ECSS Human Factors Engineering — Display Design (space-systems/ecss/e1011-displays)
Use when the task is to design or verify that displays on a crewed spacecraft interface satisfy the Human Factors Engineering (HFE) design requirements of ECSS-E-ST-10-11C §4.9.4, covering display format properties, information density limits, and alarm presentation rules.
Domain quick reference
§4.9.4 governs three separable design dimensions that must each be assessed before a display is accepted. Format addresses the physical and visual layout properties of the display itself: the layout type, font size, and luminance contrast between text and background. Information density addresses how much content is placed on a single display: the number of parameters shown simultaneously and the number of alarms visible at one time. Alarm presentation addresses each individual alarm entry: its priority level, its current state, and whether the cueing characteristics match what that priority and state require.
Display format requirements set minimum thresholds rather than exact values, because the thresholds may be tightened by a project's human interface specification. The defaults used here (font size ≥ 10 pt, contrast ratio ≥ 4.5) reflect the HFE floor for crew-readable text under operational lighting conditions. The layout type must be drawn from the set of approved types (list, graphical, schematic, alphanumeric, combined); an ad-hoc layout not in that set is a format finding.
Information density limits are project-configurable but must be explicitly set. The defaults (maximum 15 parameters per display, maximum 12 visible alarms per display) reflect the HFE cognitive-load guideline for continuous monitoring tasks. Exceeding either limit is a density finding even if no individual parameter or alarm is erroneous.
Alarm entries are each categorized by priority and state before their cueing characteristics are checked. Priority levels form an ordered set: advisory < caution < warning < emergency. High-priority active alarms (warning or emergency) require both visual distinctiveness and an auditory signal; lower-priority active alarms require visual distinctiveness at minimum. Suppressed alarms at any priority must carry a visible suppression indicator so that operators know a condition has been masked. Emergency- priority alarms cannot enter the suppressed state; if that combination appears in the alarm register it is an immediate finding, not a suppression check.
Workflow
Obtain the display register (one entry per display: display identifier, layout type, font size, contrast ratio) and the density register (parameter count and visible-alarm count per display, with project limits). Collect the alarm register (one entry per alarm: alarm identifier, priority, state, visual-distinctiveness flag, auditory-signal flag, suppression-visible flag).
For each display entry, check format: (a) the display identifier is non-empty; (b) the layout type is in the approved set; (c) the font size meets or exceeds the project minimum (default 10 pt); (d) the contrast ratio meets or exceeds the project minimum (default 4.5). Record a finding for each check that fails.
For each display entry, check density: (a) the parameter count does not exceed the project maximum (default 15); (b) the visible alarm count does not exceed the project maximum (default 12). Record a finding for each limit that is exceeded.
For each alarm entry, check presentation: (a) priority is from the approved set; (b) state is from the approved set; (c) if the state is 'active' and the priority is 'warning' or 'emergency', visual_distinct and auditory_distinct must both be true; (d) if the priority is 'emergency', the state must not be 'suppressed'; (e) if the state is 'suppressed', suppression_visible must be true. Record a finding for each check that fails.
Aggregate format findings, density findings, and alarm findings across the entire register. A display is not compliant until every finding in all three categories is resolved. Report the total finding count and the per-item breakdown.
Re-run the checks after any corrective action and confirm the finding count reaches zero before closing the review.
Pitfalls
Checking alarm cueing only for 'emergency' state and missing 'warning' priority items — the high-priority cueing threshold applies at 'warning' and above. A warning-priority active alarm with no auditory signal fails even if its visual indicator is prominent.
Reading a 'suppressed' alarm as inactive and skipping its suppression- visible check — a suppressed alarm is still a live condition; the suppression indicator is the only crew notification that the condition exists in a masked state. Omitting the check can leave operators unaware of masked faults.
Treating 'acknowledged' the same as 'normal' for cueing purposes — acknowledgment confirms operator awareness but does not remove the condition. An acknowledged 'warning' alarm still requires its visual indicator to remain active; only the auditory signal may be cleared on acknowledgment.
Accepting a density count that reaches the project limit in normal operations and then exceeds it during alarm floods — the density check applies to the maximum simultaneously visible count, which should be evaluated against a credible alarm flood scenario, not just the nominal display state.
Allowing an emergency alarm to enter the 'suppressed' state on the grounds that a suppress action was procedurally authorised — the HFE rule is unconditional: emergency alarms are always visible. The finding is recorded regardless of how the suppression was initiated.
Behavior contract (gate 3)
The display format, density, and alarm-presentation logic are exercised by the gate 3 contract test: scripts/test_e1011_displays.py against scripts/e1011_displays_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1011_displays.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.