Role
This skill owns WLS process lifecycle, worker stability, reload and restart behavior, and runtime-safe process control. It protects long-running runtime behavior and avoids changes that would destabilize workers or orchestration.
When To Use
- Use for WLS lifecycle issues, workers, dispatcher behavior, process cleanup, reload versus restart, and runtime process orchestration.
- Use for keywords such as WLS, worker, dispatcher, process,
server:start,server:reload,server:restart, and lifecycle. - Use when the bug or change is runtime-sensitive and affects long-lived execution.
Source Material
AI-ENTRY.mdCLAUDE.mddev/ai/skills/weline-framework-runtime/SKILL.mddev/ai/skills/runtime-and-process/SKILL.mddev/ai/skills/windows-command-quoting/SKILL.mddev/ai/skills/code-generation-standards/SKILL.md
Responsibilities
- Diagnose runtime issues through lifecycle-aware reasoning instead of one-off process killing.
- Choose reload or restart correctly based on the affected runtime surface.
- Keep process cleanup explicit and safe.
- Preserve worker responsiveness and avoid blocking behavior in runtime-sensitive code.
Workflow
- Read
AI-ENTRY.md, runtime docs, and the relevant WLS skill material before touching process code. - Identify whether the problem is business-code reloadable, startup-parameter sensitive, or orchestration-specific.
- Trace the affected lifecycle path through worker, dispatcher, orchestrator, or master behavior.
- Before using hot reload or restart as evidence, confirm a matching WLS instance is actually running; otherwise switch to non-runtime bootstrap/collect checks and report the runtime gap honestly.
- Implement the smallest stable runtime change in the owning process path.
- Validate with a dedicated WLS test instance on port
9502+using a unique name. - Stop the dedicated WLS test instance after automated validation, unless user manual acceptance is required.
- If manual acceptance is required, keep the dedicated instance running and report URL, instance name, port, status, and exact stop command; stop it after the user confirms acceptance.
- Report lifecycle impact, validation steps, and cleanup or manual-acceptance handoff.
Weline Rules
- Do not use default WLS port
9501for AI testing. - Always start a dedicated WLS test instance on port
9502+. - Always use a unique AI test instance name.
- Stop the AI test instance after automated validation.
- If user manual acceptance is required, keep only the dedicated
ai-test-*instance running and hand off URL/name/port/status/stop command until the user confirms acceptance. - Do not reuse test instance names.
- Do not leave unmanaged test instances running.
- Do not use
sleep,die, orexitinside WLS runtime-sensitive code. - Do not introduce or rely on global variables or process-wide mutable global state in framework/runtime code;
$_SERVERis only allowed in Fiber/WLS request context assembly, and all other code must useWelineEnv,w_env*, request objects, or explicitContext; context assembly must hand off explicit Context, request, session, or service objects before WLS workers handle requests. - Do not treat
setup:upgrade --hot,server:reload, or similar commands as proof if no target WLS instance was alive to receive them. - For hot-path performance work, keep cache boundaries away from request-, user-, session-, cart-, auth-, permission-, language-, currency-, and current-query-dependent state unless those dimensions are explicitly represented in the cache key.
- If Browser-visible performance is the target, re-measure on the dedicated runtime after reload/restart and confirm that the optimization did not break account/sidebar/language or other user-scoped behavior.
Inputs Required
- The runtime symptom, logs, and affected lifecycle stage.
- The owning process or runtime component.
- Whether the change affects reloadable code, startup parameters, or shared services.
- The validation instance name and port plan.
Expected Output
- A runtime-safe change to the owning WLS process path.
- Evidence from a dedicated WLS test instance.
- Confirmation that the test instance was stopped after automated validation, or a manual-acceptance handoff with URL, instance name, port, status, and stop command.
Validation
- Start a unique dedicated test instance on port
9502+. - Use reload for normal code-path validation and restart only when lifecycle conditions require it.
- Confirm worker behavior, cleanup, and stability after the change.
- Stop the dedicated test instance after automated validation and verify no stray instance is left running.
- For user manual acceptance, keep the dedicated instance running only with an explicit handoff and stop it after acceptance.
- If runtime validation could not happen because the instance was absent, record the exact missing instance state and the fallback bootstrap/CLI evidence used instead.
Constraints
- Do not validate on port
9501. - Do not kill ports or processes blindly when lifecycle-aware cleanup is required.
- Do not introduce blocking calls into runtime-sensitive worker code.
- Do not leave unmanaged runtime test instances behind after the session; user-acceptance handoff instances must be explicitly named, reachable, and paired with a stop command.
Shared Collaboration Contract
This specialist skill must follow 通用工程师-开发规范与代码质量 as the shared engineering and collaboration standard.
Before and during work:
- Know the Weline AI agent roster defined in the shared skill and
dev/ai/agent/README.md. - Keep work inside this specialist's ownership boundary.
- When a problem, blocker, risk, validation failure, or cross-agent issue is found, notify
@Weline-技术主管. - Do not silently expand scope to fix another agent's area.
- Include collaboration status in the final report.