audio Toolbox function for acoustic measurement, apply proper calibration, and choose appropriate standards — instead of reimplementing algorithms or calling nonexistent functions.

## When to Use

- Computing psychoacoustic metrics (loudness, sharpness, roughness, fluctuation)
- Evaluating speech quality or intelligibility (ViSQOL, STOI, STI, SII)
- Assessing noise compliance (NC rating, RC rating, RNC, SIL)
- Measuring SPL from recordings (offline, calibrated)
- Computing broadcast loudness (EBU R 128 / LUFS)
- Measuring reverberation time (RT60) from impulse responses
- Detecting tonal content (tone-to-noise ratio, prominence ratio)
- Converting microphone sensitivity to CalibrationFactor
- User mentions PESQ or POLQA (redirect to correct alternatives)

## When NOT to Use

- Real-time streaming audio processing loops — use `matlab-process-streaming-audio`
- Audio device I/O, recording, or live `calibrateMicrophone` — use `matlab-play-record-audio`
- Audio plugin authoring (VST/AU) — use `matlab-write-audio-plugin`
- General filter design unrelated to measurement — use `matlab-design-digital-filter`
- Spatial audio / HRTF / SOFA processing

## Workflow

Follow this decision tree to route the user's goal to the right function:

### 1. Identify the measurement goal

| Goal | Category | Go to |
|------|----------|-------|
| "How loud is it?" (perceived) | Psychoacoustic | → Psychoacoustic Metrics |
| "Does it comply with broadcast loudness?" | Broadcast | → Broadcast Loudness |
| "Is the noise level acceptable for this space?" | Noise compliance | → Noise Compliance |
| "Can people understand speech in this room?" | Speech intelligibility | → STI/SII Measurement |
| "How good does processed speech sound?" | Speech quality | → Speech Quality |
| "What's the SPL?" | Level measurement | → SPL Measurement |
| "What's the reverberation time?" | Room acoustics | → RT60 |
| "Is there a tonal component?" | Tonality | → Tonality |

### 2. Ask before computing

Before writing code, confirm these with the user:

- **Calibration:** Do they have a CalibrationFactor? Did they calibrate with `calibrateMicrophone`? (See Calibration section)
- **Standard:** Which standard or method applies? (ISO 532-1 vs 532-2, NC vs RC vs RNC)
- **Sound field:** Free field or diffuse field recording?
- **Application context:** What space type? What's the concern? (Drives NC vs RC vs RNC selection)

### 3. Select function and apply

Use the Key Functions table and the category-specific patterns below.

## Functions That Do NOT Exist

| Function | Status | Use Instead |
|----------|--------|-------------|
| `pesq` | Does NOT exist (proprietary ITU-T P.862 license) | `visqol(degraded, reference, fs, Mode="speech")` |
| `polqa` | Does NOT exist (proprietary ITU-T P.863 license) | `visqol(degraded, reference, fs)` |

Never suggest `pesq` or `polqa`. They are not in Audio Toolbox and cannot be added due to licensing.

