ECSS Structures — Fatigue and Fracture Test (space-systems/ecss/fatigue-and-fracture-test)
Use when the task is the fatigue and fracture test of a spacecraft structural
component per ECSS-E-ST-32C clause 4.6.3.11 — constructing a load spectrum
from mission-profile blocks, accumulating Miner's rule damage, deriving the
test life from a scatter factor, selecting a crack-detection method, and
assessing specimen outcome and residual strength.
Domain quick reference
- Clause 4.6.3.11 requires that fatigue-critical components be exercised
under a realistic load spectrum and that any cracks be detectable before
they become critical. The spectrum is built from a set of stress-level
blocks, each described by a peak stress amplitude and a cycle count drawn
from the mission profile (launch, on-orbit manoeuvres, thermal cycling,
re-entry as applicable).
- Miner's rule provides the cumulative damage index D = Σ(n_i / N_i),
where n_i is the number of applied cycles at stress level i and N_i is
the number of cycles to failure at that level from the S-N curve.
Failure is predicted when D reaches 1.0. A spectrum that drives D to or
above 1.0 before the end of the required test life is a finding.
- The test life is not equal to the design life: a scatter factor (≥ 1.0)
accounts for material variability and unknown load uncertainty. Typical
values are 4.0 for metallic structures and 6.0 for fibre-reinforced
composites. The specimen must survive test_life = ceil(design_life ×
scatter_factor) cycles without triggering the failure criterion.
- Crack detection capability depends on the inspection method. Each method
has a minimum detectable crack size; a method is only acceptable for a
given inspection interval if its threshold is smaller than the critical
crack size at that interval. Common methods and indicative thresholds:
eddy current (
0.1 mm), dye penetrant (0.2 mm), magnetic particle
(0.3 mm), ultrasonic/radiographic (0.5 mm), visual (~3.0 mm).
- Residual-strength verification after the fatigue test confirms that
accumulated damage has not reduced the load-carrying capacity below
the limit load. A linear knock-down model (strength reduced
proportionally to Miner damage) is used as a conservative bound.
Workflow
- Inventory the load environment and construct the spectrum: one block
per distinct stress-level band in the mission profile, each with a
positive stress amplitude and a positive cycle count. Reject any block
with a non-positive value before it enters the damage calculation.
A single-block spectrum is permissible but warrants a review note
recommending multi-block representation for realism.
- Select or derive the S-N curve for the material and joint configuration
at each stress level in the spectrum. Every stress level in the
spectrum must have a corresponding S-N entry; a missing entry blocks
the damage calculation with an explicit error.
- Apply Miner's rule: compute D = Σ(n_i / N_i) over all blocks. If D ≥
1.0 the spectrum drives the component to failure before the end of the
applied cycles; report a finding and do not proceed to derive the test
life until the spectrum or the design is revised.
- Determine the material category (metallic or composite) and apply the
appropriate scatter factor to derive the test life. Use
test_cycles = ceil(design_life_cycles × scatter_factor). Ensure the
scatter factor is ≥ 1.0; a value below 1.0 is a configuration error.
- Select the non-destructive inspection method for crack monitoring
during the test. Confirm the method's detection threshold is below the
smallest crack size that must be caught. Record the selected method and
threshold in the test plan.
- Run the fatigue test. After the test, evaluate the specimen: it passes
if it completed at least the required test cycles and no crack was
detected before the required life (standard mode), or if it completed
the required life even with a crack (damage-tolerance demonstration
mode). Failure to reach the required cycle count, or a crack appearing
before the required life in standard mode, is a test failure.
- After the test, compute the residual strength using the accumulated
Miner damage and confirm it exceeds the limit load. A residual
strength at or below limit load is a finding that must be resolved
before the structural margin can be closed.
Pitfalls
- Applying the design-life cycle count directly as the test-life count —
the scatter factor is mandatory; omitting it unconservatively
understates the required test duration.
- Using a single S-N data point extrapolated beyond its valid stress range
— the S-N curve must cover every stress level in the spectrum; any
extrapolation outside the data range needs explicit justification.
