Opentrons Integration
Overview
Opentrons is a Python-based lab automation platform for Flex and OT-2 robots. Write Protocol API v2 protocols for liquid handling, control hardware modules (heater-shaker, thermocycler), manage labware, for automated pipetting workflows.
When to Use This Skill
This skill should be used when:
- Writing Opentrons Protocol API v2 protocols in Python
- Automating liquid handling workflows on Flex or OT-2 robots
- Controlling hardware modules (temperature, magnetic, heater-shaker, thermocycler)
- Setting up labware configurations and deck layouts
- Implementing complex pipetting operations (serial dilutions, plate replication, PCR setup)
- Managing tip usage and optimizing protocol efficiency
- Working with multi-channel pipettes for 96-well plate operations
- Simulating and testing protocols before robot execution
Core Capabilities
1. Protocol Structure and Metadata
Every Opentrons protocol follows a standard structure:
from opentrons import protocol_api
# Metadata
metadata = {
'protocolName': 'My Protocol',
'author': 'Name <email@example.com>',
'description': 'Protocol description',
'apiLevel': '2.19' # Pin to a level your robot's app/firmware accepts
}
# Requirements (optional). When present, apiLevel here takes precedence over the
# value in metadata, and robotType is required for Flex.
requirements = {
'robotType': 'Flex', # or 'OT-2'
'apiLevel': '2.19'
}
# Run function
def run(protocol: protocol_api.ProtocolContext):
# Protocol commands go here
pass
Key elements:
- Import
protocol_apifromopentrons - Define
metadatadict with protocolName, author, description, apiLevel - Optional
requirementsdict for robot type and API version - Implement
run()function receivingProtocolContextas parameter - All protocol logic goes inside the
run()function
2. Loading Hardware
Loading Instruments (Pipettes):
def run(protocol: protocol_api.ProtocolContext):
# Load pipette on specific mount
left_pipette = protocol.load_instrument(
'flex_1channel_1000', # Instrument name (Flex convention)
'left', # Mount: 'left' or 'right'
tip_racks=[tip_rack] # List of tip rack labware objects
)
Common pipette load names (these are the exact instrument_name strings — do NOT invent
p1000_single_flex-style names; Flex uses the flex_<channels>_<volume> convention):
- Flex:
flex_1channel_50,flex_1channel_1000,flex_8channel_50,flex_8channel_1000,flex_96channel_1000 - OT-2:
p20_single_gen2,p300_single_gen2,p1000_single_gen2,p20_multi_gen2,p300_multi_gen2
Loading Labware:
# Load labware directly on deck
plate = protocol.load_labware(
'corning_96_wellplate_360ul_flat', # Labware API name
'D1', # Deck slot (Flex: A1-D3, OT-2: 1-11)
label='Sample Plate' # Optional display label
)
# Load tip rack
tip_rack = protocol.load_labware('opentrons_flex_96_tiprack_1000ul', 'C1')
# Load labware on adapter
adapter = protocol.load_adapter('opentrons_flex_96_tiprack_adapter', 'B1')
tips = adapter.load_labware('opentrons_flex_96_tiprack_200ul')
Loading Modules:
# Temperature module (Flex + OT-2)
temp_module = protocol.load_module('temperature module gen2', 'D3')
temp_plate = temp_module.load_labware('corning_96_wellplate_360ul_flat')
# Heater-Shaker module (Flex + OT-2)
hs_module = protocol.load_module('heaterShakerModuleV1', 'D1')
hs_plate = hs_module.load_labware('corning_96_wellplate_360ul_flat')
# Thermocycler module (takes up specific slots automatically)
tc_module = protocol.load_module('thermocyclerModuleV2')
tc_plate = tc_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
# Magnetic Module (OT-2 ONLY) — an active, motorized module. Flex does not
# support it; on Flex use the unpowered Magnetic Block instead (see below).
mag_module = protocol.load_module('magnetic module gen2', '1') # OT-2 numeric slot
