ECSS Planar Blocking Diodes -- Marking (space-systems/ecss/e2008-blocking-diode-marking)
Use when the task is clause 12.2.3 of ECSS-E-ST-20-08C: how delivered planar blocking diodes are marked is not a method the standard fixes, it is an approach settled together with the customer. The review therefore starts at the agreement and only then looks at the mark itself.
Domain quick reference
- Agreement is the first requirement, not a wrapper around a technical one. A scheme the supplier picked alone fails the clause however legible, however permanent and however cleverly coded the mark is, because nobody on the receiving side committed to reading it that way.
- Agreement has five standings, not two. A recorded agreement binds, and only if it actually names a document somebody can read it back from. A verbal agreement binds the delivery it was made for and nothing at the next one. A superseded agreement was real once, which is exactly why the difference between the two schemes has to be dispositioned. A proposal nobody answered and a scheme nobody was asked about bind nothing at all.
- An agreement that settles no approach settles nothing, however warmly both sides remember the meeting.
- Once the agreement stands, three physical questions decide whether the approach delivers an identity at all, and they pull against each other on a part this small: fit, retention and granularity.
- Fit is arithmetic, not judgement. An identity code has a character count and a height below which it stops being legible, and the carrier it is written on has a finite face. A code that does not fit is an aspiration.
- Retention is the stage the mark survives to. A label on a shipping carrier stops at incoming inspection: the diode leaves the bag and the identity stays behind. Body marks reach further, and how much further depends on whether the mark survives cleaning, mounting and integration.
- Granularity is what one mark resolves a delivered diode to. A lot bag label resolves it to the whole lot, so a part pulled from the bag carries no identity of its own. Counting a lot label as traceability is how a delivery claims part identity it never had.
- The order of the three matters. A code that does not fit is reported before the retention it would have had, because the mark that was measured cannot be applied in the first place.
Workflow
- Resolve policy: whether a verbal agreement is accepted, the handling stage identity is owed through, and how many diodes one mark may resolve a delivered part to. All three are project positions.
- Grade the agreement standing and check it names a catalogued approach and, where it claims to be recorded, a document to read it back from.
- Size the identity code on the carrier face the agreed approach writes on, at the declared character height or the approach's legible minimum.
- Read how far down handling a mark on that carrier survives, against the stage identity is owed through.
- Count the diodes one mark resolves a delivered part to -- one for a body mark, the package for a carrier label, the lot for a bag label.
- Rank the approach: not agreed first, then a code that does not fit, then retention short, then granularity short.
- Grade every catalogued approach the same way and name the longest-lived workable one as the approach to settle with the customer instead.
- Report the delivery: the agreement standing, the graded approach, the acceptable alternatives and every finding in order.
Pitfalls
- Starting at the mark. A legible, permanent, part-level mark that nobody agreed still fails this clause, and the review that opened with a magnifier never asks the question the clause is actually about.
- Reading a recorded agreement that names no document as recorded. Nothing can be read back from it, so it is a memory rather than an agreement.
- Treating a verbal agreement as binding on the next delivery. It bound the room it was made in, and the next lot is a different room.
- Waving a superseded agreement through. It was the standard once, which is precisely why the delta between the two schemes needs a disposition.
- Reading a lot or package label as part identity. The mark resolves a delivered diode to a population, and the part pulled out of the bag is carrying nothing.
- Checking legibility without checking the face. A character height chosen for readability writes a code wider than the diode it is going on.
- Reporting retention on a code that does not fit. The mark that survives well is one that could never be applied, so the fit finding comes first.
- Assuming the marking face is generous because the carrier is. A planar blocking diode body is millimetres across, and the approach that survives furthest is usually the one with the least room to write on.
- Judging a code footprint that lands exactly on the face by bare arithmetic. The footprint is a sum of products of a character height, so a code laid out to exactly fill its face can evaluate a unit in the last place above it; the comparison absorbs that while the declared face stays as declared.
Behavior contract (gate 3)
The five agreement standings and which of them bind, the code footprint and its fit against the declared carrier face, the legible character height minimum, the handling stage each carrier's mark survives to, the diodes one mark resolves a delivered part to, the ranked approach verdict, the recommended alternative and the rolled-up delivery verdict are exercised by the gate 3 contract test: scripts/test_e2008_blocking_diode_marking.py against scripts/e2008_blocking_diode_marking_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e2008_blocking_diode_marking.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.