- Treating a missing S-N entry as zero damage — a missing entry means the
damage contribution is unknown, which is a data gap, not a conservative
bound; the calculation must be blocked until the data is supplied.
- Selecting a crack-detection method whose threshold exceeds the critical
crack size at the inspection interval — the method will miss a
growing crack, leaving the component at undetected risk.
- Collapsing standard-mode and damage-tolerance-mode pass criteria — in
standard mode any crack before the required life is a failure; in
damage-tolerance mode the structure must still survive to the required
life even after a crack is detected; the two modes must not be mixed.
- Reading D < 1.0 as a safety margin without checking residual strength —
accumulated sub-critical damage still reduces load capacity; a residual-
strength check is required even when Miner's rule has not been reached.
Behavior contract (gate 3)
The spectrum-validation, Miner's-rule damage, test-life derivation,
crack-detection capability, specimen-outcome, and residual-strength logic
is exercised by the gate 3 contract test:
scripts/test_fatigue_and_fracture_test.py against
scripts/fatigue_and_fracture_test_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_fatigue_and_fracture_test.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: fatigue-and-fracture-test3description: "Use when assess fatigue life and fracture-critical behaviour of a4 spacecraft structural component under ECSS-E-ST-32C clause 4.6.3.11: define a5 representative load spectrum from mission-profile blocks at discrete stress6 levels, apply Miner's rule to accumulate cycle damage and compare against the7 failure threshold, derive the required test life using a material-appropriate8 scatter factor, select an inspection method with adequate crack-detection9 capability, evaluate each specimen against completed-cycles and crack-found10 criteria, and verify residual strength after sustained damage.11 Trigger: ecss, e-st-32-structures-scope, fatigue-test, fracture-test,12 load-spectrum, miners-rule, crack-detection, damage-tolerance, residual-strength."13license: Apache-2.014compliance: STANDARDS-REF15standards:16 - id: ecss17 reference-only: true18gated: false19domain: space-systems20pack: space-systems21compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"22metadata:23 source: https://skillmd.com/skills/ashfordeou/fatigue-and-fracture-test24 domain: space-systems25 subdomain: ecss26 tags: [ecss, e-st-32-structures-scope, fatigue-test, fracture-test, load-spectrum, miners-rule, crack-detection, damage-tolerance, residual-strength]27 version: 0.1.028 author: Aero Agent Skills29---3031# ECSS Structures — Fatigue and Fracture Test (space-systems/ecss/fatigue-and-fracture-test)3233Use when the task is the fatigue and fracture test of a spacecraft structural34component per ECSS-E-ST-32C clause 4.6.3.11 — constructing a load spectrum35from mission-profile blocks, accumulating Miner's rule damage, deriving the36test life from a scatter factor, selecting a crack-detection method, and37assessing specimen outcome and residual strength.3839## Domain quick reference4041- Clause 4.6.3.11 requires that fatigue-critical components be exercised42 under a realistic load spectrum and that any cracks be detectable before43 they become critical. The spectrum is built from a set of stress-level44 blocks, each described by a peak stress amplitude and a cycle count drawn45 from the mission profile (launch, on-orbit manoeuvres, thermal cycling,46 re-entry as applicable).47- Miner's rule provides the cumulative damage index D = Σ(n_i / N_i),48 where n_i is the number of applied cycles at stress level i and N_i is49 the number of cycles to failure at that level from the S-N curve.50 Failure is predicted when D reaches 1.0. A spectrum that drives D to or51 above 1.0 before the end of the required test life is a finding.52- The test life is not equal to the design life: a scatter factor (≥ 1.0)53 accounts for material variability and unknown load uncertainty. Typical54 values are 4.0 for metallic structures and 6.0 for fibre-reinforced55 composites. The specimen must survive test_life = ceil(design_life ×56 scatter_factor) cycles without triggering the failure criterion.57- Crack detection capability depends on the inspection method. Each method58 has a minimum detectable crack size; a method is only acceptable for a59 given inspection interval if its threshold is smaller than the critical60 crack size at that interval. Common methods