Adaptive Backstepping (gnc-autonomy/control/adaptive-backstepping)
Use when the task is a recursive strict-feedback design for a second-order nonlinear plant whose channel-1 drift carries an unknown constant parameter theta: build the control law one error variable at a time, the same recursion shape as backstepping-control, but replace the known-drift term with the online estimate theta_hat and drive that single estimate with the second tuning function carried through the recursion. The channel-2 drift f2 and the design gains c1, c2 and adaptation rate gamma are given inputs, never identified or tuned; only theta is unknown, and it is estimated by ONE parameter update, never over-parameterized. It pairs with backstepping- control, the exact-model recursion this leaf reduces to at zero adaptation gain, and never overlaps adaptive-control, whose first-order plant and model-reference tracking error drive two adaptive gains, or l1-adaptive- control, whose state predictor and low-pass-filtered adaptation law estimate a lumped uncertainty rather than a structural drift coefficient.
Domain quick reference
- Plant: second-order strict feedback x1_dot = x2 + theta f1(x1), x2_dot = u
- f2(x1, x2), unit control gain, f1(x1) = x1^2 (known shape, unknown constant theta multiplying it), f2(x1, x2) = x1 x2 (known exactly), x1 and x2 measured, theta not measured.
- Reference x1d(t): constant kind gives x1d = REF_SETPOINT with zero derivatives; sinusoidal kind gives x1d = SIN_AMP sin(SIN_OMEGA t) with the matching first and second derivatives.
- First error variable z1 = x1 - x1d; virtual control alpha1 = -c1 z1 + x1d_dot - theta_hat w1 with w1 = f1(x1), so z1_dot = -c1 z1 + z2 + theta_tilde w1 with theta_tilde = theta - theta_hat.
- Second error variable (mismatch) z2 = x2 - alpha1.
- Design-model derivative (theta_hat as the plant coefficient, since theta is unknown to the controller): alpha1_dot = -(c1 + theta_hat df1(x1)) (x2 + theta_hat w1) + c1 x1d_dot + x1d_ddot - theta_hat_dot w1, with df1(x1) = 2 x1.
- Tuning functions: tau1 = gamma z1 w1 (first step), w2 = (c1 + theta_hat df1(x1)) w1, tau2 = gamma (z1 w1 + z2 w2) (second, the estimator update theta_hat_dot = tau2), the positive w2 convention that cancels the parameter-mismatch terms out of the z2 dynamics.
- Final control u = -f2(x1, x2) + alpha1_dot - z1 - c2 z2; substituting gives z2_dot = -z1 - c2 z2 + theta_tilde w2.
- Augmented Lyapunov function V2 = (z1^2 + z2^2)/2 + theta_tilde^2/(2 gamma); with theta_hat_dot = tau2 the parameter-mismatch terms cancel and V2_dot = -c1 z1^2 - c2 z2^2 exactly in continuous time.
- Reduction identity: at gamma = 0 with theta_hat(0) = theta, theta_hat stays frozen and the construction reduces exactly to the backstepping- control exact-model recursion.
Workflow
- Fix the plant and the design inputs: the known drift shape f1(x1) = x1^2 and the known channel-2 drift f2(x1, x2) = x1 x2, the reference kind (constant or sinusoidal), the design gains c1, c2, the adaptation rate gamma and the initial state and parameter estimate. Only theta is unknown; c1, c2 and gamma are given, never tuned online.
- Form the first error variable z1 = x1 - x1d with tracking_error, and the theta_hat-carrying virtual control with alpha1_value(z1, ref_dot, theta_hat, w1, c1): alpha1 = -c1 z1 + x1d_dot - theta_hat w1, where w1 = w1_regressor(x1).
- Propagate the inner-state mismatch as the second error variable with mismatch_error(x2, alpha1): z2 = x2 - alpha1.
- Form the design-model derivative of the virtual control with alpha1_dot_adaptive(x1, x2, ref_dot, ref_ddot, theta_hat, th_dot, c1), evaluated with theta_hat as the plant coefficient because theta is unknown to the controller.
- Build the tuning functions with tau1_value(z1, w1, gamma) and tau2_value(z1, z2, w1, w2, gamma), using w2 = omega2_regressor(x1, theta_hat, c1); the single parameter estimate updates as theta_hat_dot = tau2, the second tuning function carried through the recursion.
- Assemble the recursive final control with final_control(f2_value, alpha1_dot, z1, z2, c2): u = -f2 + alpha1_dot - z1 - c2 z2, then simulate the closed loop with simulate(c1, c2, gamma, kind).
- Audit the z1-map and z2-map residual identities, the augmented-Lyapunov decay realized by v2_value against the design rates c1, c2, and the convergence of theta_hat toward theta and of z1, z2 toward zero.
