ECSS HFE — Off-Duty Stations (space-systems/ecss/e1011-offduty)
Use when the task is to design or verify off-duty crew accommodations aboard a crewed spacecraft under ECSS-E-ST-10-11C §4.7.7 — covering sleep quarters, personal hygiene facilities, and recreation areas, each with its own parameter set that must satisfy HFE requirements before the station is considered compliant.
Domain quick reference
- §4.7.7 groups off-duty provisions into three station types, each with distinct design criteria: sleep (privacy, acoustic isolation, lighting controllability, thermal comfort, physical restraint), hygiene (fluid containment, water delivery rate, physical accessibility, handholds for microgravity use), and recreation (communication link to ground, adequate exercise volume, suitable lighting for leisure and exercise tasks).
- Each station type is evaluated against its own parameter set; a sleep parameter (e.g. acoustic attenuation) is not carried over to the hygiene check and vice versa. Mixing parameter sets across station types produces invalid results.
- Sleep station lighting must span the full range from 0 lux (full dark for sleep onset) up to a task-lighting maximum; both bounds are checked separately. A station that cannot achieve full dark fails the sleep-lighting requirement even if its maximum level is within bounds.
- All three station types use a boolean presence check for critical system features (restraint system, privacy screen, waste containment, communication link). A feature present but set to False is treated the same as a missing feature — it must be True to pass.
- Missing parameters are tracked separately from out-of-bound findings so that a station with a gap in its design record is not read as compliant merely because no numeric violation was computed.
Workflow
- Identify every off-duty station in the spacecraft design record and assign each a station type (sleep, hygiene, or recreation). Reject any station whose type is not one of these three — do not guess or default; return an error and request clarification before continuing.
- For each sleep station, collect and check: acoustic attenuation (dB), minimum and maximum achievable lighting (lux), minimum and maximum design temperature (°C), crew personal volume (m³), and boolean presence of a restraint system and a privacy screen. Flag each parameter that is absent or outside its bound.
- For each hygiene station, collect and check: water flow rate (mL/min), boolean presence of a waste containment system, accessibility rating (1–5 scale, minimum 3), and handhold count (minimum 2). Flag each parameter that is absent or outside its bound.
- For each recreation station, collect and check: boolean availability of a communication link to ground, exercise envelope volume (m³, minimum 10), and lighting level (lux, minimum 300). Flag each parameter that is absent or outside its bound.
- Aggregate findings and missing parameters per station. A station is HFE-compliant only when both lists are empty. Report the total station count, the compliant count, and the per-station finding lists so the design team can act on each gap individually.
- If all stations in the set are compliant, report overall compliance. If any station fails, the set is not compliant — partial compliance is not an accepted outcome; every station must individually pass.
Pitfalls
- Treating a boolean feature as compliant when its value is False because the key is present in the design record — the requirement is that the system is operational (True), not merely mentioned.
- Checking only the maximum lighting level for a sleep station and missing that the minimum achievable level must reach full dark (0 lux) — a station that cannot dim below 5 lux fails the sleep requirement regardless of its ceiling.
- Applying sleep-station acoustic or volume thresholds to a hygiene or recreation station — each station type has its own parameter set and bounds; cross-applying them produces false findings or false passes.
- Reading an empty findings list as compliant when the missing list is non-empty — a station with unset parameters has incomplete data, not no violations.
- Aggregating numeric parameters across station types (e.g., summing volumes across all three types) — each parameter is local to its station record.
Behavior contract (gate 3)
The station-type validation, per-type parameter bounds checking, boolean presence checks, missing-parameter tracking, and set-level aggregation logic are exercised by the gate 3 contract test: scripts/test_e1011_offduty.py against scripts/e1011_offduty_logic.py (stdlib unittest, offline, deterministic). Run: python3 scripts/test_e1011_offduty.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.