HRI Reproducibility
Reproducibility means something specific — and harder — at HRI than at a benchmark-driven venue. You
cannot "re-run" a study of an embodied robot and real people the way you re-run a model on a test
set: the participants, the room, the exact robot, and the moment are gone. So HRI reproducibility is
about making the procedure, stimulus, and analysis transparent enough that another team could
replicate the method and readers can audit your inferences. This skill builds that story; it
pairs with the shared kit in ../../resources/code/README.md.
What "reproducible" can and cannot mean here
Be honest about the limits, and design the artifact around what is reproducible:
- Reproducible (aim for this): the study protocol, the robot behavior/stimulus, the
measures, the analysis code, and the de-identified data — enough to re-analyze your
results and to run the same study elsewhere.
- Not reproducible (say so): the exact human responses. A replication is a new sample; framing
it otherwise overclaims. State this plainly rather than let a reviewer catch the overclaim.
The replication package for an HRI study
Assemble, and reference from the paper:
- Study materials — consent-form summary, instructions/scripts, questionnaires with exact items
and scoring, interview guides, and coding schemes for qualitative work.
- Robot-behavior specification — the behaviors/conditions the robot exhibited, at enough
granularity to reproduce the stimulus: for autonomous behavior, the software version and
parameters; for Wizard-of-Oz, the wizard's action space, protocol/script, and error rates
(see
hri-experiments).
- De-identified data — participant-level data with identifiers removed, plus a codebook. Scrub
free-text and metadata that could re-identify participants.
- Analysis code — scripts that reproduce every reported statistic, figure, and table from the
shared data, with fixed seeds and pinned dependencies.
- Pre-registration — a link/ID if you pre-registered the hypotheses and analysis, with any
deviations documented.
Report the things that make a study re-runnable
- Sample and procedure in reproducible detail: recruitment, inclusion criteria, N and how it was
determined, session flow, timing, compensation.
- Apparatus: the robot platform and version, sensors, environment, and anything that would change
the interaction if swapped.
- Wizard-of-Oz disclosure and constraints, so the stimulus is not an unlogged human performance.
- Analysis decisions: exclusions and why, transformations, the exact tests, and the
confirmatory/exploratory split.
De-identification and the video
HRI artifacts contain people, which raises obligations a code-only artifact does not:
- De-identify data before sharing; get consent for data sharing at study time — retrofitting it
is usually impossible.
- The video figure and any recordings need consent for the use you are making (review-time
sharing, public archival, or conference presentation are different permissions). For review, blur
faces and mute identifying audio if consent for public use was not obtained (see
hri-supplementary).
- Vulnerable populations (children, older adults, clinical) demand extra care in what is shared at
all.
Openness at HRI (calibrated to the venue)
HRI's open-science and artifact-badge culture is less formalized than SIGSOFT's — there is not a
long-standing, uniformly enforced ACM badge track for every edition (待核实 per cycle). So treat
openness as a credibility and community-norm move, not a checkbox:
- Share what ethics allows via a DOI-issuing archive (e.g., OSF, Zenodo, figshare); avoid a personal
homepage link that both rots and de-anonymizes.
- Where confidentiality or human-subjects constraints prevent full sharing, say what and why —
an honest limitation reads far better than silence or "available on request."
- If the edition does run an artifact/reproducibility evaluation, follow it and see
hri-artifact-evaluation.
Anonymization for double-blind
Everything above must be anonymized at review time: strip author/institution names from
materials and code, host the archive behind an anonymizing view, and scrub the video and data of
identity leaks. See hri-submission for the mechanical sweep.
Anti-patterns HRI reviewers flag
- Overclaiming reproducibility — implying a human study can be exactly re-run.
- Unlogged Wizard-of-Oz — no way to reproduce the stimulus.
- "Data available on request" — treated as not available.
- Identifiable data or video shared without consent for that use.
- Analysis not reproducible from the shared data — figures that no script regenerates.
Output format
[Repro scope] procedure/stimulus/analysis reproducible? human responses correctly framed as not?
[Package] materials · robot-behavior spec (incl. WoZ) · de-identified data + codebook · analysis code
[Pre-registration] link/ID · deviations documented?
[De-identification] data scrubbed · video/audio consent for the use made?
[Openness] DOI archive · honest statement of what cannot be shared and why
[Anonymization] materials/code/archive/video anonymized for review?
