ECSS Explosive Subsystems — Materials (space-systems/ecss/e3311-materials)
Use when the task is the material screen of ECSS-E-ST-33-11C clause
4.9 -- choosing what may be in contact with, or enclose, an explosive
charge, given both what the space environment does to the material and
what the material and the charge do to each other.
Domain quick reference
- The screen is a combination question, not two separate ones. A
polymer can pass a vacuum outgassing screen on its own and a charge
can be stable on its own, and the pair can still produce a device
whose composition has been slowly attacked by what the polymer
released into the cavity.
- Vacuum screening produces two numbers and both are graded: total
mass loss says how much left the material, and the condensable
volatile fraction says how much of that will land on something else
and stay there.
- Compatibility is measured with the material against the charge. Gas
evolution says whether the pair is reacting; the depression of the
decomposition onset says whether the pair has made the charge less
stable than it was alone, and that second number is the one that
changes the thermal case.
- Stress-corrosion susceptibility is a property of the alloy and its
temper, and it is a category rather than a measurement. A candidate
outside the allowed category is not simply rejected: with a
justification on record it is retained under restriction, and the
restriction travels with it into the report.
- The temperature rating is graded against the hot case plus the same
margin the thermal case carries, so a material rated exactly at the
predicted temperature is short, not marginal.
- Galvanic coupling is a property of a pair and of the environment
around it, never of a material alone. The same two alloys are an
acceptable couple in a controlled bay and an unacceptable one at a
coastal launch site, so the allowance is read from the environment
the assembly will actually see.
- Contacts are declared, not inferred. A pair nobody wrote down is a
pair nobody graded.
Workflow
- Normalize the candidate list and reject it outright on a duplicate
identifier, a contact naming a material that is not in the list, or
a material declaring contact with itself, because a couple that
cannot be resolved cannot be graded.
- Grade the vacuum figures for each candidate, reporting mass loss
and condensable volatiles as separate findings so a marginal
material is not confused with a badly contaminating one.
- Grade contact-with-charge behaviour: gas evolution against its
limit, then the decomposition-onset depression against its own.
- Grade stress-corrosion susceptibility against the allowed category,
and split the outcome three ways: inside the category, outside but
justified, and outside with nothing on record.
- Grade each temperature rating against the predicted hot case plus
the declared margin.
- Build the contact pairs from the declared contacts, grade each
against the environment's allowance, and close with the accepted,
restricted and rejected groups plus any pair that failed.
Pitfalls
- Screening the material and the explosive separately and declaring
the pair acceptable. The gas evolution and onset numbers only exist
because that inference is unreliable.
- Reading total mass loss as the whole outgassing answer. A material
can lose very little and still deposit enough condensable volatiles
on an optic or a contact to matter; the two limits fail
independently.
- Treating an onset depression of a few kelvin as noise. It moves the
decomposition-onset margin the thermal case was closed against, so
the material choice quietly reopens a check that was already signed.
- Rejecting a moderately susceptible alloy outright, or keeping it
silently. The honest middle is to keep it against a recorded
justification and carry the restriction forward into the report.
- Grading a galvanic couple against one allowance for the whole
programme. The allowance follows the environment, and a couple
qualified in a controlled bay can be unacceptable on the pad.
- Comparing a measurement with its limit by bare arithmetic. A
material sitting exactly on a limit can land a few units in the last
place above it; the comparison absorbs that while the limit stays
untouched.
