ECSS Structures — CAD Model and Drawing Description (space-systems/ecss/drd-cad-model-description)
Use when the task is to validate a CAD Model and Drawing Description Document (CADMDD) for structural design delivery per ECSS-E-ST-32C Annex A — checking that every mandatory content element is present, correctly formed, and consistent before the document is released into configuration control.
Domain quick reference
- Annex A of ECSS-E-ST-32C defines the required content of the CADMDD: the model format declaration, coordinate system definition, assembly tree, drawing title block, mass properties record, and interface definitions. Each element must be present and internally consistent for the delivery to be accepted.
- Accepted model formats are either neutral exchange formats (STEP AP214, STEP AP242, IGES) or identified native CAD formats (CATIA V5, CATIA V6, Siemens NX, Creo, SolidWorks). A format not on this list is not a recognised delivery medium and must be rejected before further checks proceed.
- The coordinate system definition must state the origin, the positive X and Y axis directions, and the handedness (right-handed is the structural standard). An axis definition without handedness is ambiguous and cannot be accepted.
- The assembly tree lists every component by ID and description. A component entry without an ID, or with an ID that duplicates another entry in the same delivery, is a structural integrity finding.
- The drawing title block must carry at minimum: document number, title, revision identifier, release date, originator, and approval authority. A missing approval authority means the drawing has not been formally authorised.
- Mass properties (mass, centre of gravity in X/Y/Z, diagonal inertia tensor terms Ixx/Iyy/Izz) must all be present and non-negative. A negative mass or a missing inertia term is an invalid record.
- Interface definitions must each carry an interface ID, an interface type (mechanical, thermal, electrical, optical, or fluid), and the mating component identifier. An interface entry missing any of these three fields is incomplete.
- Model maturity must be declared as one of four recognised levels: preliminary, development, released, or superseded. An undeclared or unrecognised maturity code means the configuration status cannot be determined.
Workflow
- Confirm the model format string matches an accepted exchange or native format; reject and stop if it does not.
- Check the coordinate system record for the required fields (origin, x_axis, y_axis, handedness) and for a valid handedness value; collect any missing or invalid fields as findings.
- Walk the model tree component list; flag any component without an id field and any component whose id duplicates an earlier entry.
- Validate the drawing title block against the required field set; flag every missing field.
- Check the mass properties record: verify all seven numeric fields are present and that mass_kg, ixx_kg_m2, iyy_kg_m2, and izz_kg_m2 are non-negative (the centre-of-gravity coordinates may be negative); flag each missing field or invalid value.
- Validate the maturity level against the four recognised codes; flag an unrecognised or absent value.
- For each interface definition, verify that interface_id, interface_type, and mating_component are all present and that interface_type is one of the five valid types; flag each incomplete or invalid entry.
- Aggregate all findings by category; the CADMDD delivery is compliant only when every category list is empty.
Pitfalls
- Accepting a proprietary format not on the recognised list because it opens correctly on the current workstation — format acceptability is a delivery contract requirement, not a tool capability check.
- Treating a coordinate system entry as valid when handedness is absent — a right-hand/left-hand ambiguity propagates silently into every subsequent load-path and interface geometry calculation.
- Skipping the assembly tree duplicate-ID check when the tree is generated automatically by the CAD tool — tools can and do produce duplicate IDs on copy-paste or library reuse, and a duplicate is a configuration control failure.
- Reading a missing approval authority as a formatting gap rather than a compliance finding — an unapproved drawing must not enter configuration control regardless of its technical content.
- Accepting a mass properties record where the inertia diagonal is omitted because only mass and CoG were requested by the customer — Annex A requires the full tensor diagonal; partial records are incomplete.
Behavior contract (gate 3)
The format validation, coordinate system check, model tree check, title block check, mass property check, maturity level check, interface definition check, and aggregate compliance logic are exercised by the gate 3 contract test: scripts/test_drd_cad_model_description.py against scripts/drd_cad_model_description_logic.py (stdlib unittest, offline). Run: python3 scripts/test_drd_cad_model_description.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.