ECSS Structures — Metallic Pressure Components (space-systems/ecss/metallic-pressure-components)
Use when the task is verifying metallic pressure components under ECSS-E-ST-32
clause 4.5.1 — covering valves, pumps, pressure lines, fittings, and hoses —
by checking pressure margins against the maximum expected operating pressure,
computing hoop and von Mises stress for cylindrical sections, evaluating
strength margins of safety, and confirming fatigue safe life.
Domain quick reference
- Clause 4.5.1 covers five metallic pressure component (MPC) types: valves,
pumps, pressure lines, fittings, and hoses. Each component is categorized
into exactly one of these types before verification begins.
- Proof pressure and burst pressure requirements are applied against the
maximum expected operating pressure (MEOP). Lines and fittings use a burst
factor of 1.5 × MEOP; valves, pumps, and hoses use 2.0 × MEOP. The proof
factor is 1.1 × MEOP for all component types.
- For thin-walled cylindrical sections (radius-to-thickness ratio ≥ 10), hoop
stress is σ_h = p·r/t and axial stress is σ_a = p·r/(2t) for closed-end
geometry. The von Mises equivalent stress combines both for the
ultimate-strength margin of safety: MS = F_tu / (γ × σ_vm) − 1, where γ is
the material safety factor (default 1.25). A non-negative margin is required.
- Fatigue and safe life: the demonstrated test life (pressure cycles) is
divided by a scatter factor of 4 to obtain the safe life. The safe life must
cover the required mission pressure cycles. A component whose safe life falls
short of the required cycles must be re-tested, redesigned, or declared a
fracture-critical part and subjected to the fracture control programme.
Workflow
- Categorize each pressure component as valve, pump, line, fitting, or hose.
Reject any component with an unrecognized type before it enters the pressure
verification sequence.
- For each component, confirm the proof pressure test value satisfies
proof ≥ 1.1 × MEOP. Record the proof ratio; flag any component below the
threshold.
- Determine the applicable burst factor (1.5 for lines and fittings; 2.0 for
valves, pumps, and hoses), then confirm burst pressure ≥ factor × MEOP.
Flag any shortfall.
- For cylindrical sections, verify the thin-wall criterion (r/t ≥ 10), compute
hoop and axial stress at MEOP, derive the von Mises equivalent, and
calculate the margin of safety against the material ultimate tensile strength
with the applicable safety factor (default 1.25). A negative margin is a
structural finding.
- Retrieve the fatigue test life (pressure cycles to failure or test runout).
Divide by the scatter factor of 4 to obtain the safe life. Confirm the safe
life exceeds the required mission pressure cycles. Record the life margin
factor (safe life / required cycles).
- Aggregate findings per component: a component is verified only when no
proof, burst, strength, or fatigue finding remains open.
Pitfalls
- Applying the burst factor of 2.0 to lines and fittings — lines and fittings
carry a burst factor of 1.5 under clause 4.5.1; using 2.0 overstates the
requirement without providing additional safety margin insight.
- Using the thin-wall stress formula when r/t < 10 — the thin-wall hoop stress
equation is not valid for thick sections; use the Lamé thick-wall formula or
a finite-element model for sections below the r/t = 10 threshold.
- Conflating proof pressure with burst pressure — proof is a non-destructive
structural integrity check; burst is the pressure at which the component must
not rupture. Both must be checked independently.
- Reading a scatter factor of 4 applied to the stress amplitude rather than the
life — clause 4.5.1 applies the scatter factor to the demonstrated life in
cycles, not to the stress level. Misapplying it to stress incorrectly
overstates safe life.
- Skipping the fatigue check for low-cycle components — components that see
fewer than 1000 pressure cycles are not exempt; the scatter factor of 4 still
applies to whatever test life was demonstrated.
Behavior contract (gate 3)
The component-categorization, proof/burst pressure, hoop stress, margin of
safety, and fatigue safe-life logic is exercised by the gate 3 contract test:
scripts/test_metallic_pressure_components.py against
scripts/metallic_pressure_components_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_metallic_pressure_components.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase
per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: metallic-pressure-components3description: "Use when verify metallic pressure components — valves, pumps, pressure lines, fittings, and hoses — against ECSS-E-ST-32 clause 4.5.1: categorize each component by type, check proof and burst pressure margins against the maximum expected operating pressure using the applicable pressure factors, compute hoop stress and von Mises equivalent stress for cylindrical sections, evaluate ultimate-strength margins-of-safety, and confirm fatigue safe-life by applying a scatter factor of four to the demonstrated test life. Trigger: ecss, e-st-32-structures-scope, metallic-pressure-components, pressure-lines, valves, pumps, fittings, pressure-cycle-fatigue, safe-life."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/metallic-pressure-components15 domain: space-systems16 subdomain: ecss17 tags: [ecss, e-st-32-structures-scope, metallic-pressure-components, valves, pumps, pressure-lines, fittings, hoses, pressure-cycle-fatigue, safe-life]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Structures — Metallic Pressure Components (space-systems/ecss/metallic-pressure-components)2324Use when the task is verifying metallic pressure components under ECSS-E-ST-3225clause 4.5.1 — covering valves, pumps, pressure lines, fittings, and hoses —26by checking pressure margins against the maximum expected operating pressure,27computing hoop and von Mises stress for cylindrical sections, evaluating28strength margins of safety, and confirming fatigue safe life.2930## Domain quick reference3132- Clause 4.5.1 covers five metallic pressure component (MPC) types: valves,33 pumps, pressure lines, fittings, and hoses. Each component is categorized34 into exactly one of these types before verification begins.35- Proof pressure and burst pressure requirements are applied against the36 maximum expected operating pressure (MEOP). Lines and fittings use a burst37 factor of 1.5 × MEOP; valves, pumps, and hoses use 2.0 × MEOP. The proof38 factor is 1.1 × MEOP for all component types.39- For thin-walled cylindrical sections (radius-to-thickness ratio ≥ 10), hoop40 stress is σ_h = p·r/t and axial stress is σ_a = p·r/(2t) for closed-end41 geometry. The von Mises equivalent stress combines both for the42 ultimate-strength margin of safety: MS = F_tu / (γ × σ_vm) − 1, where γ is43 the material safety factor (default 1.25). A non-negative margin is required.44- Fatigue and safe life: the demonstrated test life (pressure cycles) is45 divided by a scatter factor of 4 to obtain the safe life. The safe life must46 cover the required mission pressure cycles. A component whose safe life falls47 short of the required cycles must be re-tested, redesigned, or declared a48 fracture-critical part and subjected to the fracture control programme.4950## Workflow51521. Categorize each pressure component as valve, pump, line, fitting, or hose.53 Reject any component with an unrecognized type before it enters the pressure54 verification sequence.552. For each component, confirm the proof pressure test value satisfies56 proof ≥ 1.1 × MEOP. Record the proof ratio; flag any component below the57 threshold.583. Determine the applicable burst factor (1.5 for lines and fittings; 2.0 for59 valves, pumps, and hoses), then confirm burst pressure ≥ factor × MEOP.60 Flag any shortfall.614. For cylindrical sections, verify the thin-wall criterion (r/t ≥ 10), compute62 hoop and axial stress at MEOP, derive the von Mises equivalent, and63 calculate the margin of safety against the material ultimate tensile strength64 with the applicable safety factor (default 1.25). A negative margin is a65 structural finding.665. Retrieve the fatigue test life (pressure cycles to failure or test runout).67 Divide by the scatter factor of 4 to obtain the safe life. Confirm the safe68 life exceeds the required mission pressure cycles. Record the life margin69 factor (safe life / required cycles).706. Aggregate findings per component: a component is verified only when no71 proof, burst, strength, or fatigue finding remains open.7273## Pitfalls7475- Applying the burst factor of 2.0 to lines and fittings — lines and fittings76 carry a burst factor of 1.5 under clause 4.5.1; using 2.0 overstates the77 requirement without providing additional safety margin insight.78- Using the thin-wall stress formula when r/t < 10 — the thin-wall hoop stress79 equation is not valid for thick sections; use the Lamé thick-wall formula or80 a finite-element model for sections below the r/t = 10 threshold.81- Conflating proof pressure with burst pressure — proof is a non-destructive82 structural integrity check; burst is the pressure at which the component must83 not rupture. Both must be checked independently.84- Reading a scatter factor of 4 applied to the stress amplitude rather than the85 life — clause 4.5.1 applies the scatter factor to the demonstrated life in86 cycles, not to the stress level. Misapplying it to stress incorrectly87 overstates safe life.88- Skipping the fatigue check for low-cycle components — components that see89 fewer than 1000 pressure cycles are not exempt; the scatter factor of 4 still90 applies to whatever test life was demonstrated.9192## Behavior contract (gate 3)9394The component-categorization, proof/burst pressure, hoop stress, margin of95safety, and fatigue safe-life logic is exercised by the gate 3 contract test:96scripts/test_metallic_pressure_components.py against97scripts/metallic_pressure_components_logic.py (stdlib unittest, offline). Run:98python3 scripts/test_metallic_pressure_components.py99100## Compliance101102- ECSS standards are freely downloadable (ESA); cite the source and paraphrase103 per standards-map.yaml.104- compliance: STANDARDS-REF, gated: false.