ECSS Software Tool Qualification for Verification by Analysis (space-systems/ecss/e1002-sw-tools)
Use when the task is qualifying a software tool used to produce verification-by-analysis evidence under ECSS-E-ST-10-02C, before that tool's output is accepted into the verification close-out record.
Domain quick reference
- ECSS-E-ST-10-02C clause 5.2.6.5 requires that software tools used for verification by analysis be qualified for that use, consistent with the general tool/model validation principle of ECSS-E-ST-10C clause 5.3.4 (analysis methods, tools and models are validated before use, within a stated domain of applicability).
- Qualification rests on four checks: the tool has been validated (against reference cases, benchmarks, or correlated test data); the specific tool version is under configuration control for the analysis campaign (an unfrozen tool can drift mid-campaign); the actual analysis conditions fall inside the tool's validated domain (parameter ranges, physics assumptions the validation covered); and, for a safety-critical or high-consequence use, an independent cross-check exists (alternate tool, hand calculation, or code-to-code comparison).
- A tool that fails any earlier check is not qualified for that use regardless of how the later checks would have come out -- the checks are a precedence chain, not independent votes.
- This leaf qualifies the tool for one analysis use; classifying the tool into a qualification category (A/B/C/D) is the sibling e1002-tools-general leaf, and validating analysis methods/tools/ models in general (not software-specific) is the sibling e10-analysis-tools-models leaf.
Workflow
- For each software tool use supporting a verification-by-analysis case, capture: whether the tool itself has been validated, whether the version in use is under configuration control, the tool's validated domain (per-parameter ranges it was validated over), and the actual analysis conditions (per-parameter values used in this run).
- Check the analysis conditions against the validated domain: any parameter used in the analysis that is missing from the validated domain or falls outside its range is out-of-domain for this use.
- Determine qualification status by precedence: not validated -> not qualified; validated but not configuration-controlled -> qualified pending configuration control; validated and controlled but out-of-domain -> qualified out of domain; validated, controlled, in-domain, safety-critical without an independent check -> qualified pending independent check; otherwise -> qualified.
- Build the qualification record for the full set of tool uses feeding an analysis report or the Design Justification File, and identify every use whose status is anything other than qualified.
- Route every non-qualified use back to disposition (re-validate the tool, freeze its configuration, re-run inside the validated domain, or add an independent check) before its output is accepted as verification-by-analysis evidence in the VCD close-out.
Pitfalls
- Accepting analysis output from a tool that is validated in general but was run outside the domain (parameter range, assumptions) the validation actually covered.
- Treating "validated" and "configuration controlled" as the same check -- a validated tool whose version drifts mid-campaign is no longer known-good for the campaign's results.
- Skipping the independent-check requirement for a safety-critical analysis because the tool itself is otherwise qualified.
- Letting one non-qualified tool use quietly ride along inside an otherwise-qualified analysis report instead of flagging it for disposition.
Behavior contract (gate 3)
The domain-check, qualification-precedence, record-building, and acceptance logic is exercised by the gate 3 contract test: scripts/test_e1002_sw_tools.py against scripts/e1002_sw_tools_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1002_sw_tools.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.