ECSS Equipment Qualification Test Baseline (space-systems/ecss/e1003-eq-qual)
Use when the task is defining the equipment qualification test baseline of an ECSS-E-ST-10-03C testing programme: which test families apply and in what order (clause 5.2 + Table 5-1), and the qualification level and duration each applicable test must demonstrate (Table 5-2), ahead of running the per-test-family rules owned by the sibling 5.5.x leaves.
Domain quick reference
- ECSS-E-ST-10-03C clause 5.2 sets the qualification test baseline for equipment: a fixed catalogue of test families (physical properties, functional/performance, mechanical, pressure integrity, thermal, electrical/RF, mission-specific) run in a defined sequence, with functional/performance checks bracketing the environmental exposures so any induced degradation is caught before and after stress.
- Table 5-1 tailors which test families actually apply to a given piece of equipment: physical-properties, functional/performance, and thermal are baseline for essentially all equipment, while mechanical, pressure-integrity, electrical/RF, and mission-specific tests are enabled by the equipment's own characteristics (it carries mechanical loads, is pressurized, contains electronics, or has a mission-unique test need).
- Table 5-2 derives each applicable test's qualification level and duration from its reference (predicted/design) level and duration by applying a margin and a duration factor -- qualification demonstrates margin beyond the flight-reference environment, not just reproduction of it. A margin can be applied multiplicatively (e.g. a levels ratio) or additively (e.g. a temperature offset); the duration factor is always multiplicative.
- The per-test-family numeric rules (actual levels, durations, tolerances, success criteria for mechanical/pressure/thermal/ electrical/mission-specific tests) are owned by the sibling 5.5.x leaves (e1003-eq-mechanical, e1003-eq-pressure, e1003-eq-thermal, e1003-eq-electrical, e1003-eq-mission); this leaf only fixes the baseline sequence and the level/duration derivation rule that those per-family inputs plug into.
Workflow
- Capture the equipment's test-applicability attributes: does it carry mechanical (launch) loads, is it pressurized, does it contain electronics, does it have a mission-specific test need.
- Select the applicable test families from those attributes (physical-properties, functional/performance, and thermal are always in scope; the rest are enabled per attribute).
- Build the baseline sequence: physical-properties and an initial functional/performance check first, then the applicable environmental families in their fixed clause order (mechanical, pressure-integrity, thermal, electrical), then a closing functional/performance retest, then any mission-specific test last.
- For every environmental family in the sequence, gather its Table 5-2 inputs: reference level, reference duration, margin, duration factor, and margin mode (multiplicative or additive).
- Derive the qualification level and duration for each of those families from its inputs, and attach the result to its sequence step.
- Before handing the baseline to test-programme execution, confirm every environmental family in the sequence has a qualification level/duration attached; list any family still missing one rather than assuming the baseline is ready.
Pitfalls
- Dropping the initial or final functional/performance check from the sequence -- without both, degradation caused by the environmental tests in between cannot be attributed to a specific test.
- Reusing the flight-reference (acceptance-level) environment as the qualification level/duration directly, instead of applying the margin and duration factor -- qualification without margin does not demonstrate the robustness the stage exists to prove.
- Applying a multiplicative margin where the input is actually an additive offset (e.g. treating a temperature margin as a ratio) -- the margin mode must match how the family's environment is expressed.
- Treating the baseline as ready for execution while an applicable environmental family still has no qualification level/duration attached.
Behavior contract (gate 3)
The applicability-selection, sequence-building, and level/duration derivation logic is exercised by the gate 3 contract test: scripts/test_e1003_eq_qual.py against scripts/e1003_eq_qual_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1003_eq_qual.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.