ECSS Solar Particle Peak Flux for SEE Worst Case (space-systems/ecss/e1004-sep-peakflux)
Use when the task is ECSS-E-ST-10-04C clause 9.2.2.3 solar energetic particle (SEP) peak-flux analysis: computing a JPL-type worst-case peak proton flux to feed a single event effect (SEE) rate worst-case analysis, as distinct from the mission-duration fluence analysis of clause 9.2.2.2.
Domain quick reference
- ECSS-E-ST-10-04C §9.2.2 splits SEP proton environment analysis into two distinct products: §9.2.2.2 computes mission-duration integrated fluence with the ESP model (for cumulative degradation and total dose), while §9.2.2.3 computes a short-duration worst-case peak flux with JPL-type models (for SEE rate worst-case analysis). The two are not interchangeable: SEE rates depend on the instantaneous flux during the worst part of an event, not the total fluence over the mission.
- JPL-type peak-flux models are conventionally expressed as an integral flux above a proton energy threshold, at a stated confidence level (the probability that the true worst-case peak flux will not be exceeded). Higher confidence levels correspond to larger (more conservative) peak-flux magnitudes.
- SEE worst-case analyses use standard proton energy channels chosen to cover the device's SEE-sensitive energy or LET threshold; the channel used must be at least as energetic as the device threshold.
- The peak flux is only meaningful over a short worst-case window (on the order of the peak period of a large event, not the whole mission). An analysis window stretched out to mission duration should instead use the §9.2.2.2 fluence model.
Workflow
- Confirm the analysis purpose actually calls for a peak-flux model with peak_flux_applicable; if the purpose is cumulative degradation or total dose, redirect to the e1004-sep-fluence (ESP) leaf instead.
- Select the standard proton energy channel that covers the device's SEE-sensitive energy threshold with select_energy_channel.
- Compute the worst-case integral peak flux at the project's stated confidence level with integral_peak_flux.
- Classify the worst-case analysis window with worst_case_window_check; a window longer than the short-duration peak-flux window means the fluence model applies instead.
- Combine steps 1-4 with peakflux_worst_case_verdict to get the overall applicability status, selected channel, and computed peak flux before handing the result to the SEE rate calculation.
Pitfalls
- Using a peak-flux (JPL-type) result where a fluence (ESP) result was needed, or vice versa — they answer different questions (SEE rate vs. cumulative degradation).
- Selecting an energy channel below the device's actual SEE-sensitive threshold, understating the flux relevant to the device.
- Quoting a peak flux at one confidence level while the project's worst-case policy specifies another.
- Applying a peak-flux number to a mission-duration window instead of the short worst-case period it represents.
Behavior contract (gate 3)
The applicability, channel-selection, peak-flux, and window-check logic is exercised by the gate 3 contract test: scripts/test_e1004_sep_peakflux.py against scripts/e1004_sep_peakflux_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1004_sep_peakflux.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.