Managing Dental Infection Control
Implements OSHA Bloodborne Pathogens (BBP) standard and CDC dental infection control guidelines with sterilization monitoring, exposure management, and compliance documentation.
Why This Skill Exists
Dental procedures generate aerosols, spatter, and direct blood contact that create occupational and patient-to-patient transmission risk for HBV, HCV, HIV, and respiratory pathogens. The CDC's 2003 Guidelines for Infection Control in Dental Health-Care Settings (updated 2016 summary) and OSHA's 29 CFR 1910.1030 impose specific engineering controls, work practice controls, and documentation requirements on every dental facility. Failures are not theoretical — documented outbreaks have been traced to improperly sterilized handpieces, waterline biofilm, and reuse of single-use devices.
This skill structures the infection control program from risk assessment through monitoring, ensuring that sterilization validation, exposure incident management, and regulatory documentation meet enforceable standards.
Checkpoint A: Pre-Program Intake (Mandatory)
- What type of dental practice is in scope (general, oral surgery, periodontics, pediatric, mobile/portable)?
- How many operatories and sterilization areas exist?
- Who is the designated Infection Control Coordinator (ICC)?
- What sterilization equipment is in use (steam autoclave, chemical vapor, dry heat, single-use disposables)?
- Is there a current written Exposure Control Plan (ECP) per OSHA 29 CFR 1910.1030(c)?
- What dental unit waterline (DUWL) treatment system is installed?
- When was the last biological indicator (BI) spore test performed and what was the result?
- Have all staff completed Hepatitis B vaccination or signed declination forms?
Documents to Request
- Current Exposure Control Plan (ECP)
- Sterilization monitoring logs (biological, chemical, mechanical indicators)
- DUWL testing results (heterotrophic plate count or ATP testing)
- Staff immunization records and HBV declination forms
- OSHA 300 log and sharps injury log
- Equipment maintenance records for autoclaves and handpieces
- Material Safety Data Sheets (SDS) for disinfectants and sterilants
- Previous inspection reports (state dental board, OSHA)
Step 1: Exposure Control Plan Review
Required ECP Components (29 CFR 1910.1030)
| Element |
Requirement |
Verification |
| Exposure determination |
List all job classifications with reasonably anticipated exposure |
Review against actual staffing |
| Schedule of implementation |
Methods of compliance for each exposure scenario |
Confirm engineering controls are current |
| HBV vaccination program |
Offered within 10 days of assignment at no cost |
Check vaccination/declination records |
| Post-exposure evaluation |
Written procedure for sharps injuries and mucosal exposure |
Confirm PEP protocol is documented |
| Sharps injury log |
Maintained separately with type, brand, department, description |
Verify log is current and complete |
| Annual review |
ECP updated annually and whenever new tasks create exposure |
Check date of last revision |
| Employee access |
ECP available to all employees and to OSHA on request |
Confirm location and accessibility |
Exposure Determination Categories
- Category I: Tasks that always involve exposure (scaling, surgery, suctioning, instrument processing)
- Category II: Tasks that may involve exposure under certain conditions (radiography, lab work)
- Category III: Tasks that never involve exposure (scheduling, billing without patient contact)
Step 2: Instrument Processing and Sterilization Monitoring
Instrument Classification (Spaulding System)
| Classification |
Definition |
Processing Required |
Examples |
| Critical |
Penetrates soft tissue or bone |
Sterilization |
Forceps, scalpels, burs, scalers |
| Semi-critical |
Contacts mucous membranes |
Sterilization preferred; high-level disinfection minimum |
Mouth mirrors, impression trays (reusable), amalgam condensers |
| Non-critical |
Contacts intact skin only |
Intermediate- or low-level disinfection |
X-ray heads, blood pressure cuffs, pulse oximeter |
Sterilization Monitoring — Three Tiers
- Mechanical monitoring: Record time, temperature, and pressure for every cycle from autoclave gauges or printout
- Chemical indicators: Use internal (Type 4/5) chemical indicator inside every package; external (Type 1) indicator on outside of every package
- Biological indicators (BI): Run spore test (Geobacillus stearothermophilus for steam) at least weekly; process a BI with every implantable device load
Failed Spore Test Protocol
- Remove autoclave from service immediately
- Recall all items processed since last passing BI — do NOT use
- Retest with three consecutive BI runs
- If any BI fails again, have autoclave serviced and retested before returning to use
- Document the entire incident including recall actions in the sterilization log
Step 3: Dental Unit Waterline Management
CDC Standard
Dental unit water must meet EPA drinking water standard: ≤ 500 CFU/mL of heterotrophic bacteria.
