ECSS Equipment Electrical/RF Tests (space-systems/ecss/e1003-eq-electrical)
Use when the task is scoping and running the equipment-level electrical and RF test set of ECSS-E-ST-10-03C for one piece of equipment, ahead of mission-specific tests (sibling e1003-eq-mission leaf) and equipment-level test baseline closure (sibling e1003-eq-qual / e1003-eq-acceptance / e1003-eq-protoflight leaves).
Domain quick reference
- ECSS-E-ST-10-03C clause 5.5.5 groups six electrical/RF test types for equipment: electromagnetic compatibility (EMC), magnetic, electrostatic discharge (ESD), passive intermodulation (PIM), multipactor, and corona/arc discharge.
- Not every test in the set applies to every equipment item. Each test's applicability is driven by an equipment-level risk or requirement flag established during design and analysis, not by running the test itself: EMC applies to any equipment with electrical interfaces; magnetic applies only when the project has levied a magnetic-cleanliness requirement; ESD applies when an external dielectric surface is exposed to a charging environment; PIM and multipactor apply only to RF equipment already flagged with the corresponding risk (multi-carrier RF chain for PIM, high RF power in vacuum for multipactor); corona/arc-discharge applies when high voltage is present together with an assessed risk of operating in the pressure transition region.
- Equipment with no electrical interfaces at all is out of scope for the entire 5.5.5 set -- every test is not applicable, and this leaf should not be invoked for it.
- A test that is applicable but has no recorded result is "missing", distinct from "not applicable" (out of scope) and from "failed" (run and did not pass); a campaign cannot close while any applicable test is missing.
Workflow
- For each equipment item, capture its electrical/RF risk flags: has_electrical_interfaces, magnetic_cleanliness_required, esd_susceptible, pim_risk_present, multipactor_risk_present, corona_arc_risk_present.
- Determine applicability of each of the six tests from those flags. Equipment without electrical interfaces is not applicable for the whole set; otherwise EMC is always applicable and the remaining five follow their individual flag.
- For each applicable test, record its result (passed or failed) as it becomes available; leave it unset until then.
- Disposition each test's status: not_applicable (out of scope), missing (applicable, no result yet), passed, or failed.
- Roll up the equipment's overall electrical/RF test status: failed if any test failed, incomplete if none failed but at least one applicable test is still missing, complete only when every applicable test has passed.
- Build the campaign disposition across every equipment item in scope and confirm no equipment id from the intended set is missing before closing out the electrical/RF test set for that item.
Pitfalls
- Treating a test with no recorded result as "not applicable" instead of "missing" -- silently drops a required test from the campaign.
- Running the magnetic or ESD test on equipment that never had the corresponding requirement flagged, or skipping PIM/multipactor on RF equipment that was flagged with the risk but treated as generic hardware.
- Declaring the campaign complete when one applicable test failed but the others passed -- one failure fails the whole equipment item, it does not average out.
- Invoking the full 5.5.5 set on equipment that has no electrical interfaces at all, instead of recognizing the set is out of scope.
Behavior contract (gate 3)
The applicability, per-test status, and campaign roll-up logic is exercised by the gate 3 contract test: scripts/test_e1003_eq_electrical.py against scripts/e1003_eq_electrical_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1003_eq_electrical.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.