1---2name: quality-manager-qms-iso134853description: ISO 13485 Quality Management System implementation and maintenance for medical device organizations. Provides QMS design, documentation control, internal auditing, CAPA management, and certification support. Use when working with medical device quality systems, preparing for ISO 13485 audits, managing regulatory compliance documentation, setting up corrective actions, or building audit preparation programs. Useful for quality management, audit preparation, regulatory compliance, medical device documentation, and corrective action workflows.4triggers:5 - ISO 134856 - QMS implementation7 - quality management system8 - document control9 - internal audit10 - management review11 - quality manual12 - CAPA process13 - process validation14 - design control15 - supplier qualification16 - quality records17metadata:18 source: https://skillmd.com/skills/bestagentkits/quality-manager-qms-iso1348519---2021# Quality Manager - QMS ISO 13485 Specialist2223ISO 13485:2016 Quality Management System implementation, maintenance, and certification support for medical device organizations.2425---2627## Table of Contents2829- [QMS Implementation Workflow](#qms-implementation-workflow)30- [Document Control Workflow](#document-control-workflow)31- [Internal Audit Workflow](#internal-audit-workflow)32- [Process Validation Workflow](#process-validation-workflow)33- [Supplier Qualification Workflow](#supplier-qualification-workflow)34- [QMS Process Reference](#qms-process-reference)35- [Decision Frameworks](#decision-frameworks)36- [Tools and References](#tools-and-references)3738---3940## QMS Implementation Workflow4142Implement ISO 13485:2016 compliant quality management system from gap analysis through certification.4344### Workflow: Initial QMS Implementation45461. Conduct gap analysis against ISO 13485:2016 requirements472. Document current state vs. required state for each clause483. Prioritize gaps by:49 - Regulatory criticality50 - Risk to product safety51 - Resource requirements524. Develop implementation roadmap with milestones535. Establish Quality Manual per Clause 4.2.2:54 - QMS scope with justified exclusions55 - Process interactions56 - Procedure references576. Create required documented procedures — see [Mandatory Documented Procedures](#quick-reference-mandatory-documented-procedures) for the full list587. Deploy processes with training598. **Validation:** Gap analysis complete; Quality Manual approved; all required procedures documented and trained6061> Use the Gap Analysis Matrix template in [qms-process-templates.md](references/qms-process-templates.md) to document clause-by-clause current state, gaps, priority, and actions.6263### QMS Structure6465| Level | Document Type | Example |66|-------|---------------|---------|67| 1 | Quality Manual | QM-001 |68| 2 | Procedures | SOP-02-001 |69| 3 | Work Instructions | WI-06-012 |70| 4 | Records | Training records |7172---7374## Document Control Workflow7576Establish and maintain document control per ISO 13485 Clause 4.2.3.7778### Workflow: Document Creation and Approval79801. Identify need for new document or revision812. Assign document number per numbering convention:82 - Format: `[TYPE]-[AREA]-[SEQUENCE]-[REV]`83 - Example: `SOP-02-001-01`843. Draft document using approved template854. Route for review to subject matter experts865. Collect and address review comments876. Obtain required approvals based on document type887. Update Document Master List898. **Validation:** Document numbered correctly; all reviewers signed; Master List updated9091### Document Numbering Convention9293| Prefix | Document Type | Approval Authority |94|--------|---------------|-------------------|95| QM | Quality Manual | Management Rep + CEO |96| POL | Policy | Department Head + QA |97| SOP | Procedure | Process Owner + QA |98| WI | Work Instruction | Supervisor + QA |99| TF | Template/Form | Process Owner |100| SPEC | Specification | Engineering + QA |101102### Area Codes103104| Code | Area | Examples |105|------|------|----------|106| 01 | Quality Management | Quality Manual, policy |107| 02 | Document Control | This procedure |108| 03 | Training | Competency procedures |109| 04 | Design | Design control |110| 05 | Purchasing | Supplier management |111| 06 | Production | Manufacturing |112| 07 | Quality Control | Inspection, testing |113| 08 | CAPA | Corrective actions |114115### Document Change Control116117| Change Type | Approval Level | Examples |118|-------------|----------------|----------|119| Administrative | Document Control | Typos, formatting |120| Minor | Process Owner + QA | Clarifications |121| Major | Full review cycle | Process changes |122| Emergency | Expedited + retrospective | Safety issues |123124### Document Review Schedule125126| Document Type | Review Period | Trigger for Unscheduled Review |127|---------------|---------------|-------------------------------|128| Quality Manual | Annual | Organizational change |129| Procedures | Annual | Audit finding, regulation change |130| Work Instructions | 2 years | Process change |131| Forms | 2 years | User feedback |132133---134135## Internal Audit Workflow136137Plan and execute internal audits per ISO 13485 Clause 8.2.4.138139### Workflow: Annual Audit Program1401411. Identify processes and areas requiring audit coverage1422. Assess risk factors for audit frequency:143 - Previous audit findings144 - Regulatory changes145 - Process changes146 - Complaint trends1473. Assign qualified auditors (independent of area audited)1484. Develop annual audit schedule1495. Obtain management approval1506. Communicate schedule to process owners1517. Track completion and reschedule as needed1528. **Validation:** All processes covered; auditors qualified and independent; schedule approved153154> Use the Audit Program Template in [qms-process-templates.md](references/qms-process-templates.md) to schedule audits by clause and quarter across processes such as Document Control (4.2.3/4.2.4), Management Review (5.6), Design Control (7.3), Production (7.5), and CAPA (8.5.2/8.5.3).155156### Workflow: Individual Audit Execution1571581. Prepare audit plan with scope, criteria, and schedule1592. Notify auditee minimum 1 week prior1603. Review procedures and previous audit results1614. Prepare audit checklist1625. Conduct opening meeting1636. Collect evidence through:164 - Document review165 - Record sampling166 - Process observation167 - Personnel interviews1687. Classify findings:169 - Major NC: Absence or breakdown of system170 - Minor NC: Single lapse or deviation171 - Observation: Risk of future NC1728. Conduct closing meeting1739. Issue audit report within 5 business days17410. **Validation:** All checklist items addressed; findings supported by evidence; report distributed175176### Auditor Qualification Requirements177178| Criterion | Requirement |179|-----------|-------------|180| Training | ISO 13485 awareness + auditor training |181| Experience | Minimum 1 audit as observer |182| Independence | Not auditing own work area |183| Competence | Understanding of audited process |184185### Finding Classification Guide186187| Classification | Criteria | Response Time |188|----------------|----------|---------------|189| Major NC | System absence, total breakdown, regulatory violation | 30 days for CAPA |190| Minor NC | Single instance, partial compliance | 60 days for CAPA |191| Observation | Potential risk, improvement opportunity | Track in next audit |192193---194195## Process Validation Workflow196197Validate special processes per ISO 13485 Clause 7.5.6.198199### Workflow: Process Validation Protocol2002011. Identify processes requiring validation:202 - Output cannot be verified by inspection203 - Deficiencies appear only in use204 - Sterilization, welding, sealing, software2052. Form validation team with subject matter experts2063. Write validation protocol including:207 - Process description and parameters208 - Equipment and materials209 - Acceptance criteria210 - Statistical approach2114. Execute IQ: verify equipment installed correctly and document specifications2125. Execute OQ: test parameter ranges and verify process control2136. Execute PQ: run production conditions and verify output meets requirements2147. Write validation report with conclusions2158. **Validation:** IQ/OQ/PQ complete; acceptance criteria met; validation report approved216217### Validation Documentation Requirements218219| Phase | Content | Evidence |220|-------|---------|----------|221| Protocol | Objectives, methods, criteria | Approved protocol |222| IQ | Equipment verification | Installation records |223| OQ | Parameter verification | Test results |224| PQ | Performance verification | Production data |225| Report | Summary, conclusions | Approval signatures |226227### Revalidation Triggers228229| Trigger | Action Required |230|---------|-----------------|231| Equipment change | Assess impact, revalidate affected phases |232| Parameter change | OQ and PQ minimum |233| Material change | Assess impact, PQ minimum |234| Process failure | Full revalidation |235| Periodic | Per validation schedule (typically 3 years) |236237### Special Process Examples238239| Process | Validation Standard | Critical Parameters |240|---------|--------------------|--------------------|241| EO Sterilization | ISO 11135 | Temperature, humidity, EO concentration, time |242| Steam Sterilization | ISO 17665 | Temperature, pressure, time |243| Radiation Sterilization | ISO 11137 | Dose, dose uniformity |244| Sealing | Internal | Temperature, pressure, dwell time |245| Welding | ISO 11607 | Heat, pressure, speed |246247---248249## Supplier Qualification Workflow250251Evaluate and approve suppliers per ISO 13485 Clause 7.4.252253### Workflow: New Supplier Qualification2542551. Identify supplier category:256 - Category A: Critical (affects safety/performance)257 - Category B: Major (affects quality)258 - Category C: Minor (indirect impact)2592. Request supplier information:260 - Quality certifications261 - Product specifications262 - Quality history2633. Evaluate supplier based on:264 - Quality system (ISO certification)265 - Technical capability266 - Quality history267 - Financial stability2684. For Category A suppliers:269 - Conduct on-site audit270 - Require quality agreement2715. Calculate qualification score2726. Make approval decision:273 - >80: Approved274 - 60-80: Conditional approval275 - <60: Not approved2767. Add to Approved Supplier List2778. **Validation:** Evaluation criteria scored; qualification records complete; supplier categorized278279### Supplier Evaluation Criteria280281| Criterion | Weight | Scoring |282|-----------|--------|---------|283| Quality System | 30% | ISO 13485=30, ISO 9001=20, Documented=10, None=0 |284| Quality History | 25% | Reject rate: <1%=25, 1-3%=15, >3%=0 |285| Delivery | 20% | On-time: >95%=20, 90-95%=10, <90%=0 |286| Technical Capability | 15% | Exceeds=15, Meets=10, Marginal=5 |287| Financial Stability | 10% | Strong=10, Adequate=5, Questionable=0 |288289### Supplier Category Requirements290291| Category | Qualification | Monitoring | Agreement |292|----------|---------------|------------|-----------|293| A - Critical | On-site audit | Annual review | Quality agreement |294| B - Major | Questionnaire | Semi-annual review | Quality requirements |295| C - Minor | Assessment | Issue-based | Standard terms |296297### Supplier Performance Metrics298299| Metric | Target | Calculation |300|--------|--------|-------------|301| Accept Rate | >98% | (Accepted lots / Total lots) × 100 |302| On-Time Delivery | >95% | (On-time / Total orders) × 100 |303| Response Time | <5 days | Average days to resolve issues |304| Documentation | 100% | (Complete CoCs / Required CoCs) × 100 |305306---307308## QMS Process Reference309310For detailed requirements and audit questions for each ISO 13485:2016 clause, see [iso13485-clause-requirements.md](references/iso13485-clause-requirements.md).311312### Management Review Required Inputs (Clause 5.6.2)313314| Input | Source | Prepared By |315|-------|--------|-------------|316| Audit results | Internal and external audits | QA Manager |317| Customer feedback | Complaints, surveys | Customer Quality |318| Process performance | Process metrics | Process Owners |319| Product conformity | Inspection data, NCs | QC Manager |320| CAPA status | CAPA system | CAPA Officer |321| Previous actions | Prior review records | QMR |322| Changes affecting QMS | Regulatory, organizational | RA Manager |323| Recommendations | All sources | All Managers |324325### Record Retention Requirements326327> **⚠️ STATUS — QMSR transition (effective 2026-02-02):** FDA's Quality Management System Regulation (QMSR) final rule (89 FR 7496) amended 21 CFR Part 820 to **incorporate ISO 13485:2016 by reference** and removed the legacy QSR subsection structure. The section numbers below (820.30/.181/.184/.198) **no longer exist in the CFR** — they are retained only as a familiar index. The current authority for record retention is **ISO 13485:2016 §4.2.5** (retain "for at least the lifetime of the medical device as defined by the organization, but not less than two years"), with records additions in retained **21 CFR 820.35**. Cite the ISO 13485 clauses — not the 820.x numbers — in current compliance documentation.328329| Record Type | Minimum Retention | Current authority under QMSR (legacy QSR shown for index) |330|-------------|-------------------|------------------|331| Device Master Record | Life of device + 2 years | ISO 13485 §4.2.3 (medical device file)/§4.2.5 (legacy QSR 820.181, historical) |332| Device History Record | Life of device + 2 years | ISO 13485 §4.2.5 + 21 CFR 820.35 (legacy QSR 820.184, historical) |333| Design History File | Life of device + 2 years | ISO 13485 §7.3.10/§4.2.5 (legacy QSR 820.30, historical) |334| Complaint Records | Life of device + 2 years | ISO 13485 §8.2.2/§4.2.5 + 21 CFR 820.35(b) (legacy QSR 820.198, historical) |335| Training Records | Employment + 3 years | Best practice |336| Audit Records | 7 years | Best practice |337| CAPA Records | 7 years | Best practice |338| Calibration Records | Equipment life + 2 years | Best practice |339340> **Decision discipline:** This skill's checklists and tools structure QMS conformity assessment — they do not certify ISO 13485 / QMSR compliance. Final compliance determinations and record-retention decisions are yours to make and must be reviewed and signed off by the named QMR; route FDA-specific regulatory-classification questions to Regulatory Affairs and confirm current 21 CFR 820 / ISO 13485:2016 text at fda.gov before relying on any citation here.341342---343344## Decision Frameworks345346### Exclusion Justification (Clause 4.2.2)347348| Clause | Permissible Exclusion | Justification Required |349|--------|----------------------|------------------------|350| 6.4.2 | Contamination control | Product not affected by contamination |351| 7.3 | Design and development | Organization does not design products |352| 7.5.2 | Product cleanliness | No cleanliness requirements |353| 7.5.3 | Installation | No installation activities |354| 7.5.4 | Servicing | No servicing activities |355| 7.5.5 | Sterile products | No sterile products |356357### Nonconformity Disposition Decision Tree358359```360Nonconforming Product Identified361 │362 ▼363 Can it be reworked?364 │365 Yes──┴──No366 │ │367 ▼ ▼368 Is rework Can it be used369 procedure as is?370 available? │371 │ Yes──┴──No372 Yes─┴─No │ │373 │ │ ▼ ▼374 ▼ ▼ Concession Scrap or375 Rework Create approval return to376 per SOP rework needed? supplier377 procedure │378 Yes─┴─No379 │ │380 ▼ ▼381 Customer Use as is382 approval with MRB383 approval384```385386### CAPA Initiation Criteria387388| Source | Automatic CAPA | Evaluate for CAPA |389|--------|----------------|-------------------|390| Customer complaint | Safety-related | All others |391| External audit | Major NC | Minor NC |392| Internal audit | Major NC | Repeat minor NC |393| Product NC | Field failure | Trend exceeds threshold |394| Process deviation | Safety impact | Repeated deviations |395396---397398## Tools and References399400### Scripts401402| Tool | Purpose | Usage |403|------|---------|-------|404| [qms_audit_checklist.py](scripts/qms_audit_checklist.py) | Generate audit checklists by clause or process | `python qms_audit_checklist.py --help` |405406**Audit Checklist Generator Features:**407- Generate clause-specific checklists (e.g., `--clause 7.3`)408- Generate process-based checklists (e.g., `--process design-control`)409- Full system audit checklist (`--audit-type system`)410- Text or JSON output formats411- Interactive mode for guided selection412413### References414415| Document | Content |416|----------|---------|417| [iso13485-clause-requirements.md](references/iso13485-clause-requirements.md) | Detailed requirements for each ISO 13485:2016 clause with audit questions |418| [qms-process-templates.md](references/qms-process-templates.md) | Ready-to-use templates for gap analysis, audit program, document control, CAPA, supplier, training |419420### Quick Reference: Mandatory Documented Procedures421422| Procedure | Clause | Key Elements |423|-----------|--------|--------------|424| Document Control | 4.2.3 | Approval, distribution, obsolete control |425| Record Control | 4.2.4 | Identification, retention, disposal |426| Internal Audit | 8.2.4 | Program, auditor qualification, reporting |427| NC Product Control | 8.3 | Identification, segregation, disposition |428| Corrective Action | 8.5.2 | Root cause, implementation, verification |429| Preventive Action | 8.5.3 | Risk identification, implementation |430431---432433## Related Skills434435| Skill | Integration Point |436|-------|-------------------|437| [quality-manager-qmr](../quality-manager-qmr/) | Management review, quality policy |438| [capa-officer](../capa-officer/) | CAPA system management |439| [qms-audit-expert](../qms-audit-expert/) | Advanced audit techniques |440| [quality-documentation-manager](../quality-documentation-manager/) | DHF, DMR, DHR management |441| [risk-management-specialist](../risk-management-specialist/) | ISO 14971 integration |