DUWL Protocol
- Install anti-retraction valves on all handpiece connections
- Flush waterlines for 20–30 seconds between patients
- Flush all lines for 2 minutes at the start of each day
- Treat waterlines with EPA-registered product per manufacturer's protocol (chemical tablets, continuous dosing, or cartridge filters)
- Test water output at least quarterly using commercial HPC mail-in kits or in-office ATP testing
- Use sterile water or sterile saline delivered through a separate sterile irrigation system for all surgical procedures
- Document all test results; if > 500 CFU/mL, shock-treat and retest before clinical use
Step 4: Surface Disinfection and Clinical Contact Management
Surface Categories
- Clinical contact surfaces: Light handles, bracket trays, switches, chair controls, countertops in the operatory
- Housekeeping surfaces: Floors, walls, sinks (lower contamination risk)
Disinfection Protocol for Clinical Contact Surfaces
- Clean with detergent to remove visible debris
- Apply EPA-registered hospital disinfectant with tuberculocidal claim (or intermediate-level disinfectant)
- Allow full wet contact time per manufacturer label — never wipe dry prematurely
- Alternatively, use single-use barrier covers (plastic wrap, sticky backs) and replace between patients
Special Considerations
- Blood spills require intermediate-level disinfectant (tuberculocidal) at minimum
- SARS-CoV-2 and similar respiratory pathogens: follow current CDC supplemental guidance for enhanced PPE and aerosol management
- Impressions and prosthetics must be rinsed and disinfected before transport to lab
Step 5: Personal Protective Equipment (PPE) Standards
PPE Requirements by Task
| Task |
Gloves |
Mask |
Eyewear |
Gown |
| Patient examination |
Exam gloves |
Surgical mask |
Safety glasses or face shield |
Not required unless splash risk |
| Scaling, prophylaxis |
Exam gloves |
Surgical mask (ASTM Level 2+) |
Safety glasses with side shields or face shield |
Gown if aerosol-generating |
| Surgical procedures |
Sterile surgical gloves |
Surgical mask (ASTM Level 3) |
Safety glasses or face shield |
Surgical gown |
| Instrument processing |
Heavy-duty utility gloves |
Surgical mask |
Safety glasses or face shield |
Moisture-resistant gown |
| Aerosol-generating procedures |
Exam gloves (double-gloving optional) |
N95 or higher per current respiratory guidance |
Face shield preferred over glasses |
Gown required |
PPE Donning and Doffing Sequence
Donning (in order): Gown → Mask → Eyewear → Gloves
Doffing (in order): Gloves → Hand hygiene → Eyewear → Gown → Mask → Hand hygiene
Hand Hygiene Requirements
- Perform hand hygiene before donning gloves and after removing gloves
- Use alcohol-based hand rub (ABHR, 60–95% ethanol or isopropanol) for routine hand hygiene
- Wash with soap and water when hands are visibly soiled or contaminated with blood/body fluids
- Hand hygiene compliance target: ≥ 90% per direct observation audit
Step 6: Regulated Waste Management
Waste Classification and Disposal
| Waste Type |
Definition |
Container |
Disposal Method |
| Sharps waste |
Needles, scalpel blades, broken glass, burs, orthodontic wires |
Puncture-resistant, leak-proof, closable, labeled with biohazard symbol |
Licensed biomedical waste hauler |
| Regulated medical waste (soft) |
Blood-soaked gauze, extracted teeth with amalgam, surgical tissue |
Red biohazard bag in rigid container |
Incineration or autoclaving by licensed hauler |
| Pharmaceutical waste |
Expired medications, unused anesthetic carpules |
Designated pharmaceutical waste container (NOT sharps container) |
Per EPA/DEA regulations; controlled substances require DEA-authorized disposal |
| Amalgam waste |
Scrap amalgam, amalgam capsules, extracted teeth with amalgam restorations |
Sealed container with recycling solution |
Recycled through certified amalgam recycler; do NOT place in regulated waste or trash |
| Non-regulated waste |
PPE without visible blood saturation, packaging, paper products |
Standard trash receptacle |
Normal municipal waste disposal |
Amalgam Separator Compliance
- EPA Dental Rule (40 CFR Part 441, effective July 2020): All dental practices that place or remove amalgam must install and maintain an ISO 11143-compliant amalgam separator
- Separator must capture ≥ 95% of amalgam particulate
- Maintain separator per manufacturer IFU; document replacement schedule
- Recycle collected amalgam through a certified recycler; retain recycling certificates
Step 7: Exposure Incident Management
Post-Exposure Steps (OSHA-required)
- Immediate wound care: Wash puncture sites with soap and water; flush mucous membranes with water
- Report: Employee reports incident to ICC; ICC completes sharps injury log entry
- Source patient evaluation: Request consent for HBV, HCV, HIV testing of source patient
- Exposed employee evaluation: Baseline blood draw for HBV, HCV, HIV; offer HBV post-exposure prophylaxis if non-immune
- Healthcare professional evaluation: Refer to designated healthcare professional within 24 hours
- Written opinion: Obtain healthcare professional's written opinion within 15 days
- Follow-up testing: Per PEP protocol (typically 6 weeks, 3 months, 6 months)
- Documentation: File incident in OSHA 300 log if it meets recording criteria; maintain records for duration of employment + 30 years
Checkpoint B: Post-Implementation Alignment (Mandatory)
- Has the Exposure Control Plan been reviewed and updated within the past 12 months?
