ECSS Space Environment — TID Assessment (space-systems/ecss/e1012-tid-assessment)
Use when the task is to calculate total ionising dose (TID) damage for
electronic components under ECSS-E-ST-10-12C §7.5 — deriving radiation
damage parameters (§7.5.1), computing the accumulated ionising dose with
shielding and margin (§7.5.2), and recording a pass/fail finding per component.
Domain quick reference
- §7.5.1 establishes the radiation damage parameters: each component is
grouped into a category (standard, rad-tolerant, rad-hard, rad-hardened)
defined by its maximum TID tolerance in rad(Si). The category is the
anchor for the dose limit comparison and is derived from the component
manufacturer's radiation characterisation data, not assumed.
- §7.5.2 defines the ionising dose calculation: the environment model
provides an orbit- and shielding-dependent dose rate (krad/year behind
a specified aluminium sphere equivalent). Accumulated TID equals the dose
rate multiplied by the mission duration; a design margin (typically 2×)
is then applied to obtain the radiation design requirement for each
location. The margin accounts for uncertainties in the environment model,
shielding geometry, and dose enhancement effects.
- The assessment finds a component non-compliant when its dose design
requirement (TID × margin) exceeds its category limit. A component is
not automatically compliant simply because no limit was recorded — a
missing limit is itself a finding requiring resolution before the
assessment closes.
Workflow
- Identify the mission orbit and nominal aluminium shielding thickness
at each component location. Confirm that a dose rate is available for
that orbit–shielding pair from the environment analysis; reject
undefined combinations before proceeding.
- Derive the radiation damage parameters for each component: assign it
to a category (standard / rad-tolerant / rad-hard / rad-hardened) from
its characterisation data and record the associated TID limit in rad(Si).
Flag any component without a characterised limit as needing resolution.
- Compute the accumulated TID at each location: multiply the dose rate
(krad/year) by the mission duration (years) and convert to rad.
- Apply the design margin to the computed TID to obtain the radiation
design requirement for each component location.
- Compare each component's design requirement against its category TID
limit. Record a compliant or non-compliant finding; do not carry
forward a component with a missing limit as compliant.
- Collect all findings per component location; the location is not TID
compliant until every component at that location produces a compliant
finding and no limit gaps remain.
Pitfalls
- Applying the dose rate directly as the TID without multiplying by
mission duration — the rate is per year, not the total accumulated dose.
- Omitting the design margin before comparing against the limit — comparing
raw TID to the limit understates the requirement and can produce a false
pass when the environment and geometry uncertainties are unaccounted for.
- Treating a missing TID limit as equivalent to an unlimited tolerance —
absence of characterisation data is a gap in the damage parameter set,
not a licence to proceed.
- Using aluminium shielding thickness as a direct proxy for dose without
confirming the orbit–shielding lookup is valid — an interpolated or
extrapolated dose rate outside the environment table's range propagates
unquantified error into every downstream comparison.