Behavior contract (gate 3)
The candidate normalization, contact-pair resolution, outgassing,
compatibility, corrosion, service-temperature and galvanic gates, the
per-material grouping and the assembly verdict are exercised by the
gate 3 contract test: scripts/test_e3311_materials.py against
scripts/e3311_materials_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_e3311_materials.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: e3311-materials3description: "Evaluate a material list for an explosive device against ECSS-E-ST-33-11C clause 4.9. Use when the task is deciding which candidates may sit next to a charge and which are out: grading vacuum mass loss and condensable volatiles, grading gas evolution and decomposition-onset depression measured in contact with the explosive, holding stress-corrosion susceptibility to the allowed category unless a justification is on record, checking each temperature rating against the hot case plus margin, and computing the potential difference across every declared contact pair against the allowance its environment carries. Trigger: ecss, e-st-33-11-explosive-subsystem-scope, explosive-material-compatibility, explosive-gas-evolution-limit, explosive-outgassing-screening, explosive-galvanic-couple, stress-corrosion-susceptibility-explosive, decomposition-onset-depression."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/e3311-materials15 domain: space-systems16 subdomain: ecss17 tags: [ecss, e-st-33-11-explosive-subsystem-scope, e3311-materials, explosive-material-compatibility, explosive-gas-evolution-limit, explosive-outgassing-screening, explosive-galvanic-couple, stress-corrosion-susceptibility-explosive, decomposition-onset-depression]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Explosive Subsystems — Materials (space-systems/ecss/e3311-materials)2324Use when the task is the material screen of ECSS-E-ST-33-11C clause254.9 -- choosing what may be in contact with, or enclose, an explosive26charge, given both what the space environment does to the material and27what the material and the charge do to each other.2829## Domain quick reference3031- The screen is a combination question, not two separate ones. A32 polymer can pass a vacuum outgassing screen on its own and a charge33 can be stable on its own, and the pair can still produce a device34 whose composition has been slowly attacked by what the polymer35 released into the cavity.36- Vacuum screening produces two numbers and both are graded: total37 mass loss says how much left the material, and the condensable38 volatile fraction says how much of that will land on something else39 and stay there.40- Compatibility is measured with the material against the charge. Gas41 evolution says whether the pair is reacting; the depression of the42 decomposition onset says whether the pair has made the charge less43 stable than it was alone, and that second number is the one that44 changes the thermal case.45- Stress-corrosion susceptibility is a property of the alloy and its46 temper, and it is a category rather than a measurement. A candidate47 outside the allowed category is not simply rejected: with a48 justification on record it is retained under restriction, and the49 restriction travels with it into the report.50- The temperature rating is graded against the hot case plus the same51 margin the thermal case carries, so a material rated exactly at the52 predicted temperature is short, not marginal.53- Galvanic coupling is a property of a pair and of the environment54 around it, never of a material alone. The same two alloys are an55 acceptable couple in a controlled bay and an unacceptable one at a56 coastal launch site, so the allowance is read from the environment57 the assembly will actually see.58- Contacts are declared, not inferred. A pair nobody wrote down is a59 pair nobody graded.6061## Workflow62631. Normalize the candidate list and reject it outright on a duplicate64 identifier, a contact naming a material that is not in the list, or65 a material declaring contact with itself, because a couple that66 cannot be resolved cannot be graded.672. Grade the vacuum figures for each candidate, reporting mass loss68 and condensable volatiles as separate findings so a marginal69 material is not confused with a badly contaminating one.703. Grade contact-with-charge behaviour: gas evolution against its71 limit, then the decomposition-onset depression against its own.724. Grade stress-corrosion susceptibility against the allowed category,73 and split the outcome three ways: inside the category, outside but74 justified, and outside with nothing on record.755. Grade each temperature rating against the predicted hot case plus76 the declared margin.776. Build the contact pairs from the declared contacts, grade each78 against the environment's allowance, and close with the accepted,79 restricted and rejected groups plus any pair that failed.8081## Pitfalls8283- Screening the material and the explosive separately and declaring84 the pair acceptable. The gas evolution and onset numbers only exist85 because that inference is unreliable.86- Reading total mass loss as the whole outgassing answer. A material87 can lose very little and still deposit enough condensable volatiles88 on an optic or a contact to matter; the two limits fail89 independently.90- Treating an onset depression of a few kelvin as noise. It moves the91 decomposition-onset margin the thermal case was closed against, so92 the material choice quietly reopens a check that was already signed.93- Rejecting a moderately susceptible alloy outright, or keeping it94 silently. The honest middle is to keep it against a recorded95 justification and carry the restriction forward into the report.96- Grading a galvanic couple against one allowance for the whole97 programme. The allowance follows the environment, and a couple98 qualified in a controlled bay can be unacceptable on the pad.99- Comparing a measurement with its limit by bare arithmetic. A100 material sitting exactly on a limit can land a few units in the last101 place above it; the comparison absorbs that while the limit stays102 untouched.103104## Behavior contract (gate 3)105106The candidate normalization, contact-pair resolution, outgassing,107compatibility, corrosion, service-temperature and galvanic gates, the108per-material grouping and the assembly verdict are exercised by the109gate 3 contract test: scripts/test_e3311_materials.py against110scripts/e3311_materials_logic.py (stdlib unittest, offline). Run:111python3 scripts/test_e3311_materials.py112113## Compliance114115- ECSS standards are freely downloadable (ESA); cite the source and116 paraphrase per standards-map.yaml.117- compliance: STANDARDS-REF, gated: false.