ECSS Particle and UV Radiation Testing — In-Situ versus Ex-Situ Measurement (space-systems/ecss/q7006-in-situ-vs-ex-situ)
Use when the task is choosing, for each property of an ECSS-Q-ST-70-06C
particle or UV exposure, whether it is measured inside the chamber
without breaking vacuum or afterwards on a bench instrument — and what
handling the second choice obliges.
Domain quick reference
- The choice is not about convenience. Radiation-induced darkening in
glasses, white paints and polymers bleaches once the specimen is warm,
lit and in air, so an ex-situ number can be a partly recovered number
wearing the label of an irradiated one.
- Recovery is described by a half-time. The fraction already back when
the instrument sees the specimen follows from the transfer time and
that half-time alone, and it is the quantity the decision turns on —
not the transfer time in isolation, which means nothing without the
half-time beside it.
- Inverting that relation gives the transfer-time ceiling: the longest
handling that still keeps the recovered fraction under its limit. It
is a derived number, so it moves with the material and is not a house
constant to be copied between campaigns.
- Air, moisture and light are separate drivers from recovery. An oxidising
surface, a hygroscopic coating and a photo-bleaching glass each force
their own control, and a specimen brought back to air more often than
the handling ceiling allows accumulates all of them.
- An in-situ requirement the facility cannot meet is still a requirement.
Recording it as a finding keeps it visible in the report; silently
reading the property out ex-situ makes the shortfall disappear.
Workflow
- Normalize each property record: recovery half-time where the property
recovers, the air, moisture and light sensitivities, whether an
in-situ instrument exists, and the planned transfer time, atmosphere,
humidity and number of chamber openings.
- Convert the transfer time and the half-time into the recovered
fraction and compare it with its ceiling.
- Add the handling drivers: an air-sensitive surface carried through
air, a moisture-sensitive surface above the humidity ceiling, more
chamber openings than the handling ceiling allows.
- Any driver that fires makes the read-out in-situ. Where no in-situ
instrument exists, keep the ex-situ mode and raise the shortfall.
- For every ex-situ read-out, derive the controls it has to carry and
the transfer-time ceiling it has to respect.
- Compare the mandated controls with the controls the plan actually
lists, and report any that were never planned.
- Emit the per-property decisions, the two mode lists, the required
controls and every finding; the allocation is sound only when no
finding stands.
Pitfalls
- Copying a transfer-time ceiling from an earlier campaign. It is a
function of the material's half-time and changes with the material.
- Reading the recovered fraction as small because the transfer was
"quick". Two hours is nothing against a ten-day half-time and most of
the change against a one-hour one.
- Treating a nitrogen-purged glovebag as covering photo-bleaching. It
keeps air out and lets light in; they are different controls.
- Counting only the final chamber opening. Every intermediate read-out
that brings the specimen back to air is another exposure to handling.
- Dropping the in-situ requirement because the facility has no in-vacuum
instrument. The requirement is a property of the material; only the
shortfall belongs to the facility.
