ECSS Human Factors — Environmental Ergonomics (space-systems/ecss/e1011-env-ergonomics)
Use when the task is the environmental ergonomics assessment of a crewed
space habitat or EVA station under ECSS-E-ST-10-11 §4.6.5 — checking noise,
vibration, lighting, cabin atmosphere, thermal environment, and EVA suit
atmosphere against the defined limits for each domain.
Domain quick reference
Environmental ergonomics in ECSS-E-ST-10-11 §4.6.5 spans six domains, each
with its own metric and limit set.
- Noise — A-weighted sound pressure level (dB(A)) compared against area
type limits: 55 dB(A) for inhabited operational areas, 50 dB(A) for sleep
quarters, and 85 dB(A) for short-term intermittent exposure (< 15 min/day).
Warning alarms must exceed the local background level by at least 10 dB.
- Vibration — Frequency-weighted whole-body RMS acceleration (m/s²,
ISO 2631-1 basis). The daily action value for exposures ≥ 1 h is 0.5 m/s²;
for exposures < 1 h the limit rises to 1.0 m/s².
- Lighting — Illuminance (lux) matched to the area function: 300–500 lux
for visual-task areas, ≥ 100 lux for general habitable zones, ≥ 10 lux for
emergency lighting, and ≤ 50 lux for sleep quarters (adjustable to darkness).
- Atmosphere — Four parameters are evaluated simultaneously: total cabin
pressure (70.3–101.3 kPa), oxygen partial pressure (19.5–23.1 kPa), CO₂
partial pressure (≤ 0.70 kPa continuous), and relative humidity (25–75 %).
Each parameter carries its own finding; all four must pass.
- Temperature — Operative temperature (18–26 °C), radiant asymmetry
between the warmest and coolest surface visible to the occupant (≤ 10 °C
delta), and mean air velocity at the occupant position (≤ 0.20 m/s).
- EVA suit atmosphere — Internal suit pressure (25–101.3 kPa), O₂ mole
fraction (≥ 0.21), and suit CO₂ partial pressure (≤ 1.0 kPa). These
limits are independent of the cabin atmosphere checks.
A station passes environmental ergonomics only when every domain returns
compliant; a partial-pass is not a pass.
Workflow
- Identify every crewed zone or EVA station to be assessed and assign each
zone an area type (task, general, emergency, sleep) and an exposure type
(continuous, sleep, intermittent).
- For each zone, measure or obtain the six domain inputs: noise SPL, vibration
RMS, illuminance, atmospheric composition, temperature metrics, and (for EVA
stations) suit atmosphere parameters.
- Run the noise check per zone: compare the A-weighted SPL against the limit
for its exposure type; flag any excess and separately verify alarm audibility
margin where alarms are fitted.
- Run the vibration check: apply the short-duration limit (< 1 h) or the 8-h
reference value as appropriate; report the axis and duration alongside any
finding.
- Run the lighting check: verify illuminance falls within the range defined for
the zone's area type; flag both under-illumination and over-illumination for
task and sleep areas.
- Run the atmosphere check with all four parameters in a single call; accumulate
findings for each parameter that falls outside its range.
- Run the temperature check: verify operative temperature, radiant asymmetry,
and air velocity independently; accumulate any findings.
- For EVA stations, run the EVA suit atmosphere check: pressure, O₂ fraction,
and suit CO₂; accumulate findings.
- Aggregate all domain findings per zone. A zone is ergonomically compliant
only when every domain's finding list is empty. Report the count of non-
compliant zones and list each outstanding finding to drive corrective action.
Pitfalls
- Applying the 8-h vibration limit to a short-duration exposure understates
the allowable level; the short-exposure limit (1.0 m/s²) is higher than the
8-h reference and should not be treated as equivalent.
- Treating the CO₂ check as passed when only a single reading is below the
limit — the limit is for continuous exposure; a single sample from a quiescent
period can mask a transient peak that exceeds the threshold.
- Using photopic illuminance alone and neglecting glare or luminance contrast
— the ECSS check covers the illuminance level, but a surface that meets the
lux value while introducing high luminance contrast around displays can still
impair visual performance.
- Running the EVA suit atmosphere check against cabin-atmosphere limits — the
EVA suit CO₂ limit (1.0 kPa) is more permissive than the habitable-area
continuous limit (0.70 kPa); applying the cabin limit to the suit gives a
false non-compliance for nominal suit operations.
- Treating radiant asymmetry as a single absolute temperature rather than the
differential between the warmest and coolest radiant surface — only the delta
is compared against the 10 °C limit, not either surface temperature in
isolation.