## Key Functions

| Function | Purpose | Standard | Available From |
|----------|---------|----------|----------------|
| `acousticLoudness` | Perceived loudness (sones) | ISO 532-1/2 | R2020a |
| `acousticSharpness` | Perceived sharpness (acum) | DIN 45692 | R2020a |
| `acousticRoughness` | Perceived roughness (asper) | — | R2021a |
| `acousticFluctuation` | Fluctuation strength (vacil) | — | R2020b |
| `integratedLoudness` | Broadcast loudness (LUFS) | EBU R 128 / ITU-R BS.1770 | R2016b |
| `loudnessMeter` | Streaming broadcast loudness meter | EBU R 128 / ITU-R BS.1770 | R2018a |
| `visqol` | Full-reference audio quality (MOS) | — | R2024a |
| `stoi` | Short-time objective intelligibility | — | R2024a |
| `mnru` | Modulated noise reference unit | ITU-T P.810 | R2024a |
| `dBov` | Power level relative to overload (dB) | ITU-T G.100.1 | R2024a |
| `speechTransmissionIndex` | STI from IR or test signals | IEC 60268-16 | R2026a |
| `speechIntelligibilityIndex` | SII from IR, test signals, or levels | ANSI/ASA S3.5-1997 | R2026b |
| `stipaExcitation` | Generate STI/STIPA test signals | IEC 60268-16 | R2026a |
| `siiExcitation` | Generate SII test signals | ANSI/ASA S3.5-1997 | R2026b |
| `noiseCriteria` | NC rating + SIL + spectrum imbalance + rattle risk | ANSI/ASA S12.2 | R2026b |
| `roomNoiseCriteria` | RNC rating (detects surging/fluctuations) | ANSI/ASA S12.2 | R2026b |
| `roomCriteria` | RC Mark II rating (HVAC systems) | ANSI/ASA S12.2 | R2026b |
| `noiseCriteriaCurves` | Look up NC curve values | ANSI/ASA S12.2 | R2026b |
| `noiseCriteriaRecommendations` | Recommended NC levels by room type | ANSI/ASA S12.2 | R2026b |
| `speechInterferenceLevel` | SIL from recording | ANSI/ASA S12.2 | R2026b |
| `rt60` | Reverberation time from impulse response | ISO 3382-1/2 | R2025a |
| `acousticToneToNoiseRatio` | Detect/quantify tones | ECMA-418-1 | R2023b |
| `acousticProminenceRatio` | Tonality via critical band comparison | ECMA-418-1 | R2023b |
| `splMeter` | SPL measurement (time-weighted, per-band) | IEC 61672 | R2018a |
| `calibrateMicrophone` | Compute calibration factor from known tone | — | R2018b |
| `weightingFilter` | A/C/Z/K frequency weighting | IEC 61672-1 | R2016b |
| `octaveFilter` | Single octave-band filter | ANSI S1.11-2004 | R2017b |
| `octaveFilterBank` | Multi-band octave filtering | ANSI S1.11-2004 | R2019a |

See `references/function-arguments.md` for complete argument lists, defaults, and valid values for each function — consult when constructing calls with non-default parameters.

## Calibration

### CalibrationFactor from microphone sensitivity

Convert dB sensitivity (dBV/Pa) to the linear CalibrationFactor:

```matlab
sensitivity_dBV = -26;  % Example: -26 dBV/Pa microphone
calibrationFactor = 1 / 10^(sensitivity_dBV/20);
```

The CalibrationFactor is the 3rd positional argument for `acousticLoudness`, `acousticSharpness`, `acousticRoughness`, and `acousticFluctuation` (default: `sqrt(8)`). For noise compliance functions, pass it as a name-value: `CalibrationFactor=value`.

### System-level calibration advice

Always ask the user about their signal chain. If the recording path includes a preamp, audio interface, or ADC with unknown gain, the mic sensitivity spec alone is insufficient. Recommend:

1. Play a 1 kHz tone through the system and record it through the full signal chain (mic → preamp → ADC → WAV). Use a pistonphone for a known 94 dB reference, or place a physical SPL meter next to the microphone to get an SPL reading.
2. Compute the system calibration factor: `calibrationFactor = calibrateMicrophone(calRecording, fs, SPLreading, FrequencyWeighting="Z-weighting")`
3. Pass that factor to the measurement function

`calibrateMicrophone` expects a 1 kHz tone recording as input. The `SPLreading` argument is the known SPL in dB (e.g., 94 from a pistonphone, or the value shown on a physical SPL meter).

Cross-reference: for the physical recording workflow with `calibrateMicrophone`, see the `matlab-play-record-audio` skill.

