ECSS Power — RLCL Class Selection (space-systems/ecss/e2020-rlcl-class-selection)
Use when the task is the retriggerable-limiter class choice of ECSS-E-ST-20-20C clause 5.2.2.1.1 — taking one class out of the standard's class table for a protected load and demonstrating that the performance figures attached to that class still hold once the limiter is allowed to close again by itself.
Domain quick reference
- An RLCL behaves like a latching limiter up to the moment it trips. Where a latching unit stays open until it is commanded on, a retriggerable unit waits a hold-off period and closes again on its own, repeating up to a bounded number of attempts before it gives up. Its class row therefore carries two figures a latching class does not: the hold-off window and the attempt allowance.
- Automatic retriggering makes a sustained fault repetitive rather than singular. The harness no longer sees one pulse, it sees a train, so the quantity that matters thermally is the MEAN current set by the retrigger duty cycle. The binding duty is the LONGEST trip-off delay against the SHORTEST hold-off, which is the most conduction per cycle a compliant unit may present.
- Each attempt also dumps an energy pulse into the fault. Bus voltage times upper limiting current times the longest trip-off delay is the per-attempt energy, and it is bounded separately from the mean current: a low duty cycle does not make a large individual pulse acceptable.
- Retriggering is also a start-up mechanism, and this is what separates the RLCL selection from the LCL one. A capacitive load that cannot finish charging inside one trip-off delay can still come up across several attempts. The charging current is the LOWER limiting current minus the load's own steady draw, delivered for the SHORTEST trip-off delay, and only the fraction of charge the load keeps across the hold-off carries into the next attempt. If the lower limiting current does not exceed the steady draw there is no charging current at all and no number of attempts will start the load.
- The attempt count the start-up needs is a selection output in its own right, compared against the class allowance. Consuming most of the allowance just to come up leaves nothing for a genuine transient, so it is worth an advisory even when it passes.
- The smallest adequate class wins: a larger class holds a higher fault current for longer at a comparable duty, so every retrigger train puts more into the same harness for no benefit.
Workflow
- Validate the class table: ascending continuous ratings, unique names, a limiting band above the class's own continuous rating, and trip-off and hold-off windows that are the right way up. Require an integer attempt allowance of at least one — an unbounded retrigger into a hard short is a bus hazard, not a class.
- Validate the load: steady current, capacitance, bus voltage, the peak and thermal ratings of the harness, and the per-attempt fault energy allowance. Refuse a thermal rating that exceeds the peak one.
- Derate each class continuous rating and keep the classes that carry the steady load.
- Form the worst-case retrigger duty from the longest trip-off delay and the shortest hold-off, take the mean fault current from it, and compare against the harness thermal rating.
- Compare the upper limiting current against the harness peak rating, and the per-attempt fault energy against its allowance. These are three separate gates and a class may pass any two of them.
- Count the attempts the load needs to finish charging: accumulate the charge delivered each attempt at the lower limiting current net of the steady draw, apply the declared retention across each hold-off, and stop when the class allowance runs out.
- Take the smallest class that passes every gate; report its duty, mean current, per-attempt energy, attempt count and both harness slacks, and raise an advisory when start-up consumes most of the allowance.
Pitfalls
- Selecting an RLCL the way an LCL is selected. The continuous rating, limiting band and trip-off window are common to both, but ignoring the duty cycle, the per-attempt energy and the attempt allowance drops exactly the three checks that automatic retriggering introduces.
- Forming the duty cycle from the nominal trip-off delay and the nominal hold-off. A compliant unit may sit at the long end of the trip-off window and the short end of the hold-off at the same time, so the worst-case duty is that pairing and nothing gentler.
- Treating the mean current as a substitute for the energy check. The mean says what the harness heats to; the per-attempt energy says what a single pulse does to the fault site and to the switch. A class can pass one and fail the other.
- Charging the load capacitance at the lower limiting current without subtracting the load's own steady draw. The load keeps consuming during the attempt, and when the draw reaches the lower limiting current there is no charging current left at all.
- Assuming charge is kept perfectly across the hold-off. A partially charged load bleeds down while the limiter is open, and a retention fraction below one can turn a two-attempt start-up into one that never converges inside the allowance.
- Comparing a mean current or an energy by bare arithmetic. A case meant to sit exactly on the thermal rating or exactly on the energy allowance can land a few units in the last place above it; the comparison absorbs that representation error while the ratings stay as specified.
Behavior contract (gate 3)
The class-table validation, load validation, worst-case duty cycle, mean fault current, per-attempt fault energy, retrigger start-up attempt count and smallest-adequate selection are exercised by the gate 3 contract test: scripts/test_e2020_rlcl_class_selection.py against scripts/e2020_rlcl_class_selection_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e2020_rlcl_class_selection.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.