Active Disturbance Rejection Control (gnc-autonomy/control/active-disturbance-rejection-control)
Use when the task is linear active disturbance rejection control (ADRC) of a second-order plant whose internal dynamics and external disturbance are both unknown and lumped together as one total disturbance: a third-order linear extended state observer (LESO) estimates the state and the total disturbance from the measured output alone, and the control law cancels the disturbance estimate so the plant channel behaves as an ideal double integrator under a bandwidth-parameterized PD outer loop. The observer gains and the outer-loop gains are always fixed closed forms of two bandwidths, omega_o and omega_c, never tuned or adapted online. It pairs with gnc-autonomy/control/observer-design, whose full-order Luenberger estimator is designed for a known LTI plant at arbitrary poles rather than an augmented disturbance state at a fixed bandwidth, and with gnc-autonomy/control/adaptive-control and gnc-autonomy/control/l1-adaptive-control, whose gains or adaptive signals update online against an unknown plant coefficient rather than reconstruct a total disturbance at fixed observer poles.
Domain quick reference
- Design plant: canonical second-order y_ddot = f(y, y_dot, w) + b0 u with f the total disturbance (internal dynamics plus external disturbance, lumped and unknown to the controller) and b0 the given control-effectiveness estimate (b0 != 0 required).
- LESO (third order, augmented with the disturbance state z3 = f): z1_dot = z2 + beta1 (y - z1), z2_dot = z3 + beta2 (y - z1) + b0 u, z3_dot = beta3 (y - z1); only the output y is measured.
- Bandwidth parameterization (observer gains): beta1 = 3 omega_o, beta2 = 3 omega_o^2, beta3 = omega_o^3, making the error-dynamics characteristic polynomial s^3 + beta1 s^2 + beta2 s + beta3 = (s + omega_o)^3, all observer error poles at -omega_o.
- Disturbance-rejection control: u = (u0 - z3)/b0. With the converged estimate z3 = f the plant channel collapses to the exact double integrator y_ddot = f + b0 ((u0 - z3)/b0) = u0.
- Outer loop (bandwidth-parameterized PD on the estimated states): u0 = kp (r - z1) - kd z2 with kp = omega_c^2, kd = 2 omega_c, placing the ideal-loop tracking poles at -omega_c (double).
- Practical bandwidth ratio: omega_o = 6 omega_c in the worked design, inside the 4-10x band that keeps the observer fast enough to track the disturbance without amplifying measurement noise.
- Truth plant (simulator bookkeeping only, never a controller input): y_ddot = -A1 y_dot - A0 y + w(t) + b u with the true gain b, so the simulator-truth total disturbance is f = -A1 y_dot - A0 y + w(t).
- Units are SI throughout: rad/s for the bandwidths, dimensionless for b0 and the true gain b, seconds for time.
Workflow
- Fix the design plant and gains: pick the control-effectiveness estimate b0, the controller bandwidth omega_c and the observer bandwidth omega_o (omega_o must exceed omega_c), and confirm the bandwidth parameterization with observer_gains and controller_gains.
- Confirm the LESO characteristic-polynomial identity with char_poly_residual at sample points, verifying all three observer error poles sit at -omega_o (the (s + omega_o)^3 expansion).
- Run the closed-loop simulation with simulate_adrc: the third-order linear extended state observer estimates the state and the total disturbance z3 from the measured output y alone, on the truth plant with a disturbance step.
- Read the disturbance-rejection control law u = (u0 - z3)/b0 and audit the cancellation with cancellation_residual at the phase fixed points, the algebraic witness that z3 = f collapses the loop to the ideal double integrator.
- Inspect the tracking-error, command and total-disturbance-estimate histories across the reference start and the disturbance step, checking the settled-window residuals (max_abs_e_settle, max_z3_res_settle).
- Compare against the ideal perfect-cancellation loop with simulate_ideal to isolate the observer-lag cost of the finite bandwidth from the plant response itself.
- Run the mismatch robustness case (plant_b != b0) and confirm the output still settles at the reference while the estimate carries the fixed bias (b - b0) u.
- Confirm the deterministic checks with the contract test scripts/test_active_disturbance_rejection_control.py.