## Patterns

### Psychoacoustic Metrics

```matlab
[audioIn, fs] = audioread("recording.wav");
calFactor = 1 / 10^(-26/20);

loudness = acousticLoudness(audioIn, fs, calFactor, ...
    Method="ISO 532-1", SoundField="diffuse", TimeVarying=true);

sharpness = acousticSharpness(audioIn, fs, calFactor, ...
    SoundField="diffuse", TimeVarying=true);

roughness = acousticRoughness(audioIn, fs, calFactor, SoundField="diffuse");

fluctuation = acousticFluctuation(audioIn, fs, calFactor, SoundField="diffuse");
```

**Return types:** `acousticLoudness` returns a scalar (sones) for stationary analysis. With `TimeVarying=true`, it returns a column vector (time-varying loudness in sones). The second output (`specificLoudness`) is a matrix (time x critical bands). It does NOT return a struct or timetable.

**Ask the user:**
- ISO 532-1 (Zwicker, stationary/time-varying) or ISO 532-2 (Moore-Glasberg)?
- Free-field or diffuse-field recording?
- Time-varying analysis needed?

See `references/psychoacoustic-metrics.md` for method selection guidance (ISO 532-1 vs 532-2), interpretation tables (sone values, sharpness/roughness/fluctuation scales), tonality metric selection, and combined sound quality assessment workflows.

### Unit Conversions

Use built-in functions — do NOT reimplement conversion formulas manually:

| Conversion | Function | Method selection |
|------------|----------|-----------------|
| phon → sone | `phon2sone(phon, standard)` | `"ISO 532-1"` (default), `"ISO 532-2"` |
| sone → phon | `sone2phon(sone, standard)` | `"ISO 532-1"` (default), `"ISO 532-2"` |
| Hz → ERB | `hz2erb(freq)` | Single formula (no variants) |
| ERB → Hz | `erb2hz(erb)` | Single formula (no variants) |
| Hz → bark | `hz2bark(freq)` | Single formula (no variants) |
| bark → Hz | `bark2hz(bark)` | Single formula (no variants) |
| Hz → mel | `hz2mel(freq, MelStyle=s)` | `"oshaughnessy"` (default), `"slaney"` |
| mel → Hz | `mel2hz(mel, MelStyle=s)` | `"oshaughnessy"` (default), `"slaney"` |

When the user specifies a standard (e.g., "ISO 532-2"), pass it as the second positional argument for `phon2sone`/`sone2phon`. For `hz2mel`/`mel2hz`, use the `MelStyle` name-value pair.

### Noise Compliance

Choose the function based on the application:

| Situation | Function | Why |
|-----------|----------|-----|
| General background noise rating | `noiseCriteria` | Standard NC curves (ANSI/ASA S12.2) |
| HVAC system noise specifically | `roomCriteria` | RC Mark II designed for HVAC evaluation |
| Noise with audible surging/fluctuation | `roomNoiseCriteria` | RNC penalizes time-varying noise (requires ≥15 s recording) |
| Quick speech interference check | `speechInterferenceLevel` | Direct SIL value |
| Need recommended levels for room type | `noiseCriteriaRecommendations` | Lookup table by room use |

```matlab
[audioIn, fs] = audioread("office_noise.wav");

[NC, SIL, specImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
    CalibrationFactor=2.3);

SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=2.3);

rec = noiseCriteriaRecommendations("NC", Occupancy="all");
```

**Return types:**
- `NC` is a string (e.g., `"NC-35"` or `"NC-56 (1000 Hz)"` if a band exceeds)
- `RC` is a string (e.g., `"RC-32(N)"` — the letter indicates spectrum quality: N/R/H/RV)
- `SIL` and `LMF` are double scalars (dB)
- `QAI` is a double scalar (dB; 0 = ideal neutral)
- `specImbalance` and `rattleRisk` are structs with `.Summary` (string) and `.Details` (table) — access `.Summary` for display. **Exception:** `specImbalance` degrades to a `char` scalar (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15. Guard with `isstruct(specImbalance)` before dot-indexing.
- `noiseCriteriaRecommendations` requires a criteria name argument: `"NC"`, `"RNC"`, or `"RC"`

**Ask the user:**
- What type of space? (office, classroom, hospital, concert hall)
- Is the noise source HVAC? → prefer `roomCriteria`
- Is the noise steady or fluctuating? → if fluctuating, use `roomNoiseCriteria`

See `references/noise-compliance.md` for detailed output interpretation and selection guidance.

