ECSS Solar Cell Assemblies — Solar Cell Defects (space-systems/ecss/e2008-sca-solar-cell-defects)
Use when the task is clause 6.4.3.1.4 of ECSS-E-ST-20-08C: where a chip or a nick is allowed to sit on the body of a cell, and how large it is allowed to be. The two halves are separate questions and a screen that runs only one of them passes cells it should not.
Domain quick reference
- Position is decided against the inactive border the cell carries between its physical edge and the start of its active area. A break that stays inside that border has taken nothing the cell was generating with. A break that reaches past it has removed generating area and may have severed a grid finger on the way in.
- Size is decided twice: once per break against a single-defect allowance, and again over the whole cell. Many small breaks are a handling problem upstream even when each one of them passes on its own, and only the cumulative view sees that.
- A corner break is measured on the diagonal, and the diagonal resolved back onto either axis is shorter than the number written down. So a corner tolerates a longer measurement before it touches the active border -- and it carries a tighter area allowance anyway, because the corner is where handling cracks start.
- Depth is not a size, it is a position modifier. A break that goes the whole way through the wafer is a crack starter under thermal cycling rather than a deeper scallop, so the distance it is allowed to come in is tightened before the measurement is compared against it.
- A flake off the face is not connected to an edge, so it is declared by its stand-off and its inward extent, and its reach is the far side of the flake. Its footprint is the whole outline; a broken-out edge scallop is taken at half its bounding box.
- Nothing here is reworkable. The dispositions are accept, refer-for-review and reject, and a rework verdict would invite an operation the article does not allow.
- Four edges, four records. An edge nobody looked at is not an edge with no breaks, so the cell stays open rather than passing.
Workflow
- Derive the cell geometry: the cell area, the active area and the inactive border. Refuse a border that leaves no active area at all.
- Take the examined edge list. Hold the cell open when an edge carries no record, and refuse a break recorded on an edge the record says was never looked at.
- Per break, resolve the reach: straight in for an edge break or a nick, diagonal resolved onto the axis for a corner, stand-off plus extent for a face flake.
- Set the permitted reach from the border, tightened when the break goes through the wafer, and compare the reach against it.
- Reject anything that crossed into the active area, and report how much area it took; refer a break that is past the allowance but still clear.
- Take the footprint and grade it against the single-defect allowance and its review multiple, using the tightened corner allowance at a corner.
- Close with the cell verdict, the cumulative area fraction, the per-edge counts, the identifiers that reached the active area, and the edges that carry no record.
Pitfalls
- Comparing a corner measurement against the edge allowance. The diagonal is not the perpendicular, and a corner break scrapped on that comparison was inside the border the whole time.
- Judging a break on its ingress alone. A shallow scallop 30 mm long has taken far more of the cell than a deep notch 1 mm long, and only the footprint sees it.
- Grading a corner break against the flat-edge area allowance. The corner is the crack initiation site, and the allowance there is deliberately smaller.
- Treating depth as a size term. It does not enter the footprint; it moves the position allowance, and a through break that would pass on area can still be past the distance it is allowed to come in.
- Accepting a cell because every break passed. The cumulative fraction and the per-edge count exist for exactly that case.
- Offering a rework. There is no operation that puts silicon back, so a rework line on a cell body record means the disposition was never made.
- Reading a silent edge as a clean edge. The record says nothing about it, which is not the same as saying it is clean.
- Comparing a measurement with a derived limit by bare arithmetic. The limits are products of a criteria fraction and a measured dimension and the corner reach is resolved through an irrational factor, so a measurement exactly on a limit can evaluate a few units in the last place above it; the comparison absorbs that representation error while the limit stays untouched.
Behavior contract (gate 3)
The reach resolution, the through-wafer tightening, the active-area encroachment rule, the single-defect and corner area allowances, the cumulative fraction, the per-edge crowding check and the examined-edge completeness rollup are exercised by the gate 3 contract test: scripts/test_e2008_sca_solar_cell_defects.py against scripts/e2008_sca_solar_cell_defects_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e2008_sca_solar_cell_defects.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.