ECSS Interface Management — ICD DRD Compliance (space-systems/ecss/e1024-icd-drd)
Use when the task is to generate or validate an Interface Control Document against the Data Requirements Document (DRD) defined in ECSS-E-ST-10-24C Annex B — identifying interface pairs, categorizing interface types, confirming mandatory section coverage, tracing requirements to parent documents, and verifying that each interface requirement has an assigned verification method.
Domain quick reference
- ECSS-E-ST-10-24C Annex B defines the DRD for the ICD. The ICD describes every interface between two items in a space system: both items in the pair must be explicitly named, and the document must carry a unique identifier and revision mark before any content is considered valid.
- Interface types are drawn from a fixed set: mechanical (structural, kinematic connections), electrical (power, grounding, signal), thermal (heat exchange, thermal coupling), data (communication protocols, data formats), RF (radio-frequency links), optical (light paths, field-of-view interactions), and fluid (propellant, coolant lines). Each interface is categorized into exactly one type; an unrecognized type is a DRD violation.
- Mandatory DRD sections per Annex B are: scope (purpose and boundaries of the interface), reference_documents (IRD, system spec, and other governing documents), interface_description (the technical definition of the interface), and verification_requirements (the set of requirements that must be verified across the interface). An ICD missing any of these sections is non-compliant regardless of the quality of the remaining content.
- Every interface requirement stated in the ICD must trace back to a parent requirement in the Interface Requirements Document (IRD) or in the system-level specification. A requirement without a parent_ref has no top-down authority and must be flagged.
- Each interface requirement must also carry an assigned verification method from the set: analysis, test, inspection, review_of_design. A requirement without a verification method cannot be closed out during verification campaigns.
Workflow
- Check identification completeness: confirm the ICD carries a non-empty icd_id, a revision mark, and an interface_pair with exactly two non-empty item names. Reject any ICD missing these fields before proceeding.
- Categorize each interface type listed in the ICD against the recognized type set. Flag any type not in the set; require at least one type to be declared.
- Verify mandatory section coverage: confirm scope, reference_documents, interface_description, and verification_requirements sections are all present and non-empty. Record a finding for each missing or empty section.
- Check requirement traceability: for each interface requirement, confirm a parent_ref field is present and non-empty. Flag every requirement that lacks a parent reference.
- Verify verification coverage: for each requirement, confirm a verification method is assigned and is drawn from the recognized method set. Flag requirements with a missing or unrecognized method.
- Aggregate all findings. An ICD is DRD-compliant only when the aggregated finding list is empty. Return the full finding list to allow targeted remediation.
Pitfalls
- Accepting an ICD with a single-sided interface_pair (only one item named) as valid — both sides of the interface must be identified; a one-sided entry is ambiguous and cannot be controlled as an interface.
- Skipping the parent_ref check on the grounds that requirements are "obviously derived" — the traceability link must be explicit and on-record in the ICD, not implicit in the engineer's intent.
- Treating an empty mandatory section as present — a section key with no content satisfies the key-presence check but not the DRD content requirement; both must be verified.
- Allowing a custom verification method not in the recognized set — the four ECSS verification methods (analysis, test, inspection, review_of_design) are the only methods recognized for ICD verification closure; custom entries must be mapped to one of the four.
- Reading an empty findings list from a partial check (e.g., only identification checked) as full DRD compliance — all five check steps must complete before the ICD can be declared compliant.
Behavior contract (gate 3)
The identification, interface-type categorization, section-coverage, requirement-traceability, and verification-coverage logic is exercised by the gate 3 contract test: scripts/test_e1024_icd_drd.py against scripts/e1024_icd_drd_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1024_icd_drd.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.