ECSS SpaceWire — CCSDS Packet Transfer (space-systems/ecss/e5053-ccsds-packet)
Use when the task is the packet of ECSS-E-ST-50-53C clause 5.1.1 — the space packet this transfer protocol carries across a SpaceWire link, and whether a constructed or captured one has fields, lengths and a frame that agree with each other.
Domain quick reference
- The packet is a six-byte primary header followed by a data field. Six fields live in that header: version, direction, a secondary-header flag, the application process identifier, the grouping flags and the sequence counter, plus the length of the data field.
- The length field is off by one on purpose. It counts one less than the data field, which is why an empty data field cannot be expressed at all and why the largest is exactly sixty-four kilobytes. Reading it as a plain byte count is the most common capture-analysis error there is.
- The transfer protocol does not change the packet. It wraps it: routing bytes at the front, then one byte that names which protocol the rest of the frame belongs to, then the packet unchanged. A frame budget therefore has three parts, not one.
- Grouping flags describe a sequence, not a packet. A datum that fits in one data field is unsegmented; one that does not becomes a first part, any number of continuation parts and a last part, and the receiver reassembles on that pattern alone.
- The sequence counter is per application identifier and it wraps. A gap in it is the evidence that a packet was lost, so a receiver that does not track it cannot tell a dropped packet from a quiet source.
- Fill traffic is carried on its own application identifier. It exists to keep a channel busy, so it is unsegmented and has nothing that a secondary header would describe.
Workflow
- Normalise the field record and refuse the inputs that are errors: a version this protocol does not carry, an identifier past its field, a grouping value past its two bits, a counter past its fourteen, a data field that is empty or larger than the length field can express.
- Pack the three header words in their bit positions, and confirm a captured header unpacks back to the same record — including being rejected when the captured version is not the one carried here.
- Convert between the data-field size and the length field in both directions rather than writing the off-by-one at each call site.
- Size the packet as header plus data field, and the frame as routing bytes plus the protocol byte plus the packet.
- Split a user datum against the largest data field the profile allows, assigning first, continuation and last flags, and confirm the parts sum back to the datum.
- Grade the packet: fill traffic that is grouped or declares a secondary header, a frame past the declared maximum, and a counter that did not advance by one from the previous packet on that identifier.
Pitfalls
- Reading the length field as the data-field size. Every derived figure is then one byte short, and a reassembly that trusts it drops the last byte of every part.
- Budgeting a link from packet sizes alone. The routing bytes and the protocol byte are on the wire too, and with short packets they are a noticeable share of it.
- Treating the grouping flags as a per-packet attribute. They only mean anything as a sequence; a lone continuation part with no first part before it is a reassembly failure, not a standalone packet.
- Tracking one sequence counter for the whole link. The counter belongs to the application identifier, and a shared counter reports gaps that are only interleaving.
- Filling a channel with idle packets that carry a secondary header or a grouping flag. Fill traffic that looks like real traffic will be reassembled as real traffic somewhere downstream.
Behavior contract (gate 3)
The field validation, primary-header packing and unpacking, length-field conversion, packet and frame sizing, user-datum grouping, sequence- counter continuity and the fill-traffic and frame-maximum grading are exercised by the gate 3 contract test: scripts/test_e5053_ccsds_packet.py against scripts/e5053_ccsds_packet_logic.py (stdlib unittest, offline). Run: python3 scripts/test_e5053_ccsds_packet.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.