[Fix queue] <ordered>
1---2name: hri-reproducibility3description: Use when building the openness and replicability story for an ACM/IEEE HRI full paper — sharing study materials, robot-behavior specifications, de-identified data, and analysis code; reporting Wizard-of-Oz and pre-registration; and stating honestly what can and cannot be reproduced in an embodied human-subjects study.4---56# HRI Reproducibility78Reproducibility means something specific — and harder — at HRI than at a benchmark-driven venue. You9cannot "re-run" a study of an embodied robot and real people the way you re-run a model on a test10set: the participants, the room, the exact robot, and the moment are gone. So HRI reproducibility is11about making the **procedure, stimulus, and analysis** transparent enough that another team could12**replicate the method** and readers can audit your inferences. This skill builds that story; it13pairs with the shared kit in [`../../resources/code/README.md`](../../resources/code/README.md).1415## What "reproducible" can and cannot mean here1617Be honest about the limits, and design the artifact around what *is* reproducible:1819- **Reproducible (aim for this):** the **study protocol**, the **robot behavior/stimulus**, the20 **measures**, the **analysis code**, and the **de-identified data** — enough to re-analyze your21 results and to run the same study elsewhere.22- **Not reproducible (say so):** the exact human responses. A replication is a *new* sample; framing23 it otherwise overclaims. State this plainly rather than let a reviewer catch the overclaim.2425## The replication package for an HRI study2627Assemble, and reference from the paper:2829- **Study materials** — consent-form summary, instructions/scripts, questionnaires with exact items30 and scoring, interview guides, and coding schemes for qualitative work.31- **Robot-behavior specification** — the behaviors/conditions the robot exhibited, at enough32 granularity to reproduce the *stimulus*: for autonomous behavior, the software version and33 parameters; for **Wizard-of-Oz**, the wizard's action space, protocol/script, and error rates34 (see `hri-experiments`).35- **De-identified data** — participant-level data with identifiers removed, plus a codebook. Scrub36 free-text and metadata that could re-identify participants.37- **Analysis code** — scripts that reproduce every reported statistic, figure, and table from the38 shared data, with fixed seeds and pinned dependencies.39- **Pre-registration** — a link/ID if you pre-registered the hypotheses and analysis, with any40 deviations documented.4142## Report the things that make a study re-runnable4344- **Sample and procedure** in reproducible detail: recruitment, inclusion criteria, N and how it was45 determined, session flow, timing, compensation.46- **Apparatus**: the robot platform and version, sensors, environment, and anything that would change47 the interaction if swapped.48- **Wizard-of-Oz disclosure** and constraints, so the stimulus is not an unlogged human performance.49- **Analysis decisions**: exclusions and why, transformations, the exact tests, and the50 confirmatory/exploratory split.5152## De-identification and the video5354HRI artifacts contain **people**, which raises obligations a code-only artifact does not:5556- **De-identify data** before sharing; get consent for data sharing at study time — retrofitting it57 is usually impossible.58- The **video figure** and any recordings need consent for the *use you are making* (review-time59 sharing, public archival, or conference presentation are different permissions). For review, blur60 faces and mute identifying audio if consent for public use was not obtained (see61 `hri-supplementary`).62- Vulnerable populations (children, older adults, clinical) demand extra care in what is shared at63 all.6465## Openness at HRI (calibrated to the venue)6667HRI's open-science and artifact-badge culture is **less formalized than SIGSOFT's** — there is not a68long-standing, uniformly enforced ACM badge track for every edition (**待核实** per cycle). So treat69openness as a **credibility and community-norm** move, not a checkbox:7071- Share what ethics allows via a DOI-issuing archive (e.g., OSF, Zenodo, figshare); avoid a personal72 homepage link that both rots and de-anonymizes.73- Where confidentiality or human-subjects constraints prevent full sharing, **say what and why** —74 an honest limitation reads far better than silence or "available on request."75- If the edition *does* run an artifact/reproducibility evaluation, follow it and see76 `hri-artifact-evaluation`.7778## Anonymization for double-blind7980Everything above must be **anonymized at review time**: strip author/institution names from81materials and code, host the archive behind an anonymizing view, and scrub the video and data of82identity leaks. See `hri-submission` for the mechanical sweep.8384## Anti-patterns HRI reviewers flag8586- **Overclaiming reproducibility** — implying a human study can be exactly re-run.87- **Unlogged Wizard-of-Oz** — no way to reproduce the stimulus.88- **"Data available on request"** — treated as not available.89- **Identifiable data or video** shared without consent for that use.90- **Analysis not reproducible from the shared data** — figures that no script regenerates.9192## Output format9394```text95[Repro scope] procedure/stimulus/analysis reproducible? human responses correctly framed as not?96[Package] materials · robot-behavior spec (incl. WoZ) · de-identified data + codebook · analysis code97[Pre-registration] link/ID · deviations documented?98[De-identification] data scrubbed · video/audio consent for the use made?99[Openness] DOI archive · honest statement of what cannot be shared and why100[Anonymization] materials/code/archive/video anonymized for review?101[Fix queue] <ordered>102```