Worked example
Plant x1_dot = x2 + theta x1^2, x2_dot = u + x1 x2, theta = 1.0 the unknown constant (the controller sees only theta_hat), unit control gain. Design gains c1 = c2 = 2.0 (1/s), gamma = 5.0 (worked case A), c1 = c2 = 4.0, gamma = 10.0 (rate case B), gamma = 0.0 with theta_hat(0) = theta (reduction case C), gamma = 20.0 with a sinusoidal reference (persistent-excitation case D). Initial state x1(0) = 0, x2(0) = 0, theta_hat(0) = 0 (cases A, B, D) or 1.0 (case C). Forward Euler at dt = 0.001 s. All values below are real outputs of scripts/adaptive_backstepping_logic.py:
- Worked case A (constant reference, c1 = c2 = 2.0, gamma = 5.0, horizon 10 s): initial z1(0) = -1.0000000000, z2(0) = -2.0000000000, alpha1(0) = 2.0000000000, u(0) = 5.0000000000, theta_tilde(0) = 1.0000000000, V2(0) = 2.6000000000. Audit residuals z1_map_max = 1.569160e-03, z2_map_max = 1.101886e-02, v2_mono_viol = 0 (V2 monotone non-increasing over all 10000 steps). Parameter transient: theta_hat dips to -0.4386805331 at t = 1.0 s before recovering to theta_hat(10) = 1.0000982189 (theta_tilde = -0.0000982189). Final sample T = 10.0 s: x1 = 0.9999809509, x2 = -1.0001096335, z1 = -0.0000190491, z2 = -0.0000876144, u = 1.0023303954, V2 = 0.0000000050. Sample points: x1(0.5) = 0.3390297388, x1(1.0) = 0.9731049081, x1(2.0) = 1.0363587713, x1(4.0) = 0.9961053848, x1(6.0) = 0.9988545516; theta_hat(2.0) = 0.9031981710, theta_hat(6.0) = 0.9967713046.
- Rate case B (c1 = c2 = 4.0, gamma = 10.0, horizon 6 s): z2(0) = -4.0000000000, u(0) = 17.0000000000, V2(0) = 8.5500000000. Final T = 6.0 s: theta_hat = 1.0000484342, x1 = 1.0000045989, z1 = 0.0000045989, z2 = 0.0000212992, u = 0.9986281208, tighter than the worked case at the same horizon, the c1, c2, gamma rate lever.
- Reduction case C (gamma = 0.0, theta_hat(0) = 1.0, horizon 6 s): the exact-model limit of backstepping-control. z1(0) = -1.0000000000, z2(0) = -2.0000000000, u(0) = 5.0000000000; theta_hat frozen exactly (max deviation 0.0); z1_map_max = 1.110223e-16 (machine exact, the sibling's own witness); final x1 = 0.9999973792, u = 1.0000620640, matching the sibling's worked-case final values (x1 = 0.999997441, u = 1.000062552) within the discretization band; sample cross-check x1(0.5) = 0.3244768479 vs sibling 0.324501865, x1(4.0) = 1.0007242372 vs 1.000722845.
- PE case D (sinusoidal reference, gamma = 20.0, horizon 40 s): the persistently exciting reference drives theta_hat to theta: theta_hat(40) = 0.9996543840 (|theta_tilde| = 3.456160e-04), max |z1| over the run = 0.2049438438, z1(40) = 0.0000904604, v2_mono_viol = 0.
- Closed-form identities: alpha1_value(-1.0, 0.0, 0.0, 0.0, 2.0) = 2.0000000000; omega2_regressor(1.0, 1.0, 2.0) = 4.0000000000; V2(0) = v2_value(-1.0, -2.0, 1.0, 5.0) = 2.6000000000.
- ValueErrors (real messages): alpha1_value(0.1, 0.0, 0.0, 0.1, 0.0) raises "design gain c1 must be positive, got 0.0"; alpha1_dot_adaptive (0.1, 0.0, 0.0, 0.0, 0.1, 0.0, 0.0) raises "design gain c1 must be positive, got 0.0"; final_control(0.1, 0.0, 0.1, 0.1, 0.0) raises "design gain c2 must be positive, got 0.0"; simulate(c1=0.0) raises "design gain c1 must be positive, got 0.0"; simulate(c2=0.0) raises "design gain c2 must be positive, got 0.0"; simulate(gamma=-1.0) raises "adaptation gain gamma must be non-negative, got -1.0"; simulate(dt=0.0) raises "sample time dt must be positive, got 0.0"; simulate(sim_time= 0.0) raises "simulation time sim_time must be positive, got 0.0"; reference(0.5, 'ramp') raises "reference kind must be 'constant' or 'sinusoidal', got 'ramp'"; v2_value(-1.0, -2.0, 1.0, 0.0) raises "adaptation gain gamma must be positive, got 0.0".
