ECSS Photovoltaic -- Bare Solar Cell Source Control Drawing (space-systems/ecss/e2008-bare-solar-cell-drawing)
Use when the task is the content rule of ECSS-E-ST-20-08C Annex C -- what the source control drawing describing a bare solar cell has to state, and which of the numbers it states are limits anybody could reject a cell against.
Domain quick reference
- The drawing is a list of characteristics, and a characteristic earns its place only when it carries a unit, a limit, and -- if it is electrical -- the conditions the number was measured at. Missing any one of the three, the line looks like a specification and binds nobody.
- A unit is not decoration. A thickness of 150 reads as micrometres to one engineer and as thousandths of an inch to another, and both readings are reasonable until the drawing says which.
- A limit is a minimum, a maximum, a range, or a nominal with a band. A nominal on its own is what the supplier intends today; nothing about it lets anyone reject a cell tomorrow.
- A band whose two ends coincide is the same failure written differently. A range from 2.5 to 2.5, or a nominal with a zero tolerance, names a point no real cell lands on, so it rejects the whole population rather than the bad part of it.
- Electrical numbers are conditional numbers. An open-circuit voltage without the spectrum, the intensity and the temperature behind it came from an unnamed measurement, and two suppliers can both satisfy it while shipping different cells.
- The annex names a floor, not a ceiling. Characteristics beyond the required set are welcome and are graded the same way, but a weak one among them is an open item on a drawing whose required set is sound -- not a reason to stop the release.
- A required characteristic stated as the wrong kind -- a current written up as a physical property with no measurement conditions -- is how a conditional number escapes the condition check, so the kind is graded against the annex rather than taken from the drawing.
- Characteristics do not weigh the same. The three dimensions and the three electrical outputs carry the cell; the coating and the mass matter less. Completeness weighted by what each pins down is the honest number.
Workflow
- Take the drawing as its number and the characteristics it states.
- Resolve each stated limit into bounds: a minimum or a maximum leaves one end open, a range and a nominal-with-tolerance close both, a bare nominal closes neither.
- Mark as degenerate any band whose ends coincide, comparing them with a tolerance rather than with equality.
- For every electrical characteristic, check the spectrum, the intensity and the temperature are all named.
- Grade each characteristic as controlled, open or uncontrolled, and split the uncontrolled ones into those the annex requires and those beyond it.
- Name every required characteristic the drawing never states, and every one it states under the wrong kind.
- Weight the controlled required characteristics by what each pins down and compare the share with the threshold the drawing is released against.
- Disposition the drawing: a missing, uncontrolled or mis-kinded required characteristic, or a share under the threshold, stops the release; a degenerate band or a weak extra characteristic releases it against open items.
Pitfalls
- Reading a precise-looking number as a controlled one. Digits after the decimal point are not a limit.
- Accepting a nominal because a tolerance is "standard shop practice". The practice is not on the drawing and the drawing is what the supplier signs.
- Writing a zero tolerance to mean exact. It rejects every cell that can physically be made.
- Comparing the two ends of a band with equality. They are computed numbers, a band meant to be degenerate can miss by a few units in the last place, and the check quietly passes the thing it exists to catch.
- Quoting an electrical output with no spectrum, intensity or temperature. The number is from an unnamed experiment and cannot be reproduced or disputed.
- Naming two of the three measurement conditions and calling the third obvious. Obvious to the reader is not stated on the drawing.
- Letting an electrical characteristic ride as a physical one. The condition check never runs, and the number keeps looking complete.
- Treating a weak characteristic outside the required set as a stoppage. The annex sets a floor, and grading the extras harder than the required set inverts the standard.
- Counting characteristics instead of weighting them. Eight of nine stated says nothing when the missing one is a cell dimension.
- Comparing a weighted control share with its threshold by bare arithmetic. Both are quotients of weights and a drawing exactly on the threshold can evaluate a few units in the last place under it; the comparison absorbs that while the threshold stays as written.
Behavior contract (gate 3)
The limit-form resolution into bounds, degenerate band detection, measurement condition attachment for electrical characteristics, characteristic grading into controlled, open and uncontrolled, required-versus-extra separation, kind checking, weighted control share and the release disposition are exercised by the gate 3 contract test: scripts/test_e2008_bare_solar_cell_drawing.py against scripts/e2008_bare_solar_cell_drawing_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e2008_bare_solar_cell_drawing.py