ECSS Human Factors — Electronic Mannequin Verification (space-systems/ecss/e1011-mannequin)
Use when the task is the fit, reach, and visibility verification of crewed
spacecraft workstations using electronic mannequins and digital human models
(DHMs) per ECSS-E-ST-10-11C §4.5.2 — establishing which bounding
anthropometric population cases to run, positioning the mannequin at each
workstation, and checking each check type (fit clearance, functional reach,
visibility cone) against its acceptance criterion.
Domain quick reference
- §4.5.2 requires fit, reach, and visibility to be verified against a
representative anthropometric population range. The two bounding cases
that bracket the design space are the 95th-percentile male (largest body
— worst case for fit/clearance) and the 5th-percentile female (smallest
body — worst case for reach and visibility from a low-eye-point).
Both cases must pass before a workstation is accepted; using only the
50th-percentile male is a common but non-compliant shortcut.
- Fit check: the available linear clearance dimension must exceed the
mannequin stature by at least the required margin (typically 50 mm
minimum). Clearance is measured along the constrained axis — usually
vertical for seated overhead panels, lateral for corridor pass-through.
- Reach check: the distance from the mannequin's shoulder reference point
to each target control or connector must not exceed the mannequin's
functional reach. Functional reach is shorter than arm length because it
accounts for torso stability constraints in microgravity; use the
population-specific functional reach, not the full arm length.
- Visibility check: each critical display or indicator must lie within the
mannequin's visibility cone (typically ±55 degrees from the forward eye
axis for comfortable eye rotation without head movement) and must have an
unobstructed sightline. A structurally clear angle that is still blocked
by an intermediate panel, harness, or equipment box is a visibility
failure regardless of the angular value.
Workflow
- Identify every workstation or habitable volume to be verified and list
the check types required for each (fit, reach, visibility, or all three).
Reject any check-type string that is not one of those three before
proceeding.
- For each workstation, determine the bounding anthropometric cases: fit
checks require the 95th-percentile male; reach checks require the
5th-percentile female; visibility checks require both because the eye
point height and cone origin differ between the two bounds.
- Retrieve the anthropometric parameters (stature and functional reach)
for each bounding case from the approved population table. Reject any
(sex, percentile) combination not in that table rather than interpolating.
- Run the fit check: compute the clearance margin (available clearance minus
mannequin stature). The workstation passes fit if the margin meets or
exceeds the required minimum margin. Record the margin value whether it
passes or fails.
- Run the reach check: compute the shortfall (target distance minus
functional reach). The workstation passes reach if the shortfall is zero
or negative. Record the shortfall value whether it passes or fails.
- Run the visibility check: confirm the sightline angle to each critical
display is within the accepted cone limit AND that no obstruction blocks
the sightline. A display fails visibility if either condition is violated;
both must be true for a pass.
- Aggregate the three check results for the workstation. The workstation
is verified only when fit, reach, and visibility all pass for all
required bounding cases. Produce a per-workstation summary listing each
check result and the measured value.
Pitfalls
- Running only one anthropometric bound for a check type that requires both
— visibility checks must use both 95th-male and 5th-female eye points
because head clearance differs and can change which displays are obstructed.
- Using full arm length instead of functional reach for the reach check —
in microgravity the occupant cannot brace against a fixed surface, so
functional reach is the correct limiting parameter and is consistently
shorter than geometric arm length.
- Passing the clearance margin as zero or unset and reading "no violation"
as compliant — an unset margin means the required fit budget was never
captured, which is itself a finding.
- Treating an angular check that passes as automatically free of obstruction
— the obstruction check is independent of the cone angle check; both must
pass separately for visibility to be accepted.
- Applying the 50th-percentile male as the sole population case — this is
the most frequently cited non-compliance in DHM reviews and fails §4.5.2
because it covers neither the fit-bounding nor the reach-bounding extreme.