Worked example
Plant: second-order y_ddot = f(y, y_dot, w) + b0 u with the design gain estimate b0 = 1.0; simulator truth y_ddot = -0.75 y_dot - 0.5 y + w(t)
- b u with the external disturbance w = 0.5 for t < 3.0 s and w = 1.5 for t >= 3.0 s (a +1.0 step at 3.0 s) and the true gain b = 1.0 (worked, matched) or b = 0.8 (robustness, a 25 percent over-modeled control effectiveness). Design: controller bandwidth omega_c = 5.0 rad/s, observer bandwidth omega_o = 30.0 rad/s (six times omega_c), so kp = 25.0 and kd = 10.0 place the tracking poles at -5 (double) and beta = (90.0, 2700.0, 27000.0) place the observer error poles at -30 (triple). Reference r = 1.0 constant, initial state y(0) = 0, v(0) = 0, LESO from the zero estimate z(0) = (0, 0, 0). Forward Euler at dt = 1e-4 s over a 6.0 s horizon (60001 samples). All values below are real outputs of scripts/active_disturbance_rejection_control_logic.py:
- Bandwidth parameterization: observer_gains(30.0) = (90.0, 2700.0, 27000.0); controller_gains(5.0) = (25.0, 10.0); char_poly_residual is 0.000e+00 at s = -30, -3, -1 and 0.5.
- Fixed points of the cancelled loop (y = r = 1.0, v = 0, u0 = 0): phase 1 (w = 0.5) f = 0.0, z3 = 0.0, u = 0.0; phase 2 (w = 1.5) f = 1.0, z3 = 1.0, u = -1.0; cancellation_residual is 0.000e+00 at both.
- Worked run (b = b0 = 1.0): y(0.2) = 0.259669337601, y(0.5) = 0.705882336870, y(1.0) = 0.963564880347, y(2.0) = 1.000073982338, y(3.0) = 1.000006249016 (settled on r before the step); after the step y(3.05) = 1.001168788483, y(3.25) = 1.008944174201 (peak excursion), y(4.0) = 1.001300603879, y(6.0) = 0.999999797512.
- Worked metrics: e(6.0) = -2.025e-07; max |e| over [3.0, 6.0] = 9.161e-03 (the disturbance-step excursion); max |e| over [5.5, 6.0] = 8.016e-07 and max |z3 - f_truth| over [5.5, 6.0] = 1.403e-06 (the settled band); u(6.0) = -1.000001803850 against the exact -1.0; z3(6.0) = 0.999999402193 against f_truth(6.0) = 0.999999537946.
- Ideal closed form: the double integrator step response y(t) = 1 - (1 + omega_c t) exp(-omega_c t) gives 0.264241117657 at t = 0.2 s and 0.959572318005 at t = 1.0 s; the ideal Euler run reproduces the t = 1.0 s value to 3.369e-05 (Euler truncation at dt = 1e-4).
- Ideal-loop comparison: max |y_adrc - y_ideal| over [0.0, 6.0] = 9.172e-03, over [5.5, 6.0] = 8.015e-07; observer-lag deficit y_adrc(1.0) - y_ideal(1.0) = 0.003958874713 (the observer trails the perfect-cancellation loop during the fast reference transient).
- Mismatch robustness run (b = 0.8, b0 = 1.0): y(6.0) = 1.000000346701 (still settles at r); u(6.0) = -1.249993763548, z3(6.0) = 1.249999451753; the estimate carries the fixed bias z3 - f = (b - b0) u = 0.25, real max |z3 - f| over [5.5, 6.0] = 2.500e-01.
- ValueErrors (real messages): observer_gains(0.0) raises "observer bandwidth omega_o must be positive, got 0.0"; controller_gains(0.0) raises "controller bandwidth omega_c must be positive, got 0.0"; control_law and cancellation_residual with b0 = 0.0 raise "control-effectiveness estimate b0 must be nonzero, got 0.0"; simulate_adrc(omega_c=5.0, omega_o=5.0) raises "observer bandwidth omega_o must exceed the controller bandwidth omega_c, got omega_o 5.0 <= omega_c 5.0"; simulate_adrc(t_step=6.0) raises "disturbance step time t_step must lie strictly inside (0, sim_time), got t_step 6.0 for sim_time 6.0".
Verification
- Confirm observer_gains(30.0) equals (90.0, 2700.0, 27000.0) and controller_gains(5.0) equals (25.0, 10.0) within 1e-9, and that char_poly_residual is below 1e-9 at s = -30, -3, -1 and 0.5.
