ECSS FLUMIC Worst-Case Trapped Electron Model (space-systems/ecss/e1004-b4-flumic)
Use when the task is implementing the FLUMIC worst-case trapped
electron model under ECSS-E-ST-10-04C Annex B.4, to bound the electron
energy spectrum in the outer radiation belt (including geostationary
altitudes) and the inner belt for internal (deep-dielectric) charging
design.
Domain quick reference
- FLUMIC characterizes the trapped electron environment as a
worst-case energy spectrum rather than a long-term average: it
answers "how bad can the electron flux get" for a stated confidence
level and exposure duration, which is the input internal-charging
analyses need, not the mission-average flux the long-term belt
models (sibling e1004-trapped-leo, e1004-geo-ige, e1004-meo-meov2
leaves) provide.
- The model spans two distinct belt regions with different reference
spectra: the outer belt (harder spectrum, extending to higher
electron energies, dominant driver of GEO and outer-belt internal
charging risk) and the inner belt (softer spectrum). An orbit that
crosses both regions needs the combined contribution of both.
- "Worst case" is only meaningful relative to a confidence (percentile)
level and an exposure-duration class: a short duration class
(a single worst day) bounds transient peak flux for peak-risk
assessments, while a long duration class (the mission life) gives
the appropriate cumulative-fluence bound -- these are not
interchangeable, and picking the wrong one for the analysis purpose
gives a spectrum that does not answer the question being asked.
- Internal (deep-dielectric) charging risk depends on the flux of
electrons energetic enough to penetrate typical shielding and
deposit charge in dielectric materials, so the assessment needs the
integral flux above a shielding-relevant threshold energy, not the
full differential spectrum.
- This leaf scopes the FLUMIC spectral evaluation and threshold
integration only. Rolling FLUMIC together with the NASA worst-case
GEO electron spectrum into an internal-charging assessment is the
sibling e1004-internal-charging leaf (clause 9.2.1.3); the NASA
worst-case GEO spectrum itself is the sibling e1004-b5-geo-wc leaf
(Annex B.5).
Workflow
- For each internal-charging case, record its belt region(s)
(inner belt, outer belt, or both, from the orbit's belt crossings),
its analysis purpose (peak transient risk or cumulative fluence),
the confidence (percentile) level required, the duration class
assumed, and the shielding-relevant threshold energy.
- Determine the duration class the analysis purpose requires (a
worst-day duration for peak-risk assessments; a mission-life
duration for cumulative-fluence assessments) and verify the case's
assumed duration class matches it; flag a mismatch rather than
evaluating a spectrum that does not answer the analysis question.
- Evaluate the FLUMIC differential electron energy spectrum for each
of the case's belt regions at the case's confidence level and
duration class.
- Integrate each region's spectrum above the case's threshold energy
to obtain the region's contribution to the shielding-relevant
electron flux.
- Sum the per-region contributions to obtain the case's total
flux above threshold; a belt-crossing orbit must include every
region it crosses, not just the one with the higher reference flux.
- Mark the case compliant only when its duration class matches what
its analysis purpose requires, and roll every case's compliance
into the internal-charging input record; do not hand a
duration-mismatched spectrum to the internal-charging assessment.
Pitfalls
- Using a mission-life duration class for a peak transient-risk
assessment (or a worst-day duration class for a cumulative-fluence
assessment), which understates peak risk or overstates cumulative
fluence because the two exposure-duration classes answer different
questions.
- Evaluating only the outer-belt spectrum for an orbit that also
dwells in the inner belt, dropping a real contribution to the
shielding-relevant flux.
- Using the full differential spectrum (or the flux at a single
energy) in place of the integral flux above the shielding-relevant
threshold energy, which does not represent the electrons actually
capable of causing deep-dielectric charging.
- Treating FLUMIC and the NASA worst-case GEO spectrum as
interchangeable rather than complementary worst-case bounds that the
internal-charging assessment (sibling e1004-internal-charging leaf)
must consider together.
