ECSS Commercial EEE Components -- Class 3 Derating Rules (space-systems/ecss/q6013-class-3-derating-rules)
Use when the task is the stress limiting of ECSS-Q-ST-60-13C clause 6.2.2.5 at the lowest assurance class -- turning a commercial part's maker rating into the smaller envelope the build is allowed to work it in, and grading the applied electrical and thermal stresses against that envelope.
Domain quick reference
- A commercial part is rated by its maker for a commercial life in a commercial environment. The rating is never used directly: a derating factor is applied to every electrical stress and a step down to the temperature ceiling, so the part spends its life inside the envelope the datasheet draws.
- Electrical stress is kept as a ratio of applied to rated: the steady working voltage against the rated voltage, the steady working current against the rated current, and the dissipated power against the rated dissipation. Thermal stress is kept as an absolute ceiling, expressed as a step down from the rated maximum junction or hot-spot temperature.
- Each part family carries its own row, because the mechanism the derating protects against differs -- dielectric wear-out on a ceramic capacitor, electromigration on a die interconnect, contact erosion on a relay. One blanket factor across a board is not a derating rule, it is an average of unrelated mechanisms.
- The table at this class is the loosest of the three. More of the maker's rating is left available, because the class carries the lowest assurance target and pays for it with the least margin against the spread a commercial line can move by.
- What this class adds is an uplift on the input rather than a relief on the limit. A worst-case circuit analysis is often not run at this class, so an applied value declared from nominal analysis alone is uplifted by a fixed factor before it is graded. The uplift stands in for the spread the analysis would have found, and it can turn a nominal pass into a breach -- which is the point of it.
- The bounded relaxation the middle class opens is available here too: a single electrical stress may be carried past its table limit by no more than a fixed band where a derating relaxation record has been raised and approved for that stress on that part. Past the band the record buys nothing.
- The thermal ceiling takes no relaxation and no uplift relief at any class. The step down is the whole of the margin against a wear-out mechanism, so a record that moves it is moving the mechanism, not the paperwork.
- A junction temperature that was never predicted directly can still be had: the measured case temperature, the junction-to-case thermal resistance and the dissipated power give it. A result with no junction figure at all is half a result and is reported as not demonstrated rather than quietly passed.
- The useful output is not the pass or fail. It is the allowable applied value each rule leaves, the headroom against it, and which single stress is closest to its limit -- that is the one a thermal excursion or a rating change will break first.
Workflow
- Declare the part family, each applied stress with the maker rating it works against and the analysis it came from, any approved relaxation record per stress, and either a predicted junction temperature or the case temperature, thermal resistance and dissipation to derive one. Reject an uncategorized family rather than defaulting it; the row is chosen by family.
- Look up the family's voltage, current and power ratios and its junction step-down. Reject a stress kind the table does not cover.
- Uplift every applied value that came from nominal analysis alone, then turn each rating into the largest applied value the rule leaves, so the answer a designer needs is a number rather than a verdict.
- Grade each stress on its uplifted value. A stress sitting exactly on its limit is on-limit and compliant. A stress past the limit is a breach unless an approved record covers that stress and the overshoot stays inside the band.
- Resolve the junction temperature, derive it from the case where it was not predicted, and grade it against the derated ceiling with no relaxation available.
- Name the tightest margin across the graded stresses; that is where the design has the least room and where the next change will land.
- Close with one verdict, separating a clean pass from one that leans on an approved relaxation and from one left open by a junction that was never demonstrated, and carry every finding with it.
Pitfalls
- Grading a nominal applied value as if it were a worst case. The uplift is what this class substitutes for the analysis that was not run, and skipping it passes parts on numbers nobody bounded.
- Applying one blanket factor to every part on the board. The families fail by different mechanisms, so a ceramic capacitor and a digital integrated circuit do not share a voltage rule, and averaging them overstresses whichever is tighter.
- Reading the loosest table as the whole of the class difference. The uplift and the relaxation band are the other two halves, and the band only opens where a record names the stress and the part; an unrecorded overshoot is a breach at this class exactly as above.
- Letting an approved record carry a stress any distance. The band is bounded, and a record covering an overshoot past it is a waiver against a mechanism rather than a derating decision.
- Relaxing the junction ceiling. The step down is the margin, and the record that would move it is moving the wear-out life of the part.
- Passing a part on its electrical stresses alone. Every ratio can sit low while the junction runs hot, so a missing temperature that cannot be derived is an open item, not a silent pass.
- Comparing a ratio with its limit by bare arithmetic. The ratio is a quotient and the allowable is a product, so a stress built to sit exactly on its limit or on the band edge can land a few units in the last place above it; the comparison absorbs that representation error while the limit stays untouched.
Behavior contract (gate 3)
The family row validation, limit lookup, nominal-analysis uplift, allowable applied value, stress ratio, relaxation band, junction derivation from case temperature, thermal ceiling, per-stress grading, tightest-margin selection and overall verdict are exercised by the gate 3 contract test: scripts/test_q6013_class_3_derating_rules.py against scripts/q6013_class_3_derating_rules_logic.py (stdlib unittest, offline). Run: python3 scripts/test_q6013_class_3_derating_rules.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.