### Speech Quality

```matlab
[degraded, fs] = audioread("processed_speech.wav");
[reference, ~] = audioread("reference_speech.wav");

mosScore = visqol(degraded, reference, fs, Mode="speech");

intelligibility = stoi(degraded, reference, fs);
```

**Critical:** `stoi` and `visqol` argument order is `(processed, reference, fs)` — processed/degraded signal FIRST.

`visqol` modes: `"speech"` for narrowband/wideband speech (outputs 1-5 MOS), `"audio"` (default) for general audio.

### STI/SII Measurement

Two methods are available for both `speechTransmissionIndex` and `speechIntelligibilityIndex`:

**IR-based method** (simpler — no alignment needed):

```matlab
[ir, fs] = audioread("room_impulse_response.wav");
sti = speechTransmissionIndex(ir, fs);
sii = speechIntelligibilityIndex(ir, fs);
```

**Direct method** (from test signals transmitted through the system):

```matlab
fs = 48000;
reference = stipaExcitation(fs, Duration=15);
% Transmit reference through system, record as 'processed'
[processed, ~] = audioread("received_stipa.wav");

% IMPORTANT: Align signals before computing (see Signal Alignment)
processed = alignsignals(processed, reference);

sti = speechTransmissionIndex(processed, reference, fs);
```

**Ask the user:**
- Do they have an impulse response? → use IR method (simpler, no alignment needed)
- Measuring live? → generate test signal, transmit, record, align, compute
- STI or SII? STI for room/PA systems (IEC 60268-16); SII for hearing/communication (ANSI S3.5)

See `references/sti-measurement.md` for STI NV arguments, post-processing adjustment workflow (Annex M), test signal generation, and result interpretation. See `references/sii-measurement.md` for SII standard clause selection (5.1-5.3), BandImportanceFunction guidance, measurement positioning, and result interpretation.

### SPL Measurement (Offline)

```matlab
[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="Full band", ...
    FrequencyWeighting="A-weighting", ...
    TimeWeighting="fast", ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);

% For a single overall value, read the final row
fprintf("Leq: %.1f dB(A)\n", Leq(end));
```

Valid `Bandwidth` values: `"Full band"` (overall level), `"1 octave"`, `"2/3 octave"`, `"1/3 octave"`. There is no `"broadband"` option — use `"Full band"` for a single overall SPL value.

**Output arity:** All outputs (`Lt`, `Leq`, `Lpeak`, `Lmax`) have one row per input sample. For a 12-second file at 44.1 kHz, that is 539,648 rows. Never `fprintf` or `disp` the full output — it will hang. Instead:
- **Single overall value:** read `Leq(end)` (the final accumulated value)
- **Time-interval readings:** downsample to interval boundaries: `Leq(round(fs*T):round(fs*T):end, :)` where `T` is the desired interval in seconds

`TimeInterval` controls the integration window for `Leq` computation but does NOT reduce the number of output rows.

Do not manually compute `20*log10(rms(audioIn)/20e-6)` — `splMeter` handles calibration, weighting, and time integration correctly per IEC 61672.

**Multi-band (octave-band) SPL:** Use `splMeter` with `Bandwidth="1 octave"` — do NOT use `octaveFilterBank` + manual dB conversion. Key properties for octave-band SPL:

```matlab
[audioIn, fs] = audioread("recording.wav");

spl = splMeter(SampleRate=fs, ...
    Bandwidth="1 octave", ...
    FrequencyWeighting="Z-weighting", ...
    TimeWeighting="fast", ...
    FrequencyRange=[15 8000], ...
    OctaveFilterOrder=8, ...
    CalibrationFactor=2.3);

[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
cf = getCenterFrequencies(spl);
```

