ECSS Crimping — Terminal Placement (space-systems/ecss/q7026-terminal-placement)
Use when the Preparation clause of ECSS-Q-ST-70-26 is the task at the
moment the contact goes on the wire: deciding whether the terminal is
positioned correctly, before the tool is closed and while every finding
is still a reposition rather than a remake.
Domain quick reference
- Placement is the last free decision. Once the die closes, each of
these findings costs the contact and the wire length, so the grading
is deliberately done before the cycle and not after it.
- The insulation gap is two-sided for two different reasons. Too small
and insulation is driven under the conductor grip, where it sits
between the barrel wall and the strands and no cold weld forms
through it. Too large and bare conductor is exposed between the two
grips, supported by neither and free to flex.
- Bottoming is not the same question as gap. A conductor can sit at the
correct gap and still be short of the back of the bore, because the
strands compressed or the bundle caught on the barrel mouth.
- Bottoming has two different failures that need different answers. A
conductor pushed in short can be pushed further; a conductor whose
exposed length is shorter than the bore can never reach the back, and
that end goes back to preparation instead of being nudged.
- The inspection window exists to make bottoming visible. On contacts
that have one, a part-filled window is often the only observable
warning that the bundle did not go all the way in, because the
insertion measurement is taken outside the contact.
- A strand outside the barrel is two problems. It is conductor removed
from the joint, and it is a loose piece of metal inside a sealed
assembly.
- The two grips have different jobs. The conductor grip makes the
electrical joint and the insulation grip takes the bending load off
the strands, so insulation under the first and bare conductor under
the second are both misplacements even when the dimensions pass.
- Squareness in the nest propagates. A contact that sits off axis is
crimped off axis, and the resulting crimp height is measured across a
section the die never intended.
Workflow
- Validate the contact table: a two-sided gap band, a positive bore
depth with a bottoming tolerance that stays inside it, a window fill
requirement, a strand count and a stray allowance below it, and a
seating error limit.
- Take the entry for the contact part in hand, refusing a part number
the table does not carry rather than borrowing a neighbour's band.
- Grade the insulation gap against the band and report which side it
fell on and where inside the band it sits.
- Grade bottoming against the bore depth less its tolerance, and split
the shortfall into the reposition case and the back-to-preparation
case on the exposed conductor length. Refuse an insertion depth
larger than the conductor that was exposed.
- Read the inspection window where the contact has one, and say so
explicitly where it does not, so a reviewer knows the bottoming
evidence rests on the insertion measurement alone.
- Balance the strand bookkeeping: strands in the barrel plus strands
outside it must account for the strand count the contact expects.
- Check both grips and the seating angle, then take the worst of the
six checks, name every check at that level, and roll the batch up
with an explicit ready-to-crimp flag that also fails on unrecorded
placements.
Pitfalls
- Grading the insulation gap as a maximum only. A gap driven to zero is
the more common defect and it is the one that hides insulation inside
the crimp where nothing downstream can see it.
- Treating gap and bottoming as the same measurement. They are taken at
opposite ends of the barrel and a wire can pass one while failing the
other.
- Nudging a conductor that cannot reach the back of the bore. Pushing
harder on an end that is simply too short deforms the strands and
leaves the same shortfall.
- Skipping the inspection window because the insertion depth was
measured. The measurement is taken outside the contact and cannot see
a bundle that caught on the barrel mouth.
- Letting a strand outside the barrel pass because the joint will still
carry the current. The loose strand is a contamination and shorting
question independent of the conductor cross-section.
- Reading insulation under the conductor grip as extra strain relief.
It is an insulator inside the electrical joint.
- Accepting an off-axis contact because the crimp height will be
measured afterwards. The height is then measured across a section the
die geometry never defined.
- Reporting a batch ready to crimp without counting the placements that
were never recorded. An unrecorded placement is not an accepted one.
- Comparing a gap, an insertion depth or a seating angle with its limit
by bare arithmetic. A value specified to land exactly on the limit can
evaluate a few units in the last place past it after a unit
conversion, so the comparison absorbs that representation error while
the limit stays untouched.
Behavior contract (gate 3)
The contact table validation and its refusal of an untabulated part, the
two-sided insulation gap grading, the bottoming split between reposition
and back-to-preparation, the inspection window reading including the
no-window case, the strand bookkeeping and stray allowance, the two grip
checks, the nest seating grade, the per-placement worst disposition and
the batch rollup with its ready-to-crimp flag are exercised by the gate 3
contract test: scripts/test_q7026_terminal_placement.py against
scripts/q7026_terminal_placement_logic.py (stdlib unittest, offline).
Run:
python3 scripts/test_q7026_terminal_placement.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and
paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.