- Are biological indicator results documented weekly with no unresolved failures?
- Are DUWL test results all ≤ 500 CFU/mL, with corrective action documented for any exceedance?
- Do all staff have current HBV vaccination or signed declination on file?
- Has every sharps injury in the past year been logged with complete source patient and follow-up information?
Quality Audit
| # |
Criterion |
Pass / Fail |
| 1 |
Written Exposure Control Plan exists and is dated within 12 months |
|
| 2 |
All job classifications with exposure risk are identified in ECP |
|
| 3 |
HBV vaccination or declination documented for 100% of at-risk staff |
|
| 4 |
Sterilization logs show mechanical, chemical, and biological monitoring |
|
| 5 |
Biological indicator (spore test) performed at least weekly with results recorded |
|
| 6 |
Failed BI protocol followed with recall documentation when applicable |
|
| 7 |
DUWL testing performed quarterly with results ≤ 500 CFU/mL |
|
| 8 |
Surgical procedures use sterile water/saline from a separate delivery system |
|
| 9 |
Clinical contact surfaces disinfected or barrier-covered between every patient |
|
| 10 |
Sharps injury log is current, complete, and maintained separately from OSHA 300 |
|
| 11 |
Post-exposure protocol documented and accessible to all clinical staff |
|
| 12 |
PPE (gloves, masks, eyewear, gowns) available and used per task classification |
|
| 13 |
Staff infection control training documented at hire and annually |
|
| 14 |
Regulated waste segregated and disposed per state and federal requirements |
|
Guidelines
- Never flash-sterilize (immediate-use steam sterilization) as a substitute for proper instrument inventory management — use only when delay would harm the patient
- Treat all patients as potentially infectious regardless of disclosed history (Standard Precautions)
- Replace single-use items (needles, anesthetic carpules, prophylaxis cups, suction tips) after every patient — no reprocessing
- Dental handpieces MUST be heat-sterilized between patients — surface disinfection alone is insufficient per CDC guidance
- Maintain separate clean and dirty zones in the sterilization area with unidirectional instrument flow
- Document everything contemporaneously — retrospective reconstruction of sterilization logs is not defensible during an OSHA inspection
- Stay current with CDC updates, ADA guidance, and state dental board regulations — the 2003 CDC guidelines are the floor, not the ceiling
- When in doubt about a device's reprocessing instructions, consult the manufacturer's IFU (Instructions for Use) — deviations must be documented with a risk justification
1---2name: managing-dental-infection-control3description: Implements OSHA and CDC dental infection control guidelines with sterilization monitoring documentation. Use when managing dental infection control, documenting sterilization, or maintaining infection prevention compliance.4---5
6# Managing Dental Infection Control
7
8Implements OSHA Bloodborne Pathogens (BBP) standard and CDC dental infection control guidelines with sterilization monitoring, exposure management, and compliance documentation.
9
10## Why This Skill Exists
11
12Dental procedures generate aerosols, spatter, and direct blood contact that create occupational and patient-to-patient transmission risk for HBV, HCV, HIV, and respiratory pathogens. The CDC's 2003 Guidelines for Infection Control in Dental Health-Care Settings (updated 2016 summary) and OSHA's 29 CFR 1910.1030 impose specific engineering controls, work practice controls, and documentation requirements on every dental facility. Failures are not theoretical — documented outbreaks have been traced to improperly sterilized handpieces, waterline biofilm, and reuse of single-use devices.
