ECSS Outgassing Screening -- Test Conditions (space-systems/ecss/q7002-test-conditions)
Use when the task is the condition-set step of a thermal-vacuum outgassing
screening under ECSS-Q-ST-70-02C: a run sheet declares a specimen
temperature, a collector temperature, a chamber pressure and a soak duration,
and the question is whether that is the screening point, a justified
alternative, or a departure nobody wrote down.
Domain quick reference
- The screening point is a combination, not four independent numbers. Results
are comparable between laboratories because every one of them was taken at
the same combination, so moving any single member of it moves what the
result means.
- Specimen temperature, collector temperature and soak duration are held by
different control loops and each carries its own band. Grading them
together hides which loop is the one that drifted.
- Chamber pressure behaves differently from the three set points: it is a
ceiling. Any pressure at or below the limit satisfies the condition, and
only exceeding it is a departure, so a deep vacuum is never a finding.
- A departure is allowed when the application requires one, but the
justification belongs to the parameter that moved. A note covering "the
test conditions" leaves no record of which parameter was agreed, and the
approval reference is what makes the agreement findable later.
- Pump-down and stabilisation happen before the soak clock starts, and
cool-down after it stops. The time booked on the chamber has to hold all
four, or the soak is what gets shortened when the schedule tightens.
Workflow
- Read the four declared values, refusing a non-numeric or non-finite entry
and a soak duration that is not positive.
- Take the signed deviation of each set point from its reference and report
all three, so a run at the point still carries evidence that it was.
- Raise a departure for any set point outside its own band, naming the
parameter, the declared value and the deviation.
- Compare the declared pressure with the ceiling and raise a departure only
when it is above, absorbing an exact equality at the limit as
representation error.
- For every departed parameter, require its own justification entry carrying
a non-blank rationale and approval reference, and report a departure with
no entry separately from one with an incomplete entry.
- When a chamber window is booked, sum pump-down, stabilisation, soak and
cool-down, compare it with the booking, and report the headroom.
Pitfalls
- Treating the pressure like the temperatures. A pressure an order below the
ceiling is exactly right; flagging it as "off nominal" trains the operator
to ignore the pressure finding that matters.
- Accepting one blanket justification for several moved parameters. Each one
was agreed for its own reason, or it was not agreed at all.
- Reading a departure as a failure. A justified alternative condition is a
valid run; what is not valid is an alternative nobody recorded.
- Booking the soak duration as the chamber time. Pump-down and stabilisation
come out of the same window, and the soak is what ends up cut.
- Widening a band to make an edge case pass. An exact equality at the limit is
a representation question handled inside the comparison, not a reason to
move the limit.
Behavior contract (gate 3)
The signed set-point deviations, band comparisons, pressure ceiling,
per-parameter justification requirement and the chamber-window arithmetic are
exercised by the gate 3 contract test:
scripts/test_q7002_test_conditions.py against
scripts/q7002_test_conditions_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_q7002_test_conditions.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: q7002-test-conditions3description: "Validate the condition set written on an outgassing run sheet. Use when a screening run is being booked under ECSS-Q-ST-70-02C and the declared point has to be reconciled with the method: grade specimen temperature, collector temperature and soak duration against their own bands, treat chamber pressure as a ceiling that low vacuum satisfies, require a named rationale and approval reference for each parameter that departs rather than one blanket note, and add pump-down, stabilisation, soak and cool-down to see whether the booked chamber time can hold the run. Trigger: ecss, q-st-70-02c, outgassing-test-conditions, outgassing-specimen-temperature-setpoint, outgassing-collector-temperature-setpoint, outgassing-soak-duration, outgassing-chamber-pressure-ceiling, outgassing-condition-departure-justification."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/q7002-test-conditions15 domain: space-systems16 subdomain: ecss17 tags: [ecss, q-st-70-02-outgassing-scope, q7002-test-conditions, outgassing-specimen-temperature-setpoint, outgassing-collector-temperature-setpoint, outgassing-soak-duration, outgassing-chamber-pressure-ceiling, outgassing-condition-departure-justification]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Outgassing Screening -- Test Conditions (space-systems/ecss/q7002-test-conditions)2324Use when the task is the condition-set step of a thermal-vacuum outgassing25screening under ECSS-Q-ST-70-02C: a run sheet declares a specimen26temperature, a collector temperature, a chamber pressure and a soak duration,27and the question is whether that is the screening point, a justified28alternative, or a departure nobody wrote down.2930## Domain quick reference3132- The screening point is a combination, not four independent numbers. Results33 are comparable between laboratories because every one of them was taken at34 the same combination, so moving any single member of it moves what the35 result means.36- Specimen temperature, collector temperature and soak duration are held by37 different control loops and each carries its own band. Grading them38 together hides which loop is the one that drifted.39- Chamber pressure behaves differently from the three set points: it is a40 ceiling. Any pressure at or below the limit satisfies the condition, and41 only exceeding it is a departure, so a deep vacuum is never a finding.42- A departure is allowed when the application requires one, but the43 justification belongs to the parameter that moved. A note covering "the44 test conditions" leaves no record of which parameter was agreed, and the45 approval reference is what makes the agreement findable later.46- Pump-down and stabilisation happen before the soak clock starts, and47 cool-down after it stops. The time booked on the chamber has to hold all48 four, or the soak is what gets shortened when the schedule tightens.4950## Workflow51521. Read the four declared values, refusing a non-numeric or non-finite entry53 and a soak duration that is not positive.542. Take the signed deviation of each set point from its reference and report55 all three, so a run at the point still carries evidence that it was.563. Raise a departure for any set point outside its own band, naming the57 parameter, the declared value and the deviation.584. Compare the declared pressure with the ceiling and raise a departure only59 when it is above, absorbing an exact equality at the limit as60 representation error.615. For every departed parameter, require its own justification entry carrying62 a non-blank rationale and approval reference, and report a departure with63 no entry separately from one with an incomplete entry.646. When a chamber window is booked, sum pump-down, stabilisation, soak and65 cool-down, compare it with the booking, and report the headroom.6667## Pitfalls6869- Treating the pressure like the temperatures. A pressure an order below the70 ceiling is exactly right; flagging it as "off nominal" trains the operator71 to ignore the pressure finding that matters.72- Accepting one blanket justification for several moved parameters. Each one73 was agreed for its own reason, or it was not agreed at all.74- Reading a departure as a failure. A justified alternative condition is a75 valid run; what is not valid is an alternative nobody recorded.76- Booking the soak duration as the chamber time. Pump-down and stabilisation77 come out of the same window, and the soak is what ends up cut.78- Widening a band to make an edge case pass. An exact equality at the limit is79 a representation question handled inside the comparison, not a reason to80 move the limit.8182## Behavior contract (gate 3)8384The signed set-point deviations, band comparisons, pressure ceiling,85per-parameter justification requirement and the chamber-window arithmetic are86exercised by the gate 3 contract test:87scripts/test_q7002_test_conditions.py against88scripts/q7002_test_conditions_logic.py (stdlib unittest, offline). Run:89python3 scripts/test_q7002_test_conditions.py9091## Compliance9293- ECSS standards are freely downloadable (ESA); cite the source and94 paraphrase per standards-map.yaml.95- compliance: STANDARDS-REF, gated: false.