ECSS Hybrids — Interconnect Rebonding Limits (space-systems/ecss/q6005-wire-rebonding-rules)
Use when the task is clause 10.5.3 of ECSS-Q-ST-60-05C: putting an interconnect wire back after it has lifted, broken or been removed during permitted corrective work, and deciding whether the site it would land on can take another bond at all.
Domain quick reference
- A bond site is a consumable. Every attempt deforms the pad metallisation under it and leaves a footprint, and neither the metallisation nor the pad area recovers between attempts. The allowance is therefore a count of attempts, not of successes: a bond that lifted still spent its turn.
- The allowance is not one number for the whole unit. A chip pad is the smallest and most fragile bondable surface in the assembly and takes the fewest attempts; a substrate pad and a package post are larger, more robust, and take more. Applying the chip-pad number everywhere blocks repairable work, and applying the post number everywhere destroys chip metallisation.
- Attempts and area are two independent budgets. A large pad can run out of attempts while it still has room, and a small pad can run out of room while it still has attempts. Both have to be checked, and a refusal on either is a refusal.
- The remnant of the previous bond is not cosmetic. Bonding onto a tail, a stub or a lifted heel puts the new bond on top of loose metal instead of on the pad, and the pull strength that results describes the remnant rather than the joint.
- Stacking is a property of the surface, not of the operator. A post can take a bond over a previous footprint; a chip pad cannot, because the metallisation beneath the first footprint is already worked and the underlying die surface has no margin left.
- A mixed wire-and-pad metal pairing is a caution, not a bar. Gold onto aluminium and aluminium onto gold both form intermetallics over time, which is a reliability finding to be recorded and screened for — it does not make the rebond itself impermissible.
- The overall answer is not the worst site. One refused site blocks the corrective work as a whole, because the unit is not repaired until every interconnect on the repair list is back; reporting only the site that failed loses the ones that would have been fine.
Workflow
- Validate each bond geometry. A ball bond is described by its flattened diameter and a wedge bond by its width and length; an unmeasured bond cannot be budgeted against a pad that does not grow, so it is refused as an input error rather than assumed.
- Validate each site: pad kind, bondable dimensions, the bonds already placed, whether the remnant was removed, whether the proposed bond would sit over a previous footprint, and the wire and pad metals. An over-bonded pad validates rather than raising — it is the case being graded.
- Count attempts used against the allowance for that pad kind, and report the remainder floored at zero so an exhausted site reads as exhausted rather than as a negative.
- Sum the footprints already on the pad, add the proposed bond, and divide by the bondable area. Compare the utilisation with one under a tolerance, because a pad filled exactly by its bonds is a designed condition and a strict comparison there answers differently on different machines.
- Apply the placement rules: an unremoved remnant refuses, and a bond over a previous footprint refuses wherever the pad kind does not permit stacking.
- Attach the metal-pairing caution where the wire and pad metals differ, and grade the site as permitted, permitted-with-caution or not-permitted.
- Roll the sites up: an unapproved procedure or any refused site blocks the corrective work, cautions propagate, and every site keeps its own record so the repair traveller can be written from the result.
Pitfalls
- Counting successful bonds instead of attempts. A bond that lifted on placement consumed the site's metallisation exactly as a good one would, and a site graded on successes runs past its allowance without any counter registering it.
- Using one attempt allowance for the whole unit. Chip pads, substrate pads and posts do not have the same margin, and a single number is either too strict for the robust surfaces or too generous for the fragile ones.
- Checking the attempt count and stopping. Area is the other budget, and a small pad carrying two full-width wedges has no room for a third even though its counter still shows one attempt left.
- Comparing pad utilisation with a strict inequality. A pad filled exactly by its bonds is common, and the sum of products that should equal the pad area will not always compare that way; without a tolerance the same layout is accepted on one host and refused on another.
- Treating remnant removal as housekeeping. Until the tail is off, a rebond bonds to the tail, and the pull test that follows measures the wrong joint.
- Escalating a mixed-metal pairing to a refusal. Intermetallic growth is a screening and life question that belongs in the record, and refusing the rebond over it leaves the unit with no interconnect at all.
- Reporting only the failed site. The corrective work is one job; the sites that would have been accepted are needed to plan the rework, and the refused ones are needed to escalate it.
Behavior contract (gate 3)
The bond geometry validation, the pad attempt allowance, the accumulated footprint budget, the remnant and stacking placement rules, the metal-pairing caution and the per-site and overall disposition are exercised by the gate 3 contract test: scripts/test_q6005_wire_rebonding_rules.py against scripts/q6005_wire_rebonding_rules_logic.py (stdlib unittest, offline). Run: python3 scripts/test_q6005_wire_rebonding_rules.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.