ECSS Human Factors Engineering — Labels and Cues (space-systems/ecss/e1011-labels-cues)
Use when the task is to verify that labels, colour codings, and warning cues on a crewed spacecraft interface satisfy the Human Factors Engineering (HFE) design requirements of ECSS-E-ST-10-11C §4.7.3.
Domain quick reference
§4.7.3 governs two distinct marking types that must each be checked separately. A label is a text string placed adjacent to a control, display, or panel item to identify it unambiguously. A cue is a perceptible signal — colour-coded indicator, auditory tone, or tactile feedback — that conveys system status or alerts the crew to an event requiring attention. Every marking on the interface is categorized as one or the other before its compliance is checked; an uncategorized marking is a gap.
Label requirements address legibility and content: the label text must be non-empty, must use consistent approved terminology (no ad-hoc abbreviations), and must not exceed the character-length limit established in the HFE requirements (50 characters is the default ceiling; a project may tighten this). A label that identifies the wrong item or duplicates an adjacent label name is an ambiguity finding, not just a content finding.
Colour coding follows a fixed HFE status convention. Each colour maps to exactly one status class and must not be repurposed: red indicates danger/emergency conditions; amber or yellow indicates caution/advisory conditions; green indicates nominal or safe conditions; white or grey indicates information or inactive state; blue indicates a selected or active state in some interface conventions. An indicator whose colour contradicts its stated status intent is a convention violation and must be corrected before the interface can be accepted.
Warning cues must be perceptible under operational conditions (lighting, noise, suit-glove limitations). For items with criticality level 'warning' or 'emergency', a single-modality cue is insufficient; at least two independent modalities (chosen from visual, auditory, tactile/haptic) are required so that a failure in one modality channel does not eliminate the alert. Non-critical and caution-level items may use a single modality, but the cue must still be confirmed detectable.
Criticality levels form an ordered set: non-critical < caution < warning < emergency. The redundant-cueing threshold applies at 'warning' and above.
Workflow
Obtain the interface marking inventory (label register and cue register). Categorize every entry as a label or a cue. Flag any entry with no categorization before proceeding; uncategorized entries are not checked against either ruleset and represent a coverage gap.
For each label, check: (a) the label text is non-empty; (b) the text length is within the project character limit (default 50 chars); (c) the item identifier is non-empty and unique within the inventory. Record a finding for each failed check; a label passes only when all three are clear.
For each colour-coded indicator, identify the colour and the intended status. Look up the colour in the HFE convention map. If the colour is not in the approved palette, record an unknown-colour finding. If it is in the palette but the mapped status class does not match the stated status intent, record a convention-violation finding. Amber and yellow are treated as equivalent (both map to caution).
For each warning cue, verify: (a) at least one cueing modality is specified; (b) the modalities are drawn from the approved set (visual, auditory, tactile, haptic); (c) the cue is confirmed detectable in the operational environment; (d) for criticality 'warning' or 'emergency', at least two distinct modalities are listed. Record a finding for each check that fails.
Aggregate all label findings, colour findings, and cue findings. A panel or interface area is not compliant until every finding in all three categories is resolved. Report the total finding count and the per-item breakdown.
Re-run the checks after any corrective action and confirm the finding count reaches zero before closing the review.
Pitfalls
Accepting a label that falls within the character limit but uses an unapproved abbreviation — the length check and the terminology check are independent; passing one does not imply passing the other.
Treating amber and yellow as different status classes — the HFE convention maps both to caution; using one colour in a caution context and then the other for a different caution item does not create a conflict, but mixing them with a third status class (e.g. treating yellow as nominal and amber as caution) is a convention violation.
Assuming a non-detectable cue at 'non-critical' level is acceptable — detectability is mandatory regardless of criticality. A cue that cannot be perceived by the crew in the expected operational environment provides no information and must be redesigned or relocated.
Applying the two-modality rule only to 'emergency' items and missing 'warning' items — the threshold is at 'warning' and above. A warning-level cue with a single visual indicator fails even if the visual is bright and unambiguous.
Leaving entries in the marking inventory with no categorization and reading the check results as complete — only categorized entries are checked. Uncategorized entries are silently excluded, which can mask entire panels from the review.
Behavior contract (gate 3)
The label validation, colour-convention check, and warning-cue redundancy logic are exercised by the gate 3 contract test: scripts/test_e1011_labels_cues.py against scripts/e1011_labels_cues_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1011_labels_cues.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.