Behavior contract (gate 3)
The record validation, recovery arithmetic, transfer-time ceiling,
in-situ drivers, handling-control derivation, per-property decision and
allocation aggregation are exercised by the gate 3 contract test:
scripts/test_q7006_in_situ_vs_ex_situ.py against
scripts/q7006_in_situ_vs_ex_situ_logic.py (stdlib unittest, offline). Run:
python3 scripts/test_q7006_in_situ_vs_ex_situ.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: q7006-in-situ-vs-ex-situ3description: "Determine whether each property of a particle or UV irradiation is read out without breaking vacuum or after transfer, under ECSS-Q-ST-70-06C. Use when a bleaching or air-sensitive property must be measured and the handling between chamber and instrument can undo what the beam did. Converts the transfer time and the recovery half-time into the fraction that has already come back, forces an in-situ read-out once that fraction passes its ceiling or the surface meets air, humidity or repeated openings, derives the transfer-time ceiling, and mandates the sealed, dry, light-tight handling an ex-situ read-out has to carry. Trigger: ecss, q-st-70-06, in-situ-versus-ex-situ-read-out, radiation-induced-darkening-recovery, transfer-time-ceiling, specimen-handling-controls, air-sensitive-specimen-transfer, chamber-opening-count."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/q7006-in-situ-vs-ex-situ15 domain: space-systems16 subdomain: ecss17 tags: [ecss, q-st-70-06-particle-uv-radiation-testing-scope, q7006-in-situ-vs-ex-situ, in-situ-versus-ex-situ-read-out, radiation-induced-darkening-recovery, transfer-time-ceiling, radiation-specimen-handling-controls, chamber-opening-count]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Particle and UV Radiation Testing — In-Situ versus Ex-Situ Measurement (space-systems/ecss/q7006-in-situ-vs-ex-situ)2324Use when the task is choosing, for each property of an ECSS-Q-ST-70-06C25particle or UV exposure, whether it is measured inside the chamber26without breaking vacuum or afterwards on a bench instrument — and what27handling the second choice obliges.2829## Domain quick reference3031- The choice is not about convenience. Radiation-induced darkening in32 glasses, white paints and polymers bleaches once the specimen is warm,33 lit and in air, so an ex-situ number can be a partly recovered number34 wearing the label of an irradiated one.35- Recovery is described by a half-time. The fraction already back when36 the instrument sees the specimen follows from the transfer time and37 that half-time alone, and it is the quantity the decision turns on —38 not the transfer time in isolation, which means nothing without the39 half-time beside it.40- Inverting that relation gives the transfer-time ceiling: the longest41 handling that still keeps the recovered fraction under its limit. It42 is a derived number, so it moves with the material and is not a house43 constant to be copied between campaigns.44- Air, moisture and light are separate drivers from recovery. An oxidising45 surface, a hygroscopic coating and a photo-bleaching glass each force46 their own control, and a specimen brought back to air more often than47 the handling ceiling allows accumulates all of them.48- An in-situ requirement the facility cannot meet is still a requirement.49 Recording it as a finding keeps it visible in the report; silently50 reading the property out ex-situ makes the shortfall disappear.5152## Workflow53541. Normalize each property record: recovery half-time where the property55 recovers, the air, moisture and light sensitivities, whether an56 in-situ instrument exists, and the planned transfer time, atmosphere,57 humidity and number of chamber openings.582. Convert the transfer time and the half-time into the recovered59 fraction and compare it with its ceiling.603. Add the handling drivers: an air-sensitive surface carried through61 air, a moisture-sensitive surface above the humidity ceiling, more62 chamber openings than the handling ceiling allows.634. Any driver that fires makes the read-out in-situ. Where no in-situ64 instrument exists, keep the ex-situ mode and raise the shortfall.655. For every ex-situ read-out, derive the controls it has to carry and66 the transfer-time ceiling it has to respect.676. Compare the mandated controls with the controls the plan actually68 lists, and report any that were never planned.697. Emit the per-property decisions, the two mode lists, the required70 controls and every finding; the allocation is sound only when no71 finding stands.7273## Pitfalls7475- Copying a transfer-time ceiling from an earlier campaign. It is a76 function of the material's half-time and changes with the material.77- Reading the recovered fraction as small because the transfer was78 "quick". Two hours is nothing against a ten-day half-time and most of79 the change against a one-hour one.80- Treating a nitrogen-purged glovebag as covering photo-bleaching. It81 keeps air out and lets light in; they are different controls.82- Counting only the final chamber opening. Every intermediate read-out83 that brings the specimen back to air is another exposure to handling.84- Dropping the in-situ requirement because the facility has no in-vacuum85 instrument. The requirement is a property of the material; only the86 shortfall belongs to the facility.8788## Behavior contract (gate 3)8990The record validation, recovery arithmetic, transfer-time ceiling,91in-situ drivers, handling-control derivation, per-property decision and92allocation aggregation are exercised by the gate 3 contract test:93scripts/test_q7006_in_situ_vs_ex_situ.py against94scripts/q7006_in_situ_vs_ex_situ_logic.py (stdlib unittest, offline). Run:95python3 scripts/test_q7006_in_situ_vs_ex_situ.py9697## Compliance9899- ECSS standards are freely downloadable (ESA); cite the source and100 paraphrase per standards-map.yaml.101- compliance: STANDARDS-REF, gated: false.