E50 Time Correlation

Derive the correlation between onboard time and the reference time scale under ECSS-E-ST-50C clause 5.6.14.6, which asks that the two be correlated to a stated accuracy. Remove the one-way light time first, because it biases every pair alike and no fit can recover a common bias. Then fit offset and drift by least squares, take the residual spread and the standard error of the drift, and turn the stated accuracy into a validity horizon — the interval after which the correlation must be taken again. Use when sizing a time-correlation cadence or reviewing onboard clock accuracy. Trigger: ecss, e-st-50-communications, onboard-time-correlation, onboard-clock-drift-fit, time-correlation-validity-horizon, correlation-light-time-bias, recorrelation-interval-sizing.

ashfordeOU Updated 5 repo stars
Aero Agent Skills — aerospace engineering · agentskills.io format · Apache-2.0

File contents

ashfordeou/aero-agent-skills commit 7e39a35f03

Frequently asked questions

npx get-skill add ashfordeou/e50-time-correlation