ECSS Planar Blocking Diodes -- Failed Components (space-systems/ecss/e2008-failed-blocking-diodes)
Use when the task is clause 12.7.2 of ECSS-E-ST-20-08C: the preceding criteria say what a blocking diode failure mode is, and this clause says what a part showing one becomes. It is a failed blocking diode, and a failed blocking diode is not part of what is delivered. This leaf reads the inspection outcome for each offered part and returns the designation, the evidence that designation owes, and the deliverable count that survives.
Domain quick reference
- One standing mode is enough. Modes do not vote and severity does not dilute, so a part carrying a single listed mode takes the same designation as a part carrying four. What differs is the cause list, not the word.
- The designation is per part. It attaches to the individual diode, not to the procurement lot it came from and not to the subgroup it was drawn into, so a lot that passed its sampling still contains failed components by name.
- Undetermined is a third word and it has to stay a third word. A part whose inspection is unfinished is not deliverable and not failed; collapsing it into either arm converts absent evidence into a decision nobody made.
- A designation without segregation is a word in a report. A failed component needs a segregation record and a non-conformance reference, or nothing on the bench keeps it out of the next delivery, which is exactly how a shorted diode walks back into a shipment and onto a string.
- A blocking diode that was already allocated to a string owes one more piece of paper. The allocation has to be withdrawn as well, because the build paperwork downstream reads the allocation rather than the inspection report, and a failed part left allocated is a part the integrator will go looking for.
- Retest does not quietly restore a part. A clearance stands only where the policy in force admits it and a clearing authority is named, and clearing a mode that was never observed is a data defect rather than good news.
- The deliverable count is derived, never declared. It is what is left once the failed parts are removed, so a count carried over from the offered quantity is wrong by exactly the number that matters.
- A record for a part the lot does not offer is not a typo to correct. It may describe another lot entirely, and rewriting the identifier destroys the only evidence that it did.
Workflow
- Validate the designation policy: whether a segregation record, a non-conformance reference and a string-allocation withdrawal are demanded, whether a retest clearance is admitted at all, whether an undetermined part may still be counted into the delivery, and the failed share the lot may carry.
- Read each part record, refuse a mode outside the recognised set rather than dropping it, and collapse repeated modes to one.
- Apply clearance only where the policy admits it and an authority is named, and reject a clearance naming a mode the inspection never raised.
- Give the part its designation: failed when any mode still stands, undetermined when the inspection is unfinished, deliverable otherwise. A standing mode outranks an unfinished inspection.
- For a failed part, name the missing evidence rather than assuming the paperwork exists, and hold its designation undocumented until it is there. A part with a live string allocation is not handled until that allocation is withdrawn.
- Sweep the offered population: an offered part with no record at all is undetermined, and a record for a part the lot does not offer is reported rather than absorbed.
- Group the parts by designation, take the failed parts out of the deliverable count, weigh the failed share against its allowance, and close on designation-assigned only when every offered part is settled, every failed part is documented and no foreign record is riding along.
Pitfalls
- Weighing the modes. The clause reads a list membership, not a severity score, and a weighted verdict quietly delivers a cracked diode that scored low.
- Applying the designation to the lot. Parts are categorized one at a time, and a lot-level word hides which part has to leave the tray.
- Reporting undetermined as deliverable to keep the count round. It is the one error the delivery note cannot show, and it ships an uninspected part onto a string that depends on it.
- Recording the designation and skipping the segregation. The report is then correct and the shelf is not, which is the failure mode that actually reaches the customer.
- Leaving a failed part allocated to its string. The integrator reads the allocation, not the inspection report, and will go and fetch the part the paperwork still points at.
- Taking a retest as a clearance on its own. Without an admitting policy and a named authority it is a second opinion, not a disposition.
- Quoting the offered quantity as the deliverable count. The count is what is left after the failed parts are removed, and nothing else.
Behavior contract (gate 3)
The designation policy validation, the standing-mode reduction with its clearance rules, the per-part designation with undetermined kept separate, the required failed-component evidence including the string-allocation withdrawal, the foreign and unrecorded part arms, the designation grouping, the derived deliverable count and the failed share against its allowance are exercised by the gate 3 contract test: scripts/test_e2008_failed_blocking_diodes.py against scripts/e2008_failed_blocking_diodes_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e2008_failed_blocking_diodes.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.