ECSS Communications — Data Labelling (space-systems/ecss/e50-data-labelling)
Use when the data a communication system carries has to be labelled, per ECSS-E-ST-50C clause 5.8.2 — whether the label a receiver actually gets is enough to say where a unit came from, where it is going, what it is, when it was made and which one it is.
Domain quick reference
- A label is judged by what a receiver can recover without being told. Anything the ground has to look up in a configuration file is not in the label, however well documented it is elsewhere.
- Five things have to be readable off the unit: source, destination, data type, sequence position and generation time. Each answers a question the others cannot, and a label missing one leaves a question the receiver has to guess at.
- The ground network owes its own version of that test, over every item of data it takes from the spacecraft: a reader of one item has to be able to say which parameter it holds, when the value was sampled on board and when it arrived on the ground, and no two of those items may end up wearing the same label.
- Field width is arithmetic, not judgement. Naming N distinct things takes the bit count that addresses N, and a field one bit short does not carry most of them — it carries half, and aliases the rest onto each other silently.
- Compute those widths with integer bit arithmetic. A count sitting exactly on a power of two is both the case a floating-point logarithm rounds wrong and the case a designer is most likely to have picked, so the two failure modes coincide precisely where it hurts.
- A sequence counter is only useful while it has not wrapped. The design question is not how wide the counter is but whether it repeats inside the window over which two units still have to be told apart — a retransmission window, a store-and-forward gap, a ground retention period.
- The label is paid for out of the payload, every unit, forever. The overhead fraction is the label over the whole unit, and the cheapest way to move it is usually a larger data unit rather than a smaller label.
Workflow
- Take the declared label as named fields with widths in whole bits. Reject a zero-width field, a duplicate name and a non-integer width rather than coercing them.
- Compare the field names against the required set case-insensitively; report present, missing and unrecognised separately, because an unrecognised name is usually a required field under a house name. For data the ground has acquired, run the same comparison against what one item has to yield by itself — the parameter it holds, the time that value was sampled on board, the time it reached the ground — and confirm that no two acquired items can carry identical labels.
- Size each identifier field: the bits needed to address the declared number of distinct sources and destinations, against the bits declared. Report how many things the declared field can actually name.
- Compute the sequence wrap period from the counter width and the unit rate, and compare it with the window over which units must stay distinguishable. Report the narrowest counter that closes the gap.
- Compute the label overhead as a share of the whole data unit and compare it with the allowance under a relative tolerance, so a design landing exactly on the allowance passes everywhere.
- Report the effective payload rate the link delivers after the label, which is the number a data budget actually needs.
- Grade sufficient only when coverage, both identifier widths, the sequence window and the overhead all hold, and give each shortfall a number: the width needed, or the payload size that fits.
Obligations
| Item | Step |
|---|---|
| ECSS-E-ST-50C Rev.2 5.8.2a | 2 |
Pitfalls
- Counting fields instead of reading them. A label with five fields that does not include a generation time is still missing a generation time, and only a set comparison catches it.
- Sizing an identifier from today's node count. Formations grow and data types multiply; a field sized to the exact current count aliases the first addition onto an existing address.
- Using a floating-point logarithm for the bit count. It rounds the power-of-two case the wrong way on some hosts, which is the one case a designer is most likely to have chosen deliberately.
- Treating counter width as the requirement. Width only matters through the wrap period; a wide counter on a fast source can still repeat inside the window, and a narrow one on a slow source may never.
- Quoting link capacity as the data rate. Every unit pays its label, so the delivered payload rate is lower, and a budget built on capacity is short by exactly the overhead fraction.
- Shrinking the label to meet an overhead allowance. Dropping a field or narrowing an identifier buys percentage points by removing the thing the label existed for; a larger data unit costs nothing the receiver needs.
Behavior contract (gate 3)
Label validation including duplicate and zero-width fields, required field coverage with unrecognised names, integer identifier sizing across the power-of-two boundary, the sequence wrap period and the narrowest counter that covers the window, the overhead fraction at its exact allowance and the delivered payload rate are exercised by the gate 3 contract test: scripts/test_e50_data_labelling.py against scripts/e50_data_labelling_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e50_data_labelling.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.