**Critical gotchas for octave-band `splMeter`:**

- **Property name is `OctaveFilterOrder`** (not `FilterOrder`). `FilterOrder` does not exist on `splMeter`.
- **`FrequencyRange` compares against true center frequencies** (`fc = 1000 × 10^(3b/10)` per IEC 61260), not nominal values. A band is included only if its true center falls within `[lower, upper]`. Bands below 1 kHz have true centers slightly above nominal (e.g., "63 Hz" = 63.10); bands above 1 kHz have true centers below nominal (e.g., "2 kHz" = 1995.26, "8 kHz" = 7943.28). Use `floor(true_center)` for lower bounds and `ceil(true_center)` for upper bounds. Common case "16 Hz to 8 kHz": use `[15 8000]` — the 16 Hz true center is 15.85 (so 15 ≤ 15.85 includes it) and 8 kHz true center is 7943 (so 8000 ≥ 7943 includes it). Do NOT use `[16 8000]` — this drops the 16 Hz band.
- **Output is per-sample** (see Output arity note above). Never print the full output. For time-interval readings, downsample: `Lt100ms = Lt(round(fs*0.1):round(fs*0.1):end, :);`

See `references/spl-measurement.md` for weighting selection guidance (A/C/Z and fast/slow), SPL interpretation tables, occupational exposure limits, splMeter vs poctave equivalency, and common measurement scenarios.

### Broadcast Loudness (EBU R 128)

```matlab
[audioIn, fs] = audioread("broadcast_content.wav");
[loudness, loudnessRange] = integratedLoudness(audioIn, fs);

% Check compliance: target is -23 LUFS +/- 1 LU
isCompliant = abs(loudness - (-23)) <= 1;
```

Use `integratedLoudness` for offline compliance checks. Use `loudnessMeter` for streaming/real-time monitoring (see `matlab-process-streaming-audio`).

### RT60

```matlab
[ir, fs] = audioread("room_ir.wav");
rtsummary = rt60(ir, fs, Bandwidth="1 octave");
```

**Ask the user:**
- What is the room type? (drives the target RT60)
- Do they have an IR, or do they need to measure one?
- T30 (standard) vs T20 (when noise floor limits dynamic range)?

See `references/rt60-measurement.md` for target RT60 values by space type, T20/T30/EDT interpretation, frequency-dependent analysis, and relationship to STI.

### Tonality

```matlab
[audioIn, fs] = audioread("machine_noise.wav");

[tnr, tnrFreq, isProminent] = acousticToneToNoiseRatio(audioIn, fs);

[pr, prFreq, isProminent] = acousticProminenceRatio(audioIn, fs);
```

All outputs are empty (0×1) when no tonal components are detected. Check `isempty(tnr)` before indexing.

### Standards-Compliant Filters (Custom Preprocessing)

The metric functions above perform standards-compliant filtering internally. Use standalone filter objects only for custom measurement workflows where no single metric function applies AND you do not need SPL output:

```matlab
% A-weighting filter
wf = weightingFilter("A-weighting", fs);
weightedSignal = wf(audioIn);

% Octave-band filter bank (for waveform-level band decomposition only)
ofb = octaveFilterBank("1 octave", fs, ...
    FrequencyRange=[31.5 16000], FilterOrder=8);
bandSignals = ofb(audioIn);
```

**If you need octave-band SPL levels**, use `splMeter` with `Bandwidth="1 octave"` instead of `octaveFilterBank` + manual dB conversion. See the Multi-band SPL section above.

## Signal Alignment

| Function | Internal alignment? | Action |
|----------|-------------------|--------|
| `visqol` | Yes | No action needed |
| `stoi` | No | Align before calling |
| `speechTransmissionIndex` | No | Align for direct method; IR method avoids issue |
| `speechIntelligibilityIndex` | No | Align for direct method; IR method avoids issue |

For the direct `(processed, reference, fs)` method, always align signals:

```matlab
processed = alignsignals(processed, reference);
```

SII is more sensitive to misalignment than STI. At 50 ms delay: SII error ~0.016, STI negligible. At 200 ms: SII ~0.036, STI ~0.017. The IR-based `(ir, fs)` method avoids alignment issues entirely.