13
14This skill structures the infection control program from risk assessment through monitoring, ensuring that sterilization validation, exposure incident management, and regulatory documentation meet enforceable standards.
15
16---
17
18## Checkpoint A: Pre-Program Intake (Mandatory)
19
201. What type of dental practice is in scope (general, oral surgery, periodontics, pediatric, mobile/portable)?
212. How many operatories and sterilization areas exist?
223. Who is the designated Infection Control Coordinator (ICC)?
234. What sterilization equipment is in use (steam autoclave, chemical vapor, dry heat, single-use disposables)?
245. Is there a current written Exposure Control Plan (ECP) per OSHA 29 CFR 1910.1030(c)?
256. What dental unit waterline (DUWL) treatment system is installed?
267. When was the last biological indicator (BI) spore test performed and what was the result?
278. Have all staff completed Hepatitis B vaccination or signed declination forms?
28
29### Documents to Request
30
31- Current Exposure Control Plan (ECP)
32- Sterilization monitoring logs (biological, chemical, mechanical indicators)
33- DUWL testing results (heterotrophic plate count or ATP testing)
34- Staff immunization records and HBV declination forms
35- OSHA 300 log and sharps injury log
36- Equipment maintenance records for autoclaves and handpieces
37- Material Safety Data Sheets (SDS) for disinfectants and sterilants
38- Previous inspection reports (state dental board, OSHA)
39
40---
41
42## Step 1: Exposure Control Plan Review
43
44### Required ECP Components (29 CFR 1910.1030)
45
46| Element | Requirement | Verification |
47|---------|-------------|-------------|
48| Exposure determination | List all job classifications with reasonably anticipated exposure | Review against actual staffing |
49| Schedule of implementation | Methods of compliance for each exposure scenario | Confirm engineering controls are current |
50| HBV vaccination program | Offered within 10 days of assignment at no cost | Check vaccination/declination records |
51| Post-exposure evaluation | Written procedure for sharps injuries and mucosal exposure | Confirm PEP protocol is documented |
52| Sharps injury log | Maintained separately with type, brand, department, description | Verify log is current and complete |
53| Annual review | ECP updated annually and whenever new tasks create exposure | Check date of last revision |
54| Employee access | ECP available to all employees and to OSHA on request | Confirm location and accessibility |
55
56### Exposure Determination Categories
57
58- **Category I**: Tasks that always involve exposure (scaling, surgery, suctioning, instrument processing)
59- **Category II**: Tasks that may involve exposure under certain conditions (radiography, lab work)
60- **Category III**: Tasks that never involve exposure (scheduling, billing without patient contact)
61
62---
63
64## Step 2: Instrument Processing and Sterilization Monitoring
65
66### Instrument Classification (Spaulding System)
67
68| Classification | Definition | Processing Required | Examples |
69|---------------|------------|-------------------|----------|
70| Critical | Penetrates soft tissue or bone | Sterilization | Forceps, scalpels, burs, scalers |
71| Semi-critical | Contacts mucous membranes | Sterilization preferred; high-level disinfection minimum | Mouth mirrors, impression trays (reusable), amalgam condensers |
72| Non-critical | Contacts intact skin only | Intermediate- or low-level disinfection | X-ray heads, blood pressure cuffs, pulse oximeter |
73
74### Sterilization Monitoring — Three Tiers
75
761. **Mechanical monitoring**: Record time, temperature, and pressure for every cycle from autoclave gauges or printout
772. **Chemical indicators**: Use internal (Type 4/5) chemical indicator inside every package; external (Type 1) indicator on outside of every package
783. **Biological indicators (BI)**: Run spore test (Geobacillus stearothermophilus for steam) at least weekly; process a BI with every implantable device load
79
80### Failed Spore Test Protocol
81
821. Remove autoclave from service immediately
832. Recall all items processed since last passing BI — do NOT use
843. Retest with three consecutive BI runs
854. If any BI fails again, have autoclave serviced and retested before returning to use
865. Document the entire incident including recall actions in the sterilization log
87
88---
89
90## Step 3: Dental Unit Waterline Management
91
92### CDC Standard
93
94Dental unit water must meet EPA drinking water standard: ≤ 500 CFU/mL of heterotrophic bacteria.
