ECSS Interface Management — Interface Definition (space-systems/ecss/e1024-definition)
Use when the task is to define the interfaces of a space system element per ECSS-E-ST-10-24C §5.4 — establishing the IDD or single-end ICD content for geometry, signals, protocols, and per-end resource budgets.
Domain quick reference
- ECSS-E-ST-10-24C §5.4 requires every interface end to carry four attribute groups before the interface can be submitted to the controlled baseline: geometry (mounting point, envelope dimensions, mass), signals or protocols (signal type, voltage, impedance, or protocol name, data rate, message format), and budget (allocated resource vs. capacity with margin). An interface end without all applicable groups is incomplete and must not be baselined.
- Interface types recognised by this leaf: mechanical (geometry only), electrical and optical (geometry + signals), data (geometry + protocols + budget), fluid and thermal (geometry + budget). Each type maps to a fixed set of required attribute groups; supplying groups beyond those required is permitted but does not satisfy missing ones.
- Budget compliance requires allocated ≤ capacity and capacity > 0. The margin percentage is (capacity − allocated) / capacity × 100. A surface with an unset budget on a budget-bearing interface type is a finding, not a pass.
- For electrical and optical interfaces, both ends of a two-end pair must carry the same signal type and compatible voltage levels (within 0.5 V tolerance). A mismatch is a compatibility finding that blocks the IDD from being complete.
Workflow
- Collect every interface end from the IDD or single-end ICD record. Reject
any end whose
end_idis absent or blank, and any end whoseinterface_typeis not one of the recognised types listed above. - For each end, determine which attribute groups are required by its interface type. Check that each required group (geometry, signals, protocols, budget) is present as a structured block with all mandatory fields populated.
- For every budget block, evaluate compliance: confirm
allocatedandcapacityare numeric,capacity> 0,allocated≥ 0, andallocated≤capacity. Record the margin percentage. Flag any exceedance or missing field. - For electrical and optical end pairs, verify signal type identity and voltage compatibility across the two ends. Record any mismatch as a compatibility finding.
- Aggregate per-end findings and cross-end compatibility findings. The IDD is complete only when both lists are empty for every end.
- Emit a structured result:
completeflag, per-end finding lists, compatibility findings, and a one-line summary. An incomplete IDD must not be submitted to the interface control baseline.
Pitfalls
- Treating budget absence as a non-issue for data, fluid, or thermal interfaces — an interface end of those types with no budget block is incomplete, not implicitly compliant.
- Collapsing electrical and mechanical geometry requirements — mechanical ends do not require a signals block; electrical ends do. Applying the same attribute set to all types produces false findings on mechanical ends and false passes on electrical ends.
- Accepting a voltage difference below 0.5 V as always safe — the tolerance is an engineering default; project-specific requirements may be tighter. Flag such pairs and defer to the project's electrical interface budget.
- Baselined IDD records with unresolved findings — the §5.4 check must be clean before the record enters configuration control, not after.
Behavior contract (gate 3)
The geometry, signals, protocols, budget, signal-compatibility, and full-IDD logic is exercised by the gate 3 contract test: scripts/test_e1024_definition.py against scripts/e1024_definition_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1024_definition.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.