Behavior contract (gate 3)
The anthropometric lookup, fit-clearance, reach-shortfall, visibility-cone,
and full-workstation-verification logic is exercised by the gate 3 contract
test: scripts/test_e1011_mannequin.py against
scripts/e1011_mannequin_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e1011_mannequin.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: e1011-mannequin3description: "Use when verify fit, reach, and visibility of crewed spacecraft workstations and habitable volumes using electronic mannequins and digital human models, per ECSS-E-ST-10-11C §4.5.2. Select the bounding anthropometric population percentiles (5th-female for minimum reach, 95th-male for maximum envelope), position the mannequin at each defined workstation, evaluate clearance against the required fit margin, check whether each control target lies within the functional reach envelope, and confirm each critical display falls within the accepted visibility cone without obstruction. Flag any station where fit margin, reach shortfall, or obstruction check fails. Trigger: ecss, e-st-10-11c, e-st-10-system-scope, mannequin, digital-human-model, fit-verification, reach-envelope, visibility-check, anthropometry, crewed-spacecraft."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/e1011-mannequin15 domain: space-systems16 subdomain: ecss17 tags: [ecss, e-st-10-11c, e-st-10-system-scope, mannequin, digital-human-model, fit-verification, reach-envelope, visibility-check, anthropometry]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Human Factors — Electronic Mannequin Verification (space-systems/ecss/e1011-mannequin)2324Use when the task is the fit, reach, and visibility verification of crewed25spacecraft workstations using electronic mannequins and digital human models26(DHMs) per ECSS-E-ST-10-11C §4.5.2 — establishing which bounding27anthropometric population cases to run, positioning the mannequin at each28workstation, and checking each check type (fit clearance, functional reach,29visibility cone) against its acceptance criterion.3031## Domain quick reference3233- §4.5.2 requires fit, reach, and visibility to be verified against a34 representative anthropometric population range. The two bounding cases35 that bracket the design space are the 95th-percentile male (largest body36 — worst case for fit/clearance) and the 5th-percentile female (smallest37 body — worst case for reach and visibility from a low-eye-point).38 Both cases must pass before a workstation is accepted; using only the39 50th-percentile male is a common but non-compliant shortcut.40- Fit check: the available linear clearance dimension must exceed the41 mannequin stature by at least the required margin (typically 50 mm42 minimum). Clearance is measured along the constrained axis — usually43 vertical for seated overhead panels, lateral for corridor pass-through.44- Reach check: the distance from the mannequin's shoulder reference point45 to each target control or connector must not exceed the mannequin's46 functional reach. Functional reach is shorter than arm length because it47 accounts for torso stability constraints in microgravity; use the48 population-specific functional reach, not the full arm length.49- Visibility check: each critical display or indicator must lie within the50 mannequin's visibility cone (typically ±55 degrees from the forward eye51 axis for comfortable eye rotation without head movement) and must have an52 unobstructed sightline. A structurally clear angle that is still blocked53 by an intermediate panel, harness, or equipment box is a visibility54 failure regardless of the angular value.5556## Workflow57581. Identify every workstation or habitable volume to be verified and list59 the check types required for each (fit, reach, visibility, or all three).60 Reject any check-type string that is not one of those three before61 proceeding.622. For each workstation, determine the bounding anthropometric cases: fit63 checks require the 95th-percentile male; reach checks require the64 5th-percentile female; visibility checks require both because the eye65 point height and cone origin differ between the two bounds.663. Retrieve the anthropometric parameters (stature and functional reach)67 for each bounding case from the approved population table. Reject any68 (sex, percentile) combination not in that table rather than interpolating.694. Run the fit check: compute the clearance margin (available clearance minus70 mannequin stature). The workstation passes fit if the margin meets or71 exceeds the required minimum margin. Record the margin value whether it72 passes or fails.735. Run the reach check: compute the shortfall (target distance minus74 functional reach). The workstation passes reach if the shortfall is zero75 or negative. Record the shortfall value whether it passes or fails.766. Run the visibility check: confirm the sightline angle to each critical77 display is within the accepted cone limit AND that no obstruction blocks78 the sightline. A display fails visibility if either condition is violated;79 both must be true for a pass.807. Aggregate the three check results for the workstation. The workstation81 is verified only when fit, reach, and visibility all pass for all82 required bounding cases. Produce a per-workstation summary listing each83 check result and the measured value.8485## Pitfalls8687- Running only one anthropometric bound for a check type that requires both88 — visibility checks must use both 95th-male and 5th-female eye points89 because head clearance differs and can change which displays are obstructed.90- Using full arm length instead of functional reach for the reach check —91 in microgravity the occupant cannot brace against a fixed surface, so92 functional reach is the correct limiting parameter and is consistently93 shorter than geometric arm length.94- Passing the clearance margin as zero or unset and reading "no violation"95 as compliant — an unset margin means the required fit budget was never96 captured, which is itself a finding.97- Treating an angular check that passes as automatically free of obstruction98 — the obstruction check is independent of the cone angle check; both must99 pass separately for visibility to be accepted.100- Applying the 50th-percentile male as the sole population case — this is101 the most frequently cited non-compliance in DHM reviews and fails §4.5.2102 because it covers neither the fit-bounding nor the reach-bounding extreme.103104## Behavior contract (gate 3)105106The anthropometric lookup, fit-clearance, reach-shortfall, visibility-cone,107and full-workstation-verification logic is exercised by the gate 3 contract108test: scripts/test_e1011_mannequin.py against109scripts/e1011_mannequin_logic.py (stdlib unittest, offline). Run:110python3 scripts/test_e1011_mannequin.py111112## Compliance113114- ECSS standards are freely downloadable (ESA); cite the source and115 paraphrase per standards-map.yaml.116- compliance: STANDARDS-REF, gated: false.