Behavior contract (gate 3)
The damage-parameter grouping, TID computation, margin application, and
pass/fail assessment logic is exercised by the gate 3 contract test:
scripts/test_e1012_tid_assessment.py against
scripts/e1012_tid_assessment_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e1012_tid_assessment.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: e1012-tid-assessment3description: "Use when calculate total ionising dose (TID) damage for spacecraft4 electronic components under ECSS-E-ST-10-12C §7.5: derive the applicable radiation5 damage parameters for each component category (§7.5.1), compute the accumulated6 ionising dose from orbit-specific dose rates and mission duration using an aluminium7 shielding model (§7.5.2), apply the required design margin, and compare each8 component's dose requirement against its TID limit to produce a compliant or9 non-compliant finding. Trigger: ecss, e-st-10-12c, e-st-10-system-scope,10 tid, total-ionising-dose, radiation-damage, dose-calculation, shielding, rha,11 component-assessment."12license: Apache-2.013compliance: STANDARDS-REF14standards:15 - id: ecss16 reference-only: true17gated: false18domain: space-systems19pack: space-systems20compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"21metadata:22 source: https://skillmd.com/skills/ashfordeou/e1012-tid-assessment23 domain: space-systems24 subdomain: ecss25 tags: [ecss, e-st-10-12c, e-st-10-system-scope, tid, total-ionising-dose, radiation-damage, dose-calculation, shielding, rha, component-assessment]26 version: 0.1.027 author: Aero Agent Skills28---2930# ECSS Space Environment — TID Assessment (space-systems/ecss/e1012-tid-assessment)3132Use when the task is to calculate total ionising dose (TID) damage for33electronic components under ECSS-E-ST-10-12C §7.5 — deriving radiation34damage parameters (§7.5.1), computing the accumulated ionising dose with35shielding and margin (§7.5.2), and recording a pass/fail finding per component.3637## Domain quick reference3839- §7.5.1 establishes the radiation damage parameters: each component is40 grouped into a category (standard, rad-tolerant, rad-hard, rad-hardened)41 defined by its maximum TID tolerance in rad(Si). The category is the42 anchor for the dose limit comparison and is derived from the component43 manufacturer's radiation characterisation data, not assumed.44- §7.5.2 defines the ionising dose calculation: the environment model45 provides an orbit- and shielding-dependent dose rate (krad/year behind46 a specified aluminium sphere equivalent). Accumulated TID equals the dose47 rate multiplied by the mission duration; a design margin (typically 2×)48 is then applied to obtain the radiation design requirement for each49 location. The margin accounts for uncertainties in the environment model,50 shielding geometry, and dose enhancement effects.51- The assessment finds a component non-compliant when its dose design52 requirement (TID × margin) exceeds its category limit. A component is53 not automatically compliant simply because no limit was recorded — a54 missing limit is itself a finding requiring resolution before the55 assessment closes.5657## Workflow58591. Identify the mission orbit and nominal aluminium shielding thickness60 at each component location. Confirm that a dose rate is available for61 that orbit–shielding pair from the environment analysis; reject62 undefined combinations before proceeding.632. Derive the radiation damage parameters for each component: assign it64 to a category (standard / rad-tolerant / rad-hard / rad-hardened) from65 its characterisation data and record the associated TID limit in rad(Si).66 Flag any component without a characterised limit as needing resolution.673. Compute the accumulated TID at each location: multiply the dose rate68 (krad/year) by the mission duration (years) and convert to rad.694. Apply the design margin to the computed TID to obtain the radiation70 design requirement for each component location.715. Compare each component's design requirement against its category TID72 limit. Record a compliant or non-compliant finding; do not carry73 forward a component with a missing limit as compliant.746. Collect all findings per component location; the location is not TID75 compliant until every component at that location produces a compliant76 finding and no limit gaps remain.7778## Pitfalls7980- Applying the dose rate directly as the TID without multiplying by81 mission duration — the rate is per year, not the total accumulated dose.82- Omitting the design margin before comparing against the limit — comparing83 raw TID to the limit understates the requirement and can produce a false84 pass when the environment and geometry uncertainties are unaccounted for.85- Treating a missing TID limit as equivalent to an unlimited tolerance —86 absence of characterisation data is a gap in the damage parameter set,87 not a licence to proceed.88- Using aluminium shielding thickness as a direct proxy for dose without89 confirming the orbit–shielding lookup is valid — an interpolated or90 extrapolated dose rate outside the environment table's range propagates91 unquantified error into every downstream comparison.9293## Behavior contract (gate 3)9495The damage-parameter grouping, TID computation, margin application, and96pass/fail assessment logic is exercised by the gate 3 contract test:97scripts/test_e1012_tid_assessment.py against98scripts/e1012_tid_assessment_logic.py (stdlib unittest, offline). Run:99python3 scripts/test_e1012_tid_assessment.py100101## Compliance102103- ECSS standards are freely downloadable (ESA); cite the source and104 paraphrase per standards-map.yaml.105- compliance: STANDARDS-REF, gated: false.