mag_plate = mag_module.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
# Magnetic Block (Flex ONLY) — unpowered; labware is moved on/off it with the
# Gripper. There is no engage/disengage; it has no motors.
mag_block = protocol.load_module('magneticBlockV1', 'C2')
block_plate = mag_block.load_labware('nest_96_wellplate_100ul_pcr_full_skirt')
3. Liquid Handling Operations
Basic Operations:
# Pick up tip
pipette.pick_up_tip()
# Aspirate (draw liquid in)
pipette.aspirate(
volume=100, # Volume in µL
location=source['A1'] # Well or location object
)
# Dispense (expel liquid)
pipette.dispense(
volume=100,
location=dest['B1']
)
# Drop tip
pipette.drop_tip()
# Return tip to rack
pipette.return_tip()
Complex Operations:
# Transfer (combines pick_up, aspirate, dispense, drop_tip)
pipette.transfer(
volume=100,
source=source_plate['A1'],
dest=dest_plate['B1'],
new_tip='always' # 'always', 'once', or 'never'
)
# Distribute (one source to multiple destinations)
pipette.distribute(
volume=50,
source=reservoir['A1'],
dest=[plate['A1'], plate['A2'], plate['A3']],
new_tip='once'
)
# Consolidate (multiple sources to one destination)
pipette.consolidate(
volume=50,
source=[plate['A1'], plate['A2'], plate['A3']],
dest=reservoir['A1'],
new_tip='once'
)
Advanced Techniques:
# Mix (aspirate and dispense in same location)
pipette.mix(
repetitions=3,
volume=50,
location=plate['A1']
)
# Air gap (prevent dripping)
pipette.aspirate(100, source['A1'])
pipette.air_gap(20) # 20µL air gap
pipette.dispense(120, dest['A1'])
# Blow out (expel remaining liquid)
pipette.blow_out(location=dest['A1'].top())
# Touch tip (remove droplets on tip exterior)
pipette.touch_tip(location=plate['A1'])
Flow Rate Control:
# Set flow rates (µL/s)
pipette.flow_rate.aspirate = 150
pipette.flow_rate.dispense = 300
pipette.flow_rate.blow_out = 400
4. Accessing Wells and Locations
Well Access Methods:
# By name
well_a1 = plate['A1']
# By index
first_well = plate.wells()[0]
# All wells
all_wells = plate.wells() # Returns list
# By rows
rows = plate.rows() # Returns list of lists
row_a = plate.rows()[0] # All wells in row A
# By columns
columns = plate.columns() # Returns list of lists
column_1 = plate.columns()[0] # All wells in column 1
# Wells by name (dictionary)
wells_dict = plate.wells_by_name() # {'A1': Well, 'A2': Well, ...}
Location Methods:
# Top of well (default: 1mm below top)
pipette.aspirate(100, well.top())
pipette.aspirate(100, well.top(z=5)) # 5mm above top
# Bottom of well (default: 1mm above bottom)
pipette.aspirate(100, well.bottom())
pipette.aspirate(100, well.bottom(z=2)) # 2mm above bottom
# Center of well
pipette.aspirate(100, well.center())
5. Hardware Module Control
Control temperature, magnetic, heater-shaker, thermocycler, and absorbance-reader modules. Each module context exposes its own set / wait / deactivate methods plus status properties (e.g. temp_module.set_temperature, hs_module.set_and_wait_for_shake_speed, tc_module.execute_profile). On Flex, the active Magnetic Module is replaced by the unpowered Magnetic Block (magneticBlockV1).
Full per-module code recipes (Temperature, Magnetic Module vs Flex Magnetic Block, Heater-Shaker, Thermocycler PCR cycling, Absorbance Plate Reader): see references/hardware_modules.md. The corresponding method/property tables are in references/api_reference.md.
6. Liquid Tracking and Labeling
Define Liquids:
# Define liquid types
water = protocol.define_liquid(
name='Water',
description='Ultrapure water',
display_color='#0000FF' # Hex color code
)
sample = protocol.define_liquid(
name='Sample',
description='Cell lysate sample',
display_color='#FF0000'
)
Load Liquids into Wells:
# Load liquid into specific wells
reservoir['A1'].load_liquid(liquid=water, volume=50000) # µL
plate['A1'].load_liquid(liquid=sample, volume=100)
# Mark wells as empty
plate['B1'].load_empty()
7. Protocol Control and Utilities
Execution Control:
# Pause protocol
protocol.pause(msg='Replace tip box and resume')
# Delay
protocol.delay(seconds=60)
protocol.delay(minutes=5)
# Comment (appears in logs)
protocol.comment('Starting serial dilution')
# Home robot
protocol.home()
Conditional Logic:
# Check if simulating
if protocol.is_simulating():
protocol.comment('Running in simulation mode')
else:
protocol.comment('Running on actual robot')
Rail Lights (Flex only):
# Turn lights on
protocol.set_rail_lights(on=True)
# Turn lights off
protocol.set_rail_lights(on=False)
8. Multi-Channel and 8-Channel Pipetting
When using multi-channel pipettes:
# Load 8-channel pipette
multi_pipette = protocol.load_instrument(
'p300_multi_gen2',
'left',
tip_racks=[tips]
)
# Access entire column with single well reference
multi_pipette.transfer(
volume=100,
source=source_plate['A1'], # Accesses entire column 1
dest=dest_plate['A1'] # Dispenses to entire column 1
)
# Use rows() for row-wise operations
for row in plate.rows():
multi_pipette.transfer(100, reservoir['A1'], row[0])
9. Common Protocol Patterns
Reusable end-to-end templates cover the most common workflows: serial dilution (diluent fill plus mix-after cascade across a row), plate replication (whole-plate wells()-to-wells() copy), and PCR setup (master-mix distribute, per-sample transfer, thermocycler cycling).
Full worked-example protocols for each pattern: see references/protocol_patterns.md. Runnable .py versions are in the scripts/ directory (serial_dilution_template.py, basic_protocol_template.py, pcr_setup_template.py).
Best Practices
- Always specify API level: Pin a stable
apiLevelyour robot's app/firmware supports (runopentrons_simulateto confirm); do not blindly use a number higher than the robot accepts - Use meaningful labels: Label labware for easier identification in logs
- Check tip availability: Ensure sufficient tips for protocol completion
- Add comments: Use
protocol.comment()for debugging and logging - Simulate first: Always test protocols in simulation before running on robot
- Handle errors gracefully: Add pauses for manual intervention when needed
- Consider timing: Use delays when protocols require incubation periods
- Track liquids: Use liquid tracking for better setup validation
- Optimize tip usage: Use
new_tip='once'when appropriate to save tips - Control flow rates: Adjust flow rates for viscous or volatile liquids
Troubleshooting
Common Issues:
- Out of tips: Verify tip rack capacity matches protocol requirements
- Labware collisions: Check deck layout for spatial conflicts
- Volume errors: Ensure volumes don't exceed well or pipette capacities
- Module not responding: Verify module is properly connected and firmware is updated
- Inaccurate volumes: Calibrate pipettes and check for air bubbles
- Protocol fails in simulation: Check API version compatibility and labware definitions
Resources
For detailed API documentation, see references/api_reference.md in this skill directory.
For example protocol templates, see scripts/ directory.