95
96### DUWL Protocol
97
981. Install anti-retraction valves on all handpiece connections
992. Flush waterlines for 20–30 seconds between patients
1003. Flush all lines for 2 minutes at the start of each day
1014. Treat waterlines with EPA-registered product per manufacturer's protocol (chemical tablets, continuous dosing, or cartridge filters)
1025. Test water output at least quarterly using commercial HPC mail-in kits or in-office ATP testing
1036. Use sterile water or sterile saline delivered through a separate sterile irrigation system for all surgical procedures
1047. Document all test results; if > 500 CFU/mL, shock-treat and retest before clinical use
105
106---
107
108## Step 4: Surface Disinfection and Clinical Contact Management
109
110### Surface Categories
111
112- **Clinical contact surfaces**: Light handles, bracket trays, switches, chair controls, countertops in the operatory
113- **Housekeeping surfaces**: Floors, walls, sinks (lower contamination risk)
114
115### Disinfection Protocol for Clinical Contact Surfaces
116
1171. Clean with detergent to remove visible debris
1182. Apply EPA-registered hospital disinfectant with tuberculocidal claim (or intermediate-level disinfectant)
1193. Allow full wet contact time per manufacturer label — never wipe dry prematurely
1204. Alternatively, use single-use barrier covers (plastic wrap, sticky backs) and replace between patients
121
122### Special Considerations
123
124- Blood spills require intermediate-level disinfectant (tuberculocidal) at minimum
125- SARS-CoV-2 and similar respiratory pathogens: follow current CDC supplemental guidance for enhanced PPE and aerosol management
126- Impressions and prosthetics must be rinsed and disinfected before transport to lab
127
128---
129
130## Step 5: Personal Protective Equipment (PPE) Standards
131
132### PPE Requirements by Task
133
134| Task | Gloves | Mask | Eyewear | Gown |
135|------|--------|------|---------|------|
136| Patient examination | Exam gloves | Surgical mask | Safety glasses or face shield | Not required unless splash risk |
137| Scaling, prophylaxis | Exam gloves | Surgical mask (ASTM Level 2+) | Safety glasses with side shields or face shield | Gown if aerosol-generating |
138| Surgical procedures | Sterile surgical gloves | Surgical mask (ASTM Level 3) | Safety glasses or face shield | Surgical gown |
139| Instrument processing | Heavy-duty utility gloves | Surgical mask | Safety glasses or face shield | Moisture-resistant gown |
140| Aerosol-generating procedures | Exam gloves (double-gloving optional) | N95 or higher per current respiratory guidance | Face shield preferred over glasses | Gown required |
141
142### PPE Donning and Doffing Sequence
143
144**Donning (in order)**: Gown → Mask → Eyewear → Gloves
145**Doffing (in order)**: Gloves → Hand hygiene → Eyewear → Gown → Mask → Hand hygiene
146
147### Hand Hygiene Requirements
148
149- Perform hand hygiene before donning gloves and after removing gloves
150- Use alcohol-based hand rub (ABHR, 60–95% ethanol or isopropanol) for routine hand hygiene
151- Wash with soap and water when hands are visibly soiled or contaminated with blood/body fluids
152- Hand hygiene compliance target: ≥ 90% per direct observation audit
153
154---
155
156## Step 6: Regulated Waste Management
157
158### Waste Classification and Disposal
159
160| Waste Type | Definition | Container | Disposal Method |
161|-----------|-----------|-----------|----------------|
162| Sharps waste | Needles, scalpel blades, broken glass, burs, orthodontic wires | Puncture-resistant, leak-proof, closable, labeled with biohazard symbol | Licensed biomedical waste hauler |
163| Regulated medical waste (soft) | Blood-soaked gauze, extracted teeth with amalgam, surgical tissue | Red biohazard bag in rigid container | Incineration or autoclaving by licensed hauler |
164| Pharmaceutical waste | Expired medications, unused anesthetic carpules | Designated pharmaceutical waste container (NOT sharps container) | Per EPA/DEA regulations; controlled substances require DEA-authorized disposal |
165| Amalgam waste | Scrap amalgam, amalgam capsules, extracted teeth with amalgam restorations | Sealed container with recycling solution | Recycled through certified amalgam recycler; do NOT place in regulated waste or trash |
166| Non-regulated waste | PPE without visible blood saturation, packaging, paper products | Standard trash receptacle | Normal municipal waste disposal |
167
168### Amalgam Separator Compliance
169
170- EPA