ECSS Additive Manufacturing — Build Records (space-systems/ecss/q7080-am-records)
Use when the task is the records step of ECSS-Q-ST-70-80C -- closing out a build so that the parameters, the powder history, the results and the people behind them can still be retrieved long after the machine has been re-tooled and the operator has moved on.
Domain quick reference
- A build record is the only surviving evidence that a part was made the way the qualification says it was made. It answers four questions: what was run, what it was made of, what came out, and who says so. A record that answers three of the four closes nothing.
- The two failure modes are different and are treated differently. A field nobody filled in leaves an open record. A field filled in with nothing leaves a record that looks closed and is not. Neither is a pass, and an empty field is not a zero.
- Powder is not a single input. A load is a blend of contributions, each with its own lot identity, its own mass and its own count of builds already been through. The number the class limits is a mass share of virgin powder and a highest reuse generation, and both come out of the blend arithmetic rather than off the drum.
- The highest generation in a blend and the mass-weighted mean generation say different things. A small mass of heavily reused powder barely moves the mean and can still breach the limit, which is why the highest is carried separately.
- A reference is only traceability if it resolves. A record pointing at an inspection report, a coupon set and a post-process run that no retrievable document answers is a record of intent.
- Retention is part of the record, not an afterthought. The class sets how long the evidence is held, and a record cannot be disposed of on the grounds that the parts flew.
Workflow
- Declare the part class. The field list, the powder limits and the retention period all follow from it, so an uncategorized part is rejected rather than defaulted.
- Sort every required field into present, blank or missing, and report blank and missing separately with the field named. Score the completeness on fields that actually carry a value.
- Work the powder contributions into a total mass, a virgin mass share, a mass-weighted mean reuse generation and the highest generation present. Reject a blend that lists one lot twice, or a contribution with no lot identity.
- Hold the virgin share and the highest generation against the class limits and name the breach rather than the fact of a breach.
- Resolve every inspection, coupon, post-process and non-conformance reference against the document index, and list each one that answers to nothing.
- Report retention alongside a verdict: complete and traceable, incomplete with the holes named, or complete but standing on a material history the class does not allow.
Pitfalls
- Recording the powder specification instead of the lot. The specification says what was ordered; the lot says what was loaded, and the reuse history belongs to the lot alone.
- Treating a blank field as a benign default. It is read downstream as a value that was checked and found unremarkable, when nothing was checked at all, and it is the field most likely to be blank on the build that later matters.
- Quoting a mean reuse generation as the reuse state of the load. A few kilogrammes of heavily reused powder can sit under a comfortable mean and still be the material that built the part.
- Filing a reference without filing the document. The record then passes every completeness check and fails the first time somebody tries to retrieve the evidence, which is usually during an investigation.
- Closing a record on the operator alone where the class also owes an approver. The two are different roles and the record carries both, or it carries no independent confirmation that the build was reviewed.
- Disposing of a record on part delivery. Retention runs from the record, in years the class sets, and it outlives the hardware programme more often than not.
Behavior contract (gate 3)
The field status sorting, completeness score, powder blend arithmetic, blend limits, reference resolution, retention and the records verdict are exercised by the gate 3 contract test: scripts/test_q7080_am_records.py against scripts/q7080_am_records_logic.py (stdlib unittest, offline). Run: python3 scripts/test_q7080_am_records.py
Compliance
- ECSS standards are freely downloadable (ESA); cite the source and paraphrase per standards-map.yaml.
- compliance: STANDARDS-REF, gated: false.