and indicative thresholds:61 eddy current (~0.1 mm), dye penetrant (~0.2 mm), magnetic particle62 (~0.3 mm), ultrasonic/radiographic (~0.5 mm), visual (~3.0 mm).63- Residual-strength verification after the fatigue test confirms that64 accumulated damage has not reduced the load-carrying capacity below65 the limit load. A linear knock-down model (strength reduced66 proportionally to Miner damage) is used as a conservative bound.6768## Workflow69701. Inventory the load environment and construct the spectrum: one block71 per distinct stress-level band in the mission profile, each with a72 positive stress amplitude and a positive cycle count. Reject any block73 with a non-positive value before it enters the damage calculation.74 A single-block spectrum is permissible but warrants a review note75 recommending multi-block representation for realism.762. Select or derive the S-N curve for the material and joint configuration77 at each stress level in the spectrum. Every stress level in the78 spectrum must have a corresponding S-N entry; a missing entry blocks79 the damage calculation with an explicit error.803. Apply Miner's rule: compute D = Σ(n_i / N_i) over all blocks. If D ≥81 1.0 the spectrum drives the component to failure before the end of the82 applied cycles; report a finding and do not proceed to derive the test83 life until the spectrum or the design is revised.844. Determine the material category (metallic or composite) and apply the85 appropriate scatter factor to derive the test life. Use86 test_cycles = ceil(design_life_cycles × scatter_factor). Ensure the87 scatter factor is ≥ 1.0; a value below 1.0 is a configuration error.885. Select the non-destructive inspection method for crack monitoring89 during the test. Confirm the method's detection threshold is below the90 smallest crack size that must be caught. Record the selected method and91 threshold in the test plan.926. Run the fatigue test. After the test, evaluate the specimen: it passes93 if it completed at least the required test cycles and no crack was94 detected before the required life (standard mode), or if it completed95 the required life even with a crack (damage-tolerance demonstration96 mode). Failure to reach the required cycle count, or a crack appearing97 before the required life in standard mode, is a test failure.987. After the test, compute the residual strength using the accumulated99 Miner damage and confirm it exceeds the limit load. A residual100 strength at or below limit load is a finding that must be resolved101 before the structural margin can be closed.102103## Pitfalls104105- Applying the design-life cycle count directly as the test-life count —106 the scatter factor is mandatory; omitting it unconservatively107 understates the required test duration.108- Using a single S-N data point extrapolated beyond its valid stress range109 — the S-N curve must cover every stress level in the spectrum; any110 extrapolation outside the data range needs explicit justification.111- Treating a missing S-N entry as zero damage — a missing entry means the112 damage contribution is unknown, which is a data gap, not a conservative113 bound; the calculation must be blocked until the data is supplied.114- Selecting a crack-detection method whose threshold exceeds the critical115 crack size at the inspection interval — the method will miss a116 growing crack, leaving the component at undetected risk.117- Collapsing standard-mode and damage-tolerance-mode pass criteria — in118 standard mode any crack before the required life is a failure; in119 damage-tolerance mode the structure must still survive to the required120 life even after a crack is detected; the two modes must not be mixed.121- Reading D < 1.0 as a safety margin without checking residual strength —122 accumulated sub-critical damage still reduces load capacity; a residual-123 strength check is required even when Miner's rule has not been reached.124125## Behavior contract (gate 3)126127The spectrum-validation, Miner's-rule damage, test-life derivation,128crack-detection capability, specimen-outcome, and residual-strength logic129is exercised by the gate 3 contract test:130scripts/test_fatigue_and_fracture_test.py against131scripts/fatigue_and_fracture_test_logic.py (stdlib unittest, offline). Run:132python3 scripts/test_fatigue_and_fracture_test.py133134## Compliance135136- ECSS standards are freely downloadable (ESA); cite the source and137 paraphrase per standards-map.yaml.138- compliance: STANDARDS-REF, gated: false.