1---2name: q7026-terminal-placement3description: "Assess where a contact or terminal sits on a prepared conductor before the die closes. Use when a wire has been inserted into a barrel and the seating has to be graded while it can still be changed for free: measure the insulation-to-barrel gap against the band for that contact, confirm the conductor bottomed in the bore, read the inspection window fill, count strands left outside the barrel, check that insulation and conductor are each under their own grip, and grade how square the contact sits in the nest. Trigger: ecss, q-st-70-26-crimping, crimp-insulation-gap-band, crimp-conductor-bottoming-check, crimp-inspection-window-fill, crimp-strands-outside-barrel, crimp-contact-die-nest-seating."4license: Apache-2.05compliance: STANDARDS-REF6standards:7 - id: ecss8 reference-only: true9gated: false10domain: space-systems11pack: space-systems12compatibility: "agentskills.io SKILL.md; any SKILL.md host (Claude Code, Hermes, OpenClaw)"13metadata:14 source: https://skillmd.com/skills/ashfordeou/q7026-terminal-placement15 domain: space-systems16 subdomain: ecss17 tags: [ecss, q-st-70-26-crimping, q7026-terminal-placement, crimp-insulation-gap-band, crimp-conductor-bottoming-check, crimp-inspection-window-fill, crimp-strands-outside-barrel, crimp-contact-die-nest-seating]18 version: 0.1.019 author: Aero Agent Skills20---2122# ECSS Crimping — Terminal Placement (space-systems/ecss/q7026-terminal-placement)2324Use when the Preparation clause of ECSS-Q-ST-70-26 is the task at the25moment the contact goes on the wire: deciding whether the terminal is26positioned correctly, before the tool is closed and while every finding27is still a reposition rather than a remake.2829## Domain quick reference3031- Placement is the last free decision. Once the die closes, each of32 these findings costs the contact and the wire length, so the grading33 is deliberately done before the cycle and not after it.34- The insulation gap is two-sided for two different reasons. Too small35 and insulation is driven under the conductor grip, where it sits36 between the barrel wall and the strands and no cold weld forms37 through it. Too large and bare conductor is exposed between the two38 grips, supported by neither and free to flex.39- Bottoming is not the same question as gap. A conductor can sit at the40 correct gap and still be short of the back of the bore, because the41 strands compressed or the bundle caught on the barrel mouth.42- Bottoming has two different failures that need different answers. A43 conductor pushed in short can be pushed further; a conductor whose44 exposed length is shorter than the bore can never reach the back, and45 that end goes back to preparation instead of being nudged.46- The inspection window exists to make bottoming visible. On contacts47 that have one, a part-filled window is often the only observable48 warning that the bundle did not go all the way in, because the49 insertion measurement is taken outside the contact.50- A strand outside the barrel is two problems. It is conductor removed51 from the joint, and it is a loose piece of metal inside a sealed52 assembly.53- The two grips have different jobs. The conductor grip makes the54 electrical joint and the insulation grip takes the bending load off55 the strands, so insulation under the first and bare conductor under56 the second are both misplacements even when the dimensions pass.57- Squareness in the nest propagates. A contact that sits off axis is58 crimped off axis, and the resulting crimp height is measured across a59 section the die never intended.6061## Workflow62631. Validate the contact table: a two-sided gap band, a positive bore64 depth with a bottoming tolerance that stays inside it, a window fill65 requirement, a strand count and a stray allowance below it, and a66 seating error limit.672. Take the entry for the contact part in hand, refusing a part number68 the table does not carry rather than borrowing a neighbour's band.693. Grade the insulation gap against the band and report which side it70 fell on and where inside the band it sits.714. Grade bottoming against the bore depth less its tolerance, and split72 the shortfall into the reposition case and the back-to-preparation73 case on the exposed conductor length. Refuse an insertion depth74 larger than the conductor that was exposed.755. Read the inspection window where the contact has one, and say so76 explicitly where it does not, so a reviewer knows the bottoming77 evidence rests on the insertion measurement alone.786. Balance the strand bookkeeping: strands in the barrel plus strands79 outside it must account for the strand count the contact expects.807. Check both grips and the seating angle, then take the worst of the81 six checks, name every check at that level, and roll the batch up82 with an explicit ready-to-crimp flag that also fails on unrecorded83 placements.8485## Pitfalls8687- Grading the insulation gap as a maximum only. A gap driven to zero is88 the more common defect and it is the one that hides insulation inside89 the crimp where nothing downstream can see it.90- Treating gap and bottoming as the same measurement. They are taken at91 opposite ends of the barrel and a wire can pass one while failing the92 other.93- Nudging a conductor that cannot reach the back of the bore. Pushing94 harder on an end that is simply too short deforms the strands and95 leaves the same shortfall.96- Skipping the inspection window because the insertion depth was97 measured. The measurement is taken outside the contact and cannot see98 a bundle that caught on the barrel mouth.99- Letting a strand outside the barrel pass because the joint will still100 carry the current. The loose strand is a contamination and shorting101 question independent of the conductor cross-section.102- Reading insulation under the conductor grip as extra strain relief.103 It is an insulator inside the electrical joint.104- Accepting an off-axis contact because the crimp height will be105 measured afterwards. The height is then measured across a section the106 die geometry never defined.107- Reporting a batch ready to crimp without counting the placements that108 were never recorded. An unrecorded placement is not an accepted one.109- Comparing a gap, an insertion depth or a seating angle with its limit110 by bare arithmetic. A value specified to land exactly on the limit can111 evaluate a few units in the last place past it after a unit112 conversion, so the comparison absorbs that representation error while113 the limit stays untouched.114115## Behavior contract (gate 3)116117The contact table validation and its refusal of an untabulated part, the118two-sided insulation gap grading, the bottoming split between reposition119and back-to-preparation, the inspection window reading including the120no-window case, the strand bookkeeping and stray allowance, the two grip121checks, the nest seating grade, the per-placement worst disposition and122the batch rollup with its ready-to-crimp flag are exercised by the gate 3123contract test: scripts/test_q7026_terminal_placement.py against124scripts/q7026_terminal_placement_logic.py (stdlib unittest, offline).125Run:126python3 scripts/test_q7026_terminal_placement.py127128## Compliance129130- ECSS standards are freely downloadable (ESA); cite the source and131 paraphrase per standards-map.yaml.132- compliance: STANDARDS-REF, gated: false.