ECSS Interface Management — Generic ICD Structure and Content (space-systems/ecss/e1024-icd-generic)
Use when the task is applying the common structure and content rules of ECSS-E-ST-10-24C §5.7 to any ICD variant (EICD, MICD, or TICD) — checking that each document is structurally complete, that every requirement is bilaterally allocated and traceable to a parent system requirement, and that configuration-control provisions are in place.
Domain quick reference
- ECSS-E-ST-10-24C §5.7 establishes the common structure and content rules that apply to every interface control document regardless of variant. An ICD is valid only when all required sections are present and populated; a document that omits a section is structurally non-conforming even if its individual requirements are well-formed.
- The identification block anchors the document in the project context: it must carry a document number, revision mark, issue date, project name, interface name, and the identities of both the providing and receiving parties. A missing party identity prevents authoritative sign-off and is treated as a structural deficiency, not a content shortfall.
- Each numbered requirement must be traceable upward to at least one parent system-level requirement, must state which deliverable the provider is responsible for and which the requester accepts (bilateral allocation), and must carry a named verification method (test, analysis, inspection, or review of design). A requirement that lacks a parent traceability link or an allocated verification method is incomplete regardless of the correctness of its technical statement.
- Configuration control must be explicit: a named authority responsible for approving changes to the ICD, and a revision history recording the evolution of the document. An ICD without a named authority has no formal change process and cannot be baselined.
Workflow
- Confirm the ICD type (EICD, MICD, TICD, or generic ICD). Reject any document that does not identify its type before proceeding.
- Verify the interface identifier is unique and non-empty. Record the identifier as the primary key for this ICD record in the project interface register.
- Check that all six required sections are present: identification, applicable documents, interface description, requirements, verification, and configuration control. List any missing section as a structural finding before examining content.
- Inspect the identification block for all seven required fields: document number, revision, date, project, interface name, provider, and requester. A blank or absent field in the identification block is a structural finding independent of the requirements content.
- For each requirement entry, confirm: (a) a non-empty requirement ID, (b) a requirement statement, (c) a parent system-level requirement reference, (d) an explicit provider allocation, (e) an explicit requester allocation, and (f) a recognized verification method (test, analysis, inspection, or review of design). Record each missing or unrecognized field as a requirement-level finding keyed to the requirement ID.
- Verify that all requirement IDs within the ICD are unique. A duplicate ID makes the interface register ambiguous and is flagged as a separate finding.
- Check the configuration-control section for a named change authority and a revision history. An ICD with neither field populated cannot be formally baselined.
- Aggregate all findings under four categories: structure findings, identification findings, requirement findings, and configuration findings. The ICD is conformant under §5.7 only when all four categories are empty.
Pitfalls
- Accepting an ICD that has a requirements section but no parent traceability references — the requirements section may be complete in form while every requirement floats unanchored above the system requirement tree. The traceability check is mandatory per §5.7 regardless of how well the requirements are written.
- Skipping the section-presence check and proceeding directly to content review — a section that is absent generates no content findings, creating a false impression of a well-formed document. Always verify section presence first.
- Treating a revision history entry with a blank description as compliant — revision history requires meaningful content (revision mark, date, change description) to serve its configuration-control function; a placeholder row satisfies the structure but not the intent.
- Conflating the verification section (a section of the ICD) with the verification-method field on each requirement — both must be present independently: the section provides the overall verification approach, and each requirement carries its own method assignment.
Behavior contract (gate 3)
The ICD-type validation, interface-id check, section-presence check, identification-block check, requirement-entry check, unique-ID check, and configuration-control check logic is exercised by the gate 3 contract test: scripts/test_e1024_icd_generic.py against scripts/e1024_icd_generic_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e1024_icd_generic.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.