E2020 Rlcl Class Selection

Evaluate which retriggerable current limiter class a protected load belongs on. Use when an ECSS-E-ST-20-20C clause 5.2.2.1.1 power design has to take an RLCL class from the project class table and show its performance figures hold under repeated retriggering: derate the continuous rating, form the worst-case retrigger duty from the longest trip-off delay against the shortest hold-off, compare the resulting mean fault current with the harness thermal rating and the per-attempt fault energy with its allowance, count the retrigger attempts a capacitive load needs to finish charging against the class attempt allowance, then take the smallest passing class. Refuses a non-ascending table, an inverted hold-off window and a lower limiting current that leaves nothing to charge the load. Trigger: ecss, e-st-20-20c, rlcl-class-selection, retriggerable-current-limiter, rlcl-retrigger-duty-cycle, rlcl-hold-off-time, rlcl-attempt-allowance, rlcl-fault-energy-per-attempt, harness-thermal-mean-rating.