## Common Mistakes

| Mistake | Why it fails | Correct approach |
|---------|-------------|-----------------|
| Call `pesq(reference, degraded, fs)` | Function does not exist | `visqol(degraded, reference, fs, Mode="speech")` |
| `stoi(reference, processed, fs)` | Wrong argument order | `stoi(processed, reference, fs)` — processed FIRST |
| `acousticFluctuationStrength(...)` | Wrong function name | `acousticFluctuation(audioIn, fs, calFactor)` |
| Implement NC from scratch with hardcoded curves | Misses SIL, spectrum imbalance, rattle risk | `noiseCriteria(audioIn, fs, CalibrationFactor=cf)` |
| `20*log10(rms(x)/20e-6)` for SPL | No weighting, no time integration, no calibration | `splMeter` with appropriate settings |
| Implement STI algorithm manually | ~100 lines, error-prone, misses NV options | `speechTransmissionIndex(ir, fs)` |
| Divide signal by calibration factor manually | Incorrect; factor is a multiplier, not a divisor | Pass as positional arg or `CalibrationFactor=value` |
| Skip alignment for direct STI/SII | Silent accuracy degradation | `alignsignals(processed, reference)` before calling |
| Use `acousticLoudness` for broadcast loudness | Wrong standard (ISO 532 = sones, not LUFS) | `integratedLoudness` for EBU R 128 compliance |
| `string(rattleRisk)` or `fprintf("%s", specImbalance)` | These are structs, not strings | Access `.Summary` field: `rattleRisk.Summary` |
| `specImbalance.Summary` when NC is out of curve range | `specImbalance` degrades to `char` (not struct) when "Above NC-70" or below NC-15 | Guard: `if isstruct(specImbalance), disp(specImbalance.Summary); end` |
| `roomNoiseCriteria` on recordings shorter than 15 s | ANSI/ASA S12.2-2019 requires ≥150 Lt samples at 100 ms intervals | Ensure recording is at least 15 seconds; use `noiseCriteria` for shorter clips |
| `round(NC)` or arithmetic on NC/RC output | NC and RC are strings, not numbers | Use directly: `fprintf("%s\n", NC)` |
| `noiseCriteriaRecommendations()` with no args | First argument (criteria name) is required | `noiseCriteriaRecommendations("NC")` |
| `loudness.OverallLoudness` after `acousticLoudness` | Returns a scalar or vector, not a struct | Use directly: `fprintf("%.1f sones\n", loudness)` |
| `splMeter(..., FilterOrder=8)` | Property does not exist on `splMeter` | Use `OctaveFilterOrder=8` |
| `splMeter(..., FrequencyRange=[16 8000])` for 16 Hz–8 kHz | Drops 16 Hz band (true center is 15.85 Hz, which is below 16) | Use `FrequencyRange=[15 8000]` — use `floor(true_center)` for lower bound |
| `octaveFilterBank` + `20*log10(rms(band)/pRef)` for SPL | Manual, no time weighting, no calibration integration | Use `splMeter` with `Bandwidth="1 octave"` |
| Treating `splMeter` output as a single value | All outputs have one row per input sample (e.g., 539k rows for 12s at 44.1 kHz) | Use `Leq(end)` for a single value, or downsample to interval boundaries |

## Conventions

- Always ask about the user's measurement goal before selecting a function
- Always ask about calibration — recommend `calibrateMicrophone` for system-level accuracy
- Default to `SoundField="free"` for anechoic/outdoor, `"diffuse"` for reverberant rooms
- Default to `Method="ISO 532-1"` for loudness (Zwicker method, most common)
- Use IR-based methods for STI/SII when an impulse response is available (avoids alignment)
- Pass `CalibrationFactor` explicitly rather than pre-scaling the signal
- For noise compliance, prefer `roomCriteria` for HVAC and `noiseCriteria` for general background noise

----

Copyright 2026 The MathWorks, Inc.

----