Behavior contract (gate 3)
The region selection, confidence/duration scaling, spectrum
evaluation, threshold integration, and duration-class compliance logic
is exercised by the gate 3 contract test:
scripts/test_e1004_b4_flumic.py against scripts/e1004_b4_flumic_logic.py
(stdlib unittest, offline). Run:
python3 scripts/test_e1004_b4_flumic.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: e1004-b4-flumic3description: "Use when implementing the FLUMIC outer/inner radiation belt worst-case trapped electron model under ECSS-E-ST-10-04C Annex B.4: select the belt region (inner belt, outer belt, or both for a belt-crossing orbit), apply the confidence (percentile) level and the worst-case exposure-duration class the analysis purpose requires, evaluate the resulting electron energy spectrum, and integrate the flux above a shielding-relevant threshold energy for internal (deep-dielectric) charging design. Trigger: FLUMIC, worst-case electron spectrum, outer belt, inner belt, internal charging, deep dielectric charging, trapped electrons, Annex B.4, e-st-10-04, ecss, space environment, radiation belt model."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/e1004-b4-flumic15 domain: space-systems16 subdomain: ecss17 tags: [ecss, e-st-10-04c, flumic, trapped-electrons, internal-charging, radiation-belt, annex-b4]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS FLUMIC Worst-Case Trapped Electron Model (space-systems/ecss/e1004-b4-flumic)2324Use when the task is implementing the FLUMIC worst-case trapped25electron model under ECSS-E-ST-10-04C Annex B.4, to bound the electron26energy spectrum in the outer radiation belt (including geostationary27altitudes) and the inner belt for internal (deep-dielectric) charging28design.2930## Domain quick reference3132- FLUMIC characterizes the trapped electron environment as a33 worst-case energy spectrum rather than a long-term average: it34 answers "how bad can the electron flux get" for a stated confidence35 level and exposure duration, which is the input internal-charging36 analyses need, not the mission-average flux the long-term belt37 models (sibling e1004-trapped-leo, e1004-geo-ige, e1004-meo-meov238 leaves) provide.39- The model spans two distinct belt regions with different reference40 spectra: the outer belt (harder spectrum, extending to higher41 electron energies, dominant driver of GEO and outer-belt internal42 charging risk) and the inner belt (softer spectrum). An orbit that43 crosses both regions needs the combined contribution of both.44- "Worst case" is only meaningful relative to a confidence (percentile)45 level and an exposure-duration class: a short duration class46 (a single worst day) bounds transient peak flux for peak-risk47 assessments, while a long duration class (the mission life) gives48 the appropriate cumulative-fluence bound -- these are not49 interchangeable, and picking the wrong one for the analysis purpose50 gives a spectrum that does not answer the question being asked.51- Internal (deep-dielectric) charging risk depends on the flux of52 electrons energetic enough to penetrate typical shielding and53 deposit charge in dielectric materials, so the assessment needs the54 integral flux above a shielding-relevant threshold energy, not the55 full differential spectrum.56- This leaf scopes the FLUMIC spectral evaluation and threshold57 integration only. Rolling FLUMIC together with the NASA worst-case58 GEO electron spectrum into an internal-charging assessment is the59 sibling e1004-internal-charging leaf (clause 9.2.1.3); the NASA60 worst-case GEO spectrum itself is the sibling e1004-b5-geo-wc leaf61 (Annex B.5).6263## Workflow64651. For each internal-charging case, record its belt region(s)66 (inner belt, outer belt, or both, from the orbit's belt crossings),67 its analysis purpose (peak transient risk or cumulative fluence),68 the confidence (percentile) level required, the duration class69 assumed, and the shielding-relevant threshold energy.702. Determine the duration class the analysis purpose requires (a71 worst-day duration for peak-risk assessments; a mission-life72 duration for cumulative-fluence assessments) and verify the case's73 assumed duration class matches it; flag a mismatch rather than74 evaluating a spectrum that does not answer the analysis question.753. Evaluate the FLUMIC differential electron energy spectrum for each76 of the case's belt regions at the case's confidence level and77 duration class.784. Integrate each region's spectrum above the case's threshold energy79 to obtain the region's contribution to the shielding-relevant80 electron flux.815. Sum the per-region contributions to obtain the case's total82 flux above threshold; a belt-crossing orbit must include every83 region it crosses, not just the one with the higher reference flux.846. Mark the case compliant only when its duration class matches what85 its analysis purpose requires, and roll every case's compliance86 into the internal-charging input record; do not hand a87 duration-mismatched spectrum to the internal-charging assessment.8889## Pitfalls9091- Using a mission-life duration class for a peak transient-risk92 assessment (or a worst-day duration class for a cumulative-fluence93 assessment), which understates peak risk or overstates cumulative94 fluence because the two exposure-duration classes answer different95 questions.96- Evaluating only the outer-belt spectrum for an orbit that also97 dwells in the inner belt, dropping a real contribution to the98 shielding-relevant flux.99- Using the full differential spectrum (or the flux at a single100 energy) in place of the integral flux above the shielding-relevant101 threshold energy, which does not represent the electrons actually102 capable of causing deep-dielectric charging.103- Treating FLUMIC and the NASA worst-case GEO spectrum as104 interchangeable rather than complementary worst-case bounds that the105 internal-charging assessment (sibling e1004-internal-charging leaf)106 must consider together.107108## Behavior contract (gate 3)109110The region selection, confidence/duration scaling, spectrum111evaluation, threshold integration, and duration-class compliance logic112is exercised by the gate 3 contract test:113scripts/test_e1004_b4_flumic.py against scripts/e1004_b4_flumic_logic.py114(stdlib unittest, offline). Run:115python3 scripts/test_e1004_b4_flumic.py116117## Compliance118119- ECSS standards are freely downloadable (ESA); cite the source and120 paraphrase per standards-map.yaml.121- compliance: STANDARDS-REF, gated: false.