Use when the data transfer services of an on-board network are being sized against the flows they carry, per ECSS-E-ST-50C clause 5.7.2.1 — whether a service exists for each flow, and whether it is the service that flow needed.
Domain quick reference
- One normative item holding two questions, and they are not the same question. One asks that a data transfer service exists for the traffic the network is required to carry. The other asks that the service actually meets what the flow needs. A design can pass the first and fail the second in the same review.
- A flow names the two applications it runs between and states three things about the traffic they exchange: a sustained rate, an upper bound on how long a transfer may take, and whether delivery has to be assured. A service that satisfies two of the three has not served it.
- Adequacy is a property of the service under its whole load. Two flows that each fit a service can together exceed it, so the rate test runs against the aggregate after every flow has been placed, never against the flow on its own.
- Latency and assurance behave the other way round: they are properties of the service alone, so they decide which services a flow may sit on before capacity is looked at.
- Utilisation and spare capacity belong in the report even when nothing failed. A network at ninety-nine percent passes every check and has nowhere to put the next flow the programme adds.
- Assignment has to be deterministic or the report is not reviewable. Largest flow first, best fit by the spare capacity left behind, and the service name as the tie-break gives the same answer on every run.
Workflow
- Declare each service with a name, its sustained capacity, the latency bound it commits to, whether it assures delivery, and whether it returns word to the sender when a data unit could not be delivered at all.
- Declare each flow with a name, the application it starts at, the application it ends at, its rate, its deadline and whether it needs assured delivery. The two application names are what the coverage question is asked about: every pair of applications on the network that has to exchange data units is owed a service able to carry the flow between them, so the pairs have to be on the table before anything is placed. Reject a duplicate name on either side: two entries under one name are two teams sizing the same traffic.
- For each flow, take the services that meet its latency bound and its assurance need. A service meets that need when it either gets the data unit to its destination or tells the sender it could not. Do not filter on capacity here.
- Place the flows largest first, choosing the eligible service that is left with the least spare capacity afterwards.
- Sum the load each service carries once every flow is placed, then compare that aggregate against the service capacity.
- Compare rates and latencies with a relative tolerance. A flow sized to exactly fill a service, or sitting exactly on its latency bound, must come out adequate rather than depend on the build machine.
- Report the two questions separately — coverage and adequacy — with the named flows under each, the utilisation of every service and the rate shortfall where there is one. Walk the pairs declared at step 2 and name every one the service set leaves unable to exchange data units, and any service that neither gets a unit to its destination nor reports the failure back to the sender.
Obligations
| Item | Step |
|---|---|
| ECSS-E-ST-50C Rev.2 5.7.2.1a | 7 |
Pitfalls
- Reporting one verdict for the clause. A flow with no service and a flow on the wrong service are different defects with different owners, and one pass-or-fail line hides which you have.
- Testing rate per flow instead of per service. Every flow fits, the service does not, and the check that looked at them one at a time says the design is fine.
- Treating assured delivery as a nice-to-have that a faster service can substitute for. Rate does not make a lossy path lossless, and a flow that asked for assurance is not served by bandwidth.
- Deciding capacity or latency with a bare inequality. Two arithmetically identical designs can straddle the bound on different platforms, so the verdict changes with the host.
- Leaving assignment implicit. If the report cannot say which service carries which flow, nobody can reproduce the utilisation figures it printed, and the next reviewer starts again.
- Quoting utilisation without spare capacity. A percentage reads as comfortable until someone works out what it leaves in bit/s.
Behavior contract (gate 3)
Service and flow validation, eligibility by latency and assurance, deterministic best-fit assignment, per-service aggregate load, the three-way flow verdict with a tolerance at the capacity and latency bounds, the separated coverage and adequacy questions, and the utilisation and spare-capacity report are exercised by the gate 3 contract test: scripts/test_e50_data_transfer_services.py against scripts/e50_data_transfer_services_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e50_data_transfer_services.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.