# Ir Drop Triage

> Triage static and dynamic IR-drop and electromigration (EM) reports from power signoff tools (Voltus, RedHawk, PrimePower). Use when the user says "IR drop", "power grid", "dynamic voltage drop", "electromigration", "EM violation", "hotspot", "power signoff".

- Skill: `vibeic/ir-drop-triage` (Agent Skill, multi-file: 4 files)
- Install (CLI): `npx get-skill add vibeic/ir-drop-triage`
- Raw SKILL.md: https://api.skillmd.com/api/skills/vibeic/ir-drop-triage/raw
- Safety review: pending
- Works with: Claude Code, Claude.ai, OpenAI Codex
- Category: Coding & Dev Tools
- Author: vibeic (https://skillmd.com/u/vibeic)
- Updated: 2026-11-15
- Page: https://skillmd.com/skills/vibeic/ir-drop-triage

---


# IR-Drop / EM Triage

Power integrity failures can turn a timing-clean chip into a field failure. This skill reads native IR-drop and EM reports, pinpoints hot regions, and proposes power-grid fixes. The native tool result against its original limit determines signoff.

## When to use

- After initial power grid insertion
- After placement (static IR)
- After routing + SDF back-annotation (dynamic IR)
- Whenever tapeout checklist flags an EM-density violation

## Inputs

1. IR-drop report (static + dynamic)
2. EM report (current density per metal layer)
3. Power grid definition
4. Switching activity file (VCD, SAIF, or propagation from simulation)
5. Floorplan with macro/standard-cell placement

## Workflow

1. **Hotspot map + budget pass/fail** — DETERMINISTIC, enforced by
   `programs/ir_drop_budget_check.py`. It computes `budget_mV = pct·Vdd·1000`
   (the 5–10%-of-Vdd budget; 10% permissive default) and FAILs iff the
   worst-case measured drop ≥ budget. Do NOT re-derive the budget by hand —
   call the program.
2. **Classify the measured cause.** Inspect the native voltage/current map,
   grid connectivity, via arrays, strap pitch, metal width and switching
   activity at each hotspot. Separate sparse straps, narrow metal, weak via
   connections and local switching demand using the tool's actual data.
3. **Choose a physical fix.** Add straps or vias, widen metal, add decoupling,
   or reduce local switching demand when the measured cause supports it.
   Rerun native IR and EM analysis against the same original budgets.

## Native PDN implementation choices

Read the failing segment's layer, coordinates, current, cross-section and
original limit from the native EM report. Distinguish a metal-width violation
from a per-cut via violation before choosing a repair. A width-scaled utilization
is only a prediction; rebuilding the grid can redistribute current.

For the native flow, use `programs/flow_config.py --project <project> --route ic
--set KEY=JSON` to record the selected `PDN_*` setting. The program preserves
other choices in the existing `plugin_output/declaration.json` and emits the
configuration that consumes the move. This is an implementation choice, not a
new specification limit or a required declaration contract. Do not change the
user's prompt or generated L documents to express it.

Keep the original report and the rollback value. Resume through the public
entry from PDN generation, then remeasure EM, IR, timing and physical verification
with their original limits. A changed declaration alone does not invalidate a
retained result or establish that the candidate ran.

## Output format

- `power/ir_triage.md`:
  - Hotspot table with coordinates, cell, drop %, fix
  - EM violation table with metal layer, current density, fix
  - P&R script snippets (strap insertion, decap placement)
  - Estimated impact on routing congestion

## Technical basis

Power integrity references: Tan & Roy "On-Chip Power Delivery and Management". Commercial signoff: Ansys RedHawk, Cadence Voltus, Synopsys PrimePower. Open-source: OpenROAD `psm` (PDN analysis).

## Handoff

- PDN changes → `/flow-orchestrate` to re-run PDN + route
- Timing impact of sizing changes → `/sta-review`
- Decap placement → `/placement-optimize`

## Captured rule

Read the native EM report's layer, coordinates, current, cut count, area and
original current-density limit before choosing a repair. A small IR drop does
not clear an overloaded via array. For a via-array bottleneck, use the native
PDN geometry options through `flow_config.py` to widen the landing or provide
more connections, then regenerate PDN and rerun the affected routing, timing,
physical checks, IR and EM against their original limits. Preserve a proven
design requirement in its own input documents so Phase 1 carries it into L19;
do not make one measured width a global default or use a hand-set declaration
as proof of document ingestion.

An EM via-array bottleneck is not repaired by IR drop alone. Subservient's native
Classic reference had only low IR drop but514 EM violations /664.63% utilization
at the original100% limit. A wider landing alone still failed313/390.73%; retain
that failure. Derive denser template-grid proposals from measured native EM,
then let original native EM/DRC/routing/timing decide. Include native CTS/slew
choices when clock power/fanout remains a constraint; do not waive fanout1 just
because33 earlier rows PASS. The program-derived eligible complete candidate
measured EM0/69.98%, DRC/LVS0 and44/44 native rows PASS on image0.4.76. The actual
proposer/selector (not a hand setting or this lesson) captures the recovery.

## Captured rule

Before changing a power grid for a via electromigration failure, read what the
report compared. A foundry states a via limit as a current per cut; a density
over the cut area against that same number is a different, far stricter rule.
The native report says which it used ("Vias judged per cut", and the basis
column of the per-segment rows). When a PDK's cut limits are per via, its cited
per-via table belongs in `programs/pdk_registry.json` (`em_current_limits`,
with source, temperature and cut size), and the same per-cut comparison then
serves every design on that PDK. Measured on SKY130 (the technology LEF says
"mA per via"): a hard macro's rail-to-strap crossings carried at most 0.109 mA
through 10 cuts. Read as a density that was 19 violations, worst 166.44 %; per
cut it is 3.7 % of the 0.29 mA limit, and the row passed with 0 violations,
worst 8.08 % (met1), on identical segment currents. The limit itself is
unchanged. Widening the straps does not address such a finding.

## Captured rule

A connected, unloaded power grid can have a valid native PSM solution with
solved supply voltages and zero load current. An empty load-current map does
not invalidate that solution. Judge IR drop and electromigration from the
native reports against the original limits. Do not invent a load to obtain a
solution or waive an unmeasured result.

An unloaded-grid result does not establish loaded-grid performance. Include
the design's actual power demand when evaluating loaded IR drop and EM.