- Confirm cancellation_residual(f, u0, f, b0) is below 1e-12 for any f, u0, b0, the algebraic witness that z3 = f collapses the plant channel to the double integrator y_ddot = u0.
- Confirm the worked-run sample points at 0.2, 0.5, 1.0, 2.0, 3.0, 3.05, 3.25, 3.5, 4.0, 5.0 and 6.0 s match the quoted anchor values within 1e-6 relative, and that the settled-window residuals max_abs_e_settle and max_z3_res_settle stay below 1e-5 and 1e-4.
- Confirm the ideal-loop comparison bounds max |y_adrc - y_ideal| and the observer-lag deficit at t = 1.0 s against the quoted anchor.
- Confirm the mismatch robustness run still settles at the reference while the estimate bias matches (b - b0) u to within 1e-3.
- Confirm ValueError rejection of a non-positive omega_o or omega_c, a zero b0, omega_o not exceeding omega_c, a non-positive dt or sim_time, and a t_step outside (0, sim_time), with the real messages quoted in the Worked example.
- Run the contract test offline: python3 scripts/test_active_disturbance_rejection_control.py (deterministic, no imports beyond math, no exact-float equality on any computed sum).
Related leaves
- gnc-autonomy/control/observer-design: designs a full-order Luenberger state observer for a known LTI plant by Ackermann pole placement at arbitrary locations; this leaf's three observer gains come only from the (s + omega_o)^3 expansion, augment the disturbance state, and exist only inside the disturbance-rejection control law.
- gnc-autonomy/control/adaptive-control: updates two gains online against an unknown plant coefficient with a gradient adaptation law; this leaf's gains are fixed closed forms of two bandwidths and nothing adapts, and the disturbance is the object the observer estimates and the law cancels.
- gnc-autonomy/control/l1-adaptive-control: runs a state predictor and a projection-based adaptation law through a low-pass filter; this leaf runs no predictor, no projection and no adaptive signal, and its observer is a fixed linear estimator, not a filtered adaptive estimate.
- gnc-autonomy/control/pid-control-design: tunes P-I-D gains by Ziegler-Nichols or pole placement with anti-windup and margin checks; this leaf never tunes, its kp, kd and beta gains are given closed forms of omega_c and omega_o, and the disturbance is rejected through the estimated z3 rather than integrated away.
- gnc-autonomy/control/sliding-mode-control: reconstructs no disturbance and instead bounds a constant matched disturbance with a switching term sized above the bound; this leaf reconstructs the total disturbance with a fixed-gain linear observer and cancels it, with no switching term.
Pitfalls
- Treating this leaf as an adaptive or predictor-based law: the observer gains and the outer-loop gains are always fixed closed forms of omega_o and omega_c, nothing updates online, and there is no state predictor, projection or low-pass adaptive filter (adaptive-control, l1-adaptive-control territory).
- Designing the observer for a known plant model: the LESO never needs the plant model, because the augmented third state z3 absorbs the internal dynamics into the total disturbance; feeding a known model through an Ackermann pole-placement design belongs to observer-design, not here.
- Choosing omega_o too close to omega_c: the spec's practical band is 4 to 10 times the controller bandwidth (the worked ratio is 6); a narrower ratio slows the disturbance estimate and widens the step-response excursion after a disturbance change.
- Ignoring the b0-mismatch bias: when the true gain b differs from the design estimate b0, the output still settles at the reference but the total-disturbance estimate carries a fixed bias (b - b0) u forever, not a transient that decays away.
- Reading the observer-lag deficit as a design defect: the finite- bandwidth LESO always trails the ideal perfect-cancellation loop during fast transients (the worked deficit is 0.003958874713 at t = 1.0 s), and this cost only vanishes once both loops reach the same fixed point.
- Reproducing ARP4754A text verbatim: the standard is reference-only, summary-only per standards-map.yaml.
Behavior contract (gate 3)
Run the deterministic contract test (stdlib unittest, offline):
python3 scripts/test_active_disturbance_rejection_control.py
The test covers the bandwidth-parameterization closed forms and the LESO characteristic-polynomial identity, the disturbance-cancellation residual identity, the exact ideal double-integrator closed form reproduced by the Euler run, the worked-run sample points and settled- window residuals, the ideal-loop comparison and observer-lag deficit, the mismatch robustness run and its fixed estimate bias, ValueError rejection of every non-physical input, and determinism across repeated runs (40 test methods).