Behavior contract (gate 3)
The noise, vibration, lighting, atmosphere, temperature, and EVA suit logic
is exercised by the gate 3 contract test:
scripts/test_e1011_env_ergonomics.py against
scripts/e1011_env_ergonomics_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e1011_env_ergonomics.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: e1011-env-ergonomics3description: "Use when assess environmental ergonomics for a crewed space habitat or EVA station under ECSS-E-ST-10-11 §4.6.5: evaluate noise sound-pressure levels against habitable-area and sleep-quarter limits, verify whole-body vibration doses against daily exposure thresholds, confirm illuminance levels suit each operational area type, check atmospheric pressure, oxygen and carbon-dioxide partial pressures, and humidity against habitable limits, verify operative temperature and radiant-asymmetry boundaries, and audit EVA suit internal atmosphere for pressure, oxygen fraction, and CO₂ concentration. Trigger: ecss, e-st-10-system-scope, human-factors, environmental-ergonomics, noise, vibration, lighting, atmosphere, eva."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/e1011-env-ergonomics15 domain: space-systems16 subdomain: ecss17 tags: [ecss, e-st-10-system-scope, human-factors, environmental-ergonomics, noise, vibration, lighting, atmosphere, eva]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Human Factors — Environmental Ergonomics (space-systems/ecss/e1011-env-ergonomics)2324Use when the task is the environmental ergonomics assessment of a crewed25space habitat or EVA station under ECSS-E-ST-10-11 §4.6.5 — checking noise,26vibration, lighting, cabin atmosphere, thermal environment, and EVA suit27atmosphere against the defined limits for each domain.2829## Domain quick reference3031Environmental ergonomics in ECSS-E-ST-10-11 §4.6.5 spans six domains, each32with its own metric and limit set.3334- **Noise** — A-weighted sound pressure level (dB(A)) compared against area35 type limits: 55 dB(A) for inhabited operational areas, 50 dB(A) for sleep36 quarters, and 85 dB(A) for short-term intermittent exposure (< 15 min/day).37 Warning alarms must exceed the local background level by at least 10 dB.38- **Vibration** — Frequency-weighted whole-body RMS acceleration (m/s²,39 ISO 2631-1 basis). The daily action value for exposures ≥ 1 h is 0.5 m/s²;40 for exposures < 1 h the limit rises to 1.0 m/s².41- **Lighting** — Illuminance (lux) matched to the area function: 300–500 lux42 for visual-task areas, ≥ 100 lux for general habitable zones, ≥ 10 lux for43 emergency lighting, and ≤ 50 lux for sleep quarters (adjustable to darkness).44- **Atmosphere** — Four parameters are evaluated simultaneously: total cabin45 pressure (70.3–101.3 kPa), oxygen partial pressure (19.5–23.1 kPa), CO₂46 partial pressure (≤ 0.70 kPa continuous), and relative humidity (25–75 %).47 Each parameter carries its own finding; all four must pass.48- **Temperature** — Operative temperature (18–26 °C), radiant asymmetry49 between the warmest and coolest surface visible to the occupant (≤ 10 °C50 delta), and mean air velocity at the occupant position (≤ 0.20 m/s).51- **EVA suit atmosphere** — Internal suit pressure (25–101.3 kPa), O₂ mole52 fraction (≥ 0.21), and suit CO₂ partial pressure (≤ 1.0 kPa). These53 limits are independent of the cabin atmosphere checks.5455A station passes environmental ergonomics only when every domain returns56compliant; a partial-pass is not a pass.5758## Workflow59601. Identify every crewed zone or EVA station to be assessed and assign each61 zone an area type (task, general, emergency, sleep) and an exposure type62 (continuous, sleep, intermittent).632. For each zone, measure or obtain the six domain inputs: noise SPL, vibration64 RMS, illuminance, atmospheric composition, temperature metrics, and (for EVA65 stations) suit atmosphere parameters.663. Run the noise check per zone: compare the A-weighted SPL against the limit67 for its exposure type; flag any excess and separately verify alarm audibility68 margin where alarms are fitted.694. Run the vibration check: apply the short-duration limit (< 1 h) or the 8-h70 reference value as appropriate; report the axis and duration alongside any71 finding.725. Run the lighting check: verify illuminance falls within the range defined for73 the zone's area type; flag both under-illumination and over-illumination for74 task and sleep areas.756. Run the atmosphere check with all four parameters in a single call; accumulate76 findings for each parameter that falls outside its range.777. Run the temperature check: verify operative temperature, radiant asymmetry,78 and air velocity independently; accumulate any findings.798. For EVA stations, run the EVA suit atmosphere check: pressure, O₂ fraction,80 and suit CO₂; accumulate findings.819. Aggregate all domain findings per zone. A zone is ergonomically compliant82 only when every domain's finding list is empty. Report the count of non-83 compliant zones and list each outstanding finding to drive corrective action.8485## Pitfalls8687- Applying the 8-h vibration limit to a short-duration exposure understates88 the allowable level; the short-exposure limit (1.0 m/s²) is higher than the89 8-h reference and should not be treated as equivalent.90- Treating the CO₂ check as passed when only a single reading is below the91 limit — the limit is for continuous exposure; a single sample from a quiescent92 period can mask a transient peak that exceeds the threshold.93- Using photopic illuminance alone and neglecting glare or luminance contrast94 — the ECSS check covers the illuminance level, but a surface that meets the95 lux value while introducing high luminance contrast around displays can still96 impair visual performance.97- Running the EVA suit atmosphere check against cabin-atmosphere limits — the98 EVA suit CO₂ limit (1.0 kPa) is more permissive than the habitable-area99 continuous limit (0.70 kPa); applying the cabin limit to the suit gives a100 false non-compliance for nominal suit operations.101- Treating radiant asymmetry as a single absolute temperature rather than the102 differential between the warmest and coolest radiant surface — only the delta103 is compared against the 10 °C limit, not either surface temperature in104 isolation.105106## Behavior contract (gate 3)107108The noise, vibration, lighting, atmosphere, temperature, and EVA suit logic109is exercised by the gate 3 contract test:110scripts/test_e1011_env_ergonomics.py against111scripts/e1011_env_ergonomics_logic.py (stdlib unittest, offline). Run:112python3 scripts/test_e1011_env_ergonomics.py113114## Compliance115116- ECSS standards are freely downloadable (ESA); cite the source and117 paraphrase per standards-map.yaml.118- compliance: STANDARDS-REF, gated: false.