Use when the task is to establish the TID assessment basis for a spacecraft electronics programme, following ECSS-E-ST-10-12C §7.1–7.4 — determining which ionising-dose environments are active for the mission orbit, grouping device technologies by their TID sensitivity, and setting the minimum qualification test level before any detailed dose calculation begins.
Domain quick reference
- §7.1 defines the purpose of the TID assessment: to confirm that each electronic part will survive the accumulated ionising dose over the mission lifetime, including all required margins, before the design is frozen. The assessment basis is the set of inputs that must be fixed before the dose calculation is performed: orbit, mission duration, shielding configuration, device-technology list, and margin factors.
- §7.2 identifies the environments that contribute to TID by orbit regime. LEO missions accumulate dose primarily from trapped protons (inner belt) and trapped electrons (outer belt) with their secondary bremsstrahlung. MEO sits inside the peak of both belts and is the most intense regime. GEO missions see outer-belt electrons and solar energetic protons (SEP) but are outside the inner belt. HEO missions cross the belts during apogee passes and add SEP exposure at high altitude. Interplanetary missions are dominated by SEP and galactic cosmic rays (GCR) with no belt contribution. GCR contributes a low but non-negligible TID to all mission types.
- §7.3 and Table 7-1 group device technologies by TID sensitivity. Bipolar linear ICs and opto-couplers carry high sensitivity; some bipolar devices also exhibit enhanced low dose-rate degradation (ELDRS), requiring testing at a representative low dose-rate rather than at the accelerated rate used for other technologies. CMOS bulk, power MOSFETs, and CMOS SOI carry moderate sensitivity. GaAs MESFETs, HEMTs, passive components, and quartz oscillators carry low sensitivity. A technology's sensitivity level determines the rigour of the dose-rate test protocol and the scrutiny applied to margin allocation.
- §7.4 fixes the minimum TID test level at margin_factor × design_dose, where margin_factor must be at least 2.0 for standard programmes. The design dose is the environment-predicted total dose at the part location (including shielding) over the full mission duration.
Workflow
- Identify the orbit type and mission duration. Reject any orbit type that does not fall within the recognised set (LEO, MEO, GEO, HEO, interplanetary) before proceeding — an unrecognised orbit has no mapped environment contributors and cannot support a valid basis.
- Retrieve the TID-contributing environments for the orbit from the environment map (§7.2 analogue). Record each contributor with its key and description so the basis record is traceable. All contributors must be accounted for; omitting bremsstrahlung in a MEO mission, for example, understates the shielding requirement.
- List every device technology in scope for the programme. For each one, look up its TID sensitivity level (high/moderate/low) from the technology table (§7.3 / Table 7-1 analogue). Flag any technology not found in the programme database as a finding that must be resolved before the basis is accepted — an unknown technology cannot be grouped, so its margin requirement is undefined.
- For each high-sensitivity bipolar technology, add a finding that low dose-rate (ELDRS) testing is required per §7.3. This finding does not block basis acceptance but must appear in the assessment plan.
- Apply the margin factor (minimum 2.0) to the design dose to derive the minimum TID qualification test level. Reject any margin factor below 2.0 with an explicit error — reducing the margin below the floor requires a formal tailoring request, which is outside the scope of the standard assessment basis workflow.
- Assemble the TID basis record: orbit type, mission duration, environment list, technology entries with sensitivity levels, minimum test level, margin factor, and findings list. Mark the record complete only when no unknown-technology or incomplete-assessment findings remain and the minimum test level is positive. An incomplete record must not advance to dose calculation.
Pitfalls
- Omitting GCR from the environment list because its TID contribution is small — GCR is always present and must appear in the basis; its contribution is small but not zero, and it is the dominant source for very long interplanetary missions in deep solar minimum.
- Treating all technologies as equivalent sensitivity and applying a single flat test level — the sensitivity grouping in §7.3 / Table 7-1 exists precisely to tailor the dose-rate protocol; collapsing the groups either over-tests low-sensitivity passives or under-tests ELDRS-prone bipolar devices.
- Accepting a margin factor below 2.0 without a recorded tailoring justification — §7.4 sets 2.0 as the floor for a reason: it absorbs environment-model uncertainty and part-to-part variation simultaneously. Silently accepting a lower value invalidates the qualification argument.
- Proceeding to dose calculation before all technologies are resolved in the database — an unresolved technology has no sensitivity grouping and no applicable dose-rate protocol, leaving the assessment with an uncharacterised exposure risk.
- Omitting bremsstrahlung as a separate contributor in electron-dominated orbits (GEO, MEO) — bremsstrahlung from trapped electrons penetrates shielding differently than primary particles and must be listed so the transport calculation includes it.
Behavior contract (gate 3)
The environment-identification, technology-sensitivity-grouping, minimum-test-level derivation, and basis-record assembly logic is exercised by the gate 3 contract test: scripts/test_e1012_tid_basis.py against scripts/e1012_tid_basis_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1012_tid_basis.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.