ECSS Solar Proton Fluence — ESP Model (space-systems/ecss/e1004-sep-fluence)
Use when the task is ECSS-E-ST-10-04C clause 9.2.2.2 and Annex B.6: computing the cumulative solar proton fluence a mission must design against, using the ESP (Emission of Solar Protons) statistical model, for a stated confidence level and mission duration.
Domain quick reference
- Solar particle events (SPEs) are stochastic: how many events occur, and how large each one is, varies unpredictably from cycle to cycle. The ESP model does not predict individual events; it gives the cumulative proton fluence (integral flux above a stated energy threshold, accumulated over the whole mission duration) that is exceeded with a stated probability (1 minus the confidence level).
- Two independent inputs drive the result: the mission duration (in years of solar-particle-event exposure to be covered) and the confidence level (the probability that the true cumulative fluence stays at or below the computed value). Both must be fixed by the project's radiation requirement before the model is run — the model does not choose them.
- For a fixed confidence level, fluence increases with mission duration: a longer exposure window can accumulate more events. For a fixed duration, fluence increases with confidence level: demanding a smaller probability of exceedance costs a larger design value. A fluence result that violates either trend for otherwise-identical inputs indicates a model or input error, not a valid result.
- The fluence is threshold-specific: it is reported per proton energy threshold (for example >10 MeV, >30 MeV, >60 MeV, >100 MeV). Because integral flux above a higher energy threshold can only be less than or equal to the integral flux above a lower one (protons counted above the higher threshold are a subset of those above the lower one), the fluence spectrum across thresholds must be non-increasing with increasing threshold energy.
- The ESP model's historical database spans a limited number of solar cycles; confidence levels pushed very close to 100% extrapolate well beyond the observed event population and carry materially larger statistical uncertainty than mid-range confidence levels (for example 80-95%). This leaf treats the underlying ESP numeric coefficients as an external, pluggable model call (implemented by the sibling Annex B.6 leaf, e1004-b6-esp) and focuses on selecting valid inputs, invoking that model per threshold, and verifying the result is self-consistent before it is handed to the radiation environment specification (sibling e1004-rad-env-spec).
- This leaf covers cumulative fluence only. Worst-case single-event peak flux (for single-event-effect analyses) is a separate concern, covered by sibling leaf e1004-sep-peakflux; do not substitute one for the other.
Workflow
- Fix the two policy inputs from the project's radiation requirement: mission_duration_years (the exposure period to cover) and confidence_level_pct (the required probability of non-exceedance). Validate both with validate_mission_duration and validate_confidence_level before proceeding.
- Fix the list of energy thresholds (MeV) the radiation environment specification needs (driven by the parts/shielding analyses that consume this data, for example total-dose or SEE thresholds).
- For each threshold, call compute_threshold_fluence, which invokes the pluggable ESP model function (model_fn) for that threshold, duration, and confidence level, and checks the returned fluence is a finite, non-negative number.
- Assemble the full spectrum with compute_fluence_spectrum, which also checks the non-increasing-with-energy invariant across thresholds and reports any violation instead of silently accepting an inconsistent spectrum.
- Before accepting the spectrum for a given duration/confidence policy, spot-check the model's monotonic trends with check_confidence_monotonicity (fluence must not decrease as confidence level increases, duration held fixed) and check_duration_monotonicity (fluence must not decrease as duration increases, confidence level held fixed).
- Combine steps 3-5 with sep_fluence_specification to produce the fluence entry for the mission's radiation environment specification; do not hand a spectrum to e1004-rad-env-spec unless every consistency check in the result passed.
Pitfalls
- Running the ESP model with a duration or confidence level that was never actually approved in the project's radiation requirement, instead of ones fixed by that requirement.
- Accepting a fluence spectrum where a higher energy threshold reports a larger fluence than a lower one — a sign of a threshold mix-up or a broken model call, not a real result.
- Treating an extreme confidence level (for example 99.9%) as free of extra uncertainty; the ESP model's short historical baseline makes such values far less reliable than mid-range confidence levels.
- Confusing cumulative mission fluence (this leaf) with worst-case single-event peak flux (e1004-sep-peakflux) — they answer different design questions and are not interchangeable.
- Hardcoding the ESP model's numeric coefficients into this workflow leaf instead of delegating to the dedicated Annex B.6 implementation (e1004-b6-esp) via the model_fn hook.
Behavior contract (gate 3)
The input-validation, spectrum-assembly, and monotonicity-check logic is exercised by the gate 3 contract test: scripts/test_e1004_sep_fluence.py against scripts/e1004_sep_fluence_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1004_sep_fluence.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.