ECSS Verification Tool Classification & Qualification Status (space-systems/ecss/e1002-tools-general)
Use when the task is classifying a tool used to support or generate verification evidence under ECSS-E-ST-10-02C, and assigning it a qualification-status category before its results are accepted into the verification programme. The detailed qualification rules for specific tool families (GSE, simulators, software tools, facilities) live in the sibling leaves e1002-gse-tools, e1002-simulators, e1002-sw-tools, and e1002-facilities; this leaf owns the general classification and category-assignment step that precedes them.
Domain quick reference
- ECSS-E-ST-10-02C clause 5.2.6.1 requires every tool used in verification (test equipment, ground support equipment, simulators, software tools, facilities) to be identified, categorized by type, and given a qualification status before its output is accepted as verification evidence.
- A tool that only supports the activity (handling, access, non-recorded observation) without generating the accepted evidence does not need a qualification category beyond basic serviceability.
- A tool whose output does generate the accepted evidence is qualified to one of four status categories (A most stringent through D least stringent), driven by two factors: the criticality of the requirement the tool's evidence supports (safety-critical, mission-critical, standard, or negligible), and whether an independent corroborating source exists for the same evidence.
- Category assignment must never be manually weakened below what the requirement criticality and corroboration state require; a proposed downgrade on a safety- or mission-critical tool is a disposition item, not a silent acceptance.
Workflow
- For each tool used anywhere in the verification programme, capture: a tool type (test equipment, GSE, simulator, software tool, facility, or other), whether its output generates the accepted verification evidence (as opposed to merely supporting the activity), the criticality of the requirement(s) it supports (safety-critical, mission-critical, standard, negligible), and whether an independent corroborating source exists for the same evidence.
- Assign the qualification-status category by precedence: a tool that does not generate accepted evidence -> category D; else safety-critical requirement with no corroboration -> category A; safety-critical with corroboration, or mission-critical with no corroboration -> category B; mission-critical with corroboration, or standard criticality -> category C; negligible criticality -> D.
- Attach the qualification actions expected for the assigned category: A requires full qualification with configuration control and traceable calibration before use; B requires documented qualification against defined performance requirements plus calibration traceability; C requires calibration or checkout against the manufacturer specification recorded in the tool's usage record; D requires only a basic serviceability check.
- Build the tool register: one (type, category, actions) entry per tool id, and confirm every tool id used in the verification programme appears in the register -- an incomplete register leaves verification evidence resting on an uncategorized tool.
- Before accepting a manually assigned category, re-check it against the category the criticality/corroboration rule would compute and flag any case where the manual category is weaker (less stringent) than required, for engineering disposition rather than silent acceptance.
- Hand tools flagged as GSE, simulator, software tool, or facility to the matching sibling leaf (e1002-gse-tools, e1002-simulators, e1002-sw-tools, e1002-facilities) for the family-specific qualification detail; record the general category here regardless.
Pitfalls
- Treating a support-only tool (handling, access) as if it generates verification evidence and over-qualifying it, or the reverse: treating an evidence-generating tool as support-only to avoid qualification.
- Assigning category C or D to a tool whose evidence is the sole support for a safety-critical requirement, understating the rigor clause 5.2.6.1 calls for.
- Leaving a tool out of the register because it is informally used (a bench meter, a one-off script) even though its output is accepted as verification evidence.
- Accepting a manually requested category downgrade on a safety- or mission-critical tool without an engineering disposition.
Behavior contract (gate 3)
The classification, category-assignment, register-completeness, and downgrade-guard logic is exercised by the gate 3 contract test: scripts/test_e1002_tools_general.py against scripts/e1002_tools_general_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1002_tools_general.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.