Verification
- Confirm the recursion algebra closed forms: alpha1_value(-1.0, 0.0, 0.0, 0.0, 2.0) = 2.0, mismatch_error(0.0, 2.0) = -2.0, v2_value(-1.0, -2.0, 1.0, 5.0) = 2.6, omega2_regressor(1.0, 1.0, 2.0) = 4.0.
- Confirm the worked, rate, reduction and persistent-excitation cases converge theta_hat toward theta and z1, z2 toward zero within the bounds quoted in the Worked example.
- Confirm the augmented Lyapunov function V2 is monotone non-increasing (v2_mono_viol = 0) in every case, absorbing the non-PE parameter- transient dip without a stability violation.
- Confirm the zero-adaptation-gain reduction case matches the backstepping-control sibling worked case within the discretization band, and that theta_hat stays exactly frozen when gamma = 0.
- Confirm ValueError rejection of non-positive c1, non-positive c2, a negative gamma, a non-positive dt or sim_time, and an unrecognized reference kind, with the real messages quoted in the Worked example.
- Run the contract test offline: python3 scripts/test_adaptive_backstepping.py (deterministic, no imports beyond math, no exact-float equality on any computed sum).
Related leaves
- gnc-autonomy/control/backstepping-control: the exact-model recursion for the same second-order strict-feedback plant with both drift terms known exactly and no estimator; this leaf reduces to it exactly at zero adaptation gain with theta_hat(0) = theta.
- gnc-autonomy/control/adaptive-control: a model-reference adaptive controller for a first-order plant with two adaptive gains updated by a gradient law on a reference-model tracking error; this leaf's plant is second-order strict feedback, carries one estimator, and its update is the tuning-function combination z1 w1 + z2 w2, not a model-reference error.
- gnc-autonomy/control/l1-adaptive-control: runs a state predictor and a projection-based adaptation law through a low-pass filter for a first-order plant with a lumped-uncertainty estimate; this leaf runs no predictor, no projection and no filter, and its estimator targets a single structural drift coefficient.
- gnc-autonomy/control/sliding-mode-control: switches on an error surface with an equivalent control plus a boundary-layer term; this leaf has no surface, no switching term, and its control is continuous.
- gnc-autonomy/control/feedback-linearization: cancels the plant nonlinearities by Lie-derivative decoupling; this leaf never inverts the plant, its linear closed-loop behavior appears only in the error coordinates.
- gnc-autonomy/control/observer-design: designs a Luenberger state observer; this leaf assumes x1 and x2 are measured and estimates only the scalar parameter theta, never the states.
Pitfalls
- Reading this leaf as the exact-model recursion: f2, c1, c2 and gamma are given inputs, but theta is genuinely unknown and estimated online (that distinction is what separates this leaf from backstepping-control).
- Confusing the tuning-function update with a model-reference gradient law: theta_hat_dot = tau2 = gamma (z1 w1 + z2 w2) is carried through the second-order recursion, not a gradient on a reference-model tracking error (adaptive-control territory).
- Getting the w2 sign wrong: omega2_regressor must use the POSITIVE convention (c1 + theta_hat df1(x1)) w1; the negative-sign variant makes the closed loop diverge to NaN inside 2 s, which the contract test's audit bounds catch immediately.
- Differentiating alpha1 with the TRUE parameter theta instead of theta_hat: the design-model derivative alpha1_dot_adaptive must use theta_hat as the plant coefficient in x1_rate, since theta is unknown to the controller; using theta breaks the tuning-function cancellation.
- Adding a second adaptive gain or over-parameterizing the estimator: the construction carries exactly ONE parameter estimate theta_hat, never a vector of estimates.
Behavior contract (gate 3)
The reference, error-variable, adaptive virtual-control, mismatch, design-model derivative, tuning-function, final-control and closed-loop simulation logic is exercised by the gate 3 contract test: scripts/test_adaptive_backstepping.py against scripts/adaptive_backstepping_logic.py (stdlib unittest, offline, deterministic, 44 test methods). Run:
python3 scripts/test_adaptive_backstepping.py
Compliance
- ARP4754A is proprietary (SAE); name and paraphrase only, per standards-map.yaml, as the reference-only control-pack convention shared with backstepping-control, adaptive-control, l1-adaptive-control, pid-control-design, observer-design and sliding-mode-control.
- Revision note: ARP4754B (2023) supersedes ARP4754A; this skill keys to ARP4754A as the certification-baseline revision (FAA AC 20-174 cites A); see standards-map.yaml arp4754a.revision_decision.
- compliance: STANDARDS-REF, gated: false.