ECSS Harness Manufacturing — Complementary Branching of Braid-Shielded Bundles (space-systems/ecss/q2030-comp-branching)
Use when the task is the complementary branching layer of ECSS-Q-ST-20-30C clause 7.7 -- the space-specific rules for taking a branch out of a bundle that carries a metallic braid shield, and for keeping the shielding continuous through the breakout instead of ending it there.
Domain quick reference
- A braid is not a solid shield; it is a mesh whose effectiveness follows from its geometry. The pick density, the carrier count, the ends per carrier, the braid wire diameter and the diameter the braid rides on together set the braid angle, and the braid angle sets how much surface one direction of the weave fills. Optical coverage follows from that filling factor, and it is the number a coverage requirement is written against.
- The same braid behaves differently on different bundles. Laid over a smaller diameter the weave lies at a shallower angle and covers more, so a branch braid taken from the same spool as the trunk is usually better, not worse -- which is exactly why a downgrade is easy to miss when a thinner braid is substituted at the breakout.
- The coverage requirement at a breakout is therefore two-sided: the branch owes the project floor AND the coverage the trunk already had. A branch that meets the floor but falls below the trunk has silently downgraded the shield for everything downstream of the breakout.
- Continuity is a resistance budget, not a continuity beep. The path a branch presents is the trunk run plus the junction plus the branch run, and the junction is normally the dominant and the most variable term. Grading the segments separately and the total against the end-to-end limit is what makes a marginal junction visible.
- A junction that is not bonded at all is not a high-resistance finding, it is a different defect: the trunk shield stops at the breakout and the branch shield floats, which is worse than an unshielded branch because the floating braid becomes an antenna rather than a return.
- A shield that stops short of the takeoff leaves an aperture, and no coverage figure compensates for an aperture. The unshielded length is measured and limited in its own right.
Workflow
- Compute the trunk braid geometry from its construction: braid angle, filling factor and optical coverage.
- Compute the same three quantities for every branch braid, refusing a construction whose filling factor exceeds unity rather than reporting a coverage the expression no longer describes.
- Grade each branch coverage against the greater of the project floor and the trunk coverage, absorbing an exact equality with a tolerance.
- Add the trunk, junction and branch segments into one shield-continuity resistance and grade the total against the end-to-end limit.
- Refuse a branch whose junction carries no bond at all, separately from the resistance grading, so the two defects do not merge into one finding.
- Grade the unshielded length the breakout leaves against its limit.
- Where the project caps how many branches leave one point, grade the branch count too, then roll every finding into one breakout verdict carrying the worst branch coverage.
Pitfalls
- Grading a braid by its stated coverage percentage. That figure belongs to the braid laid on the diameter it was specified for; re-laid over a different bundle it is a different number, so it is recomputed from the construction and the diameter actually used.
- Holding a branch only to the coverage floor. The floor is the project minimum, not the trunk's achieved value, so a branch between the two is a downgrade that passes a floor-only check.
- Reading continuity with a two-wire beep. The junction resistance that matters sits well below what lead resistance masks, so the budget needs segment values, not a continuity indication.
- Treating an unbonded junction as a large resistance. An unbonded braid is a floating conductor, which couples rather than returns; it belongs in its own finding so it is not closed by improving a contact.
- Ignoring the unshielded length because coverage passed. Coverage describes the braid that is there; the aperture is the length where there is none, and it dominates at the frequencies the shield exists for.
- Reporting only the best branch. A breakout is as shielded as its worst branch, so the verdict carries the worst coverage, not the average.
- Failing a continuity total that lands exactly on the limit. The equality is a representation question, settled with a tolerance inside the comparison and never by moving the limit.
Behavior contract (gate 3)
The braid-angle and filling-factor computation, the optical-coverage expression and its unity refusal, the two-sided coverage grading against the trunk and the floor, the three-segment continuity budget, the unbonded junction refusal, the unshielded-takeoff grading, the branch-count cap and the rolled-up breakout verdict are exercised by the gate 3 contract test: scripts/test_q2030_comp_branching.py against scripts/q2030_comp_branching_logic.py (stdlib unittest, offline). Run: python3 scripts/test_q2030_comp_branching.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.