ECSS Electromagnetic Compatibility — Peak Detector Usage (space-systems/ecss/e2007-peak-detector-usage)
Use when the task is the clause 5.2.8.2 obligation of ECSS-E-ST-20-07C: any emission or susceptibility quantity read against frequency is read with the peak detector. The clause is short, and the defect it prevents is quiet — a setup that names the right detector but sweeps too fast for it records a number that is neither the peak nor an honest average.
Domain quick reference
- The detector decides what a single measured point means. A peak detector holds the maximum the resolution-bandwidth filter reached inside that point; an average, root-mean-square or sample detector reports something lower for every signal that is not a steady sine, which is most of what a spacecraft unit emits. Quasi-peak is weighted for human perception of interference and also sits below the peak.
- Naming the detector is only half of it. The peak detector has to be given time to reach a peak. The resolution-bandwidth filter settles in roughly the reciprocal of its bandwidth, so the dwell on each measured point must reach at least that reciprocal before the reading means anything.
- Pulsed emissions raise the bar again. If the unit emits at a repetition rate, a point whose dwell is shorter than the interval between pulses can fall entirely between two of them and record the floor. The governing dwell is the larger of the filter response time and the pulse repetition interval.
- Dwell is derived, not declared. It is the sweep time divided by the number of measured points, so halving the sweep time or doubling the point count both erode it, and a setup can be made non-compliant by a change that looks like a resolution improvement.
- The frequency step between points is a separate trap. A step wider than the resolution bandwidth leaves frequencies no point ever looked at; keeping the step to half the bandwidth or less means a narrow signal always lands inside a measured point.
- The clause covers susceptibility as well as emissions. A susceptibility quantity measured against frequency — the level actually injected or radiated at each point — is read with the same detector, or the applied stress is understated and the unit is graded against a field it never saw.
- A run set is governed by its tightest run: the one whose dwell sits closest to the dwell it needed, not the one with the longest sweep.
Workflow
- Validate each frequency-domain run: an identifier, a recognized purpose (emission or susceptibility), a recognized detector, a positive span, an integer point count of at least two, a positive sweep time, a positive resolution bandwidth, and a positive pulse repetition rate where the emission is pulsed.
- Report any detector other than peak, naming the run and the purpose, since averaging and weighted detectors understate by construction rather than by accident.
- Derive the dwell per measured point from the sweep time and the point count, and the required dwell from the resolution-bandwidth response time, raised to the pulse repetition interval where one is declared.
- Compare the two, absorbing float representation error at equality rather than relaxing the bound, and where the sweep is too fast report the minimum sweep time the point count implies so the setup can be corrected directly.
- Derive the frequency step from the span and the point count and compare it against the allowed fraction of the resolution bandwidth.
- Grade the run: compliant when the detector, the dwell and the step all hold; marginal when it holds but a pulse repetition rate was never declared, so the dwell was sized on the filter alone; otherwise non-compliant.
- Aggregate: counts per category, the governing run by dwell ratio, the findings and the limitations. The set is sound only when no run carries a finding.
Pitfalls
- Accepting a report because the detector field says peak. The detector name and the sweep speed are independent, and a fast sweep defeats a correctly named detector silently.
- Sizing the dwell on the resolution-bandwidth response time for a pulsed emitter. The pulse repetition interval is frequently the longer of the two and is the one that governs.
- Reading the sweep time as the dwell. The dwell is the sweep time shared across every measured point, so a twenty-second sweep over a thousand points gives twenty milliseconds each, not twenty seconds.
- Increasing the point count to improve resolution while holding the sweep time fixed. That shortens the dwell on every point and can turn a compliant setup non-compliant while appearing to refine it.
- Stepping in frequency by more than the resolution bandwidth. The gaps between points are then never measured, and a narrow emission sitting in one is reported as absent.
- Applying the clause to emissions only. Susceptibility levels read against frequency are governed too, and understating the applied level grades the unit against a stress it never received.
- Substituting an average detector to make a noisy trace look cleaner. The trace is cleaner because the peaks the clause asks for have been removed from it.
Behavior contract (gate 3)
The detector normalisation, setup validation, dwell and bin-step derivation, pulse-interval dominance, per-run grading and aggregation logic is exercised by the gate 3 contract test: scripts/test_e2007_peak_detector_usage.py against scripts/e2007_peak_detector_usage_logic.py (stdlib unittest, offline, deterministic). Run: python3 scripts/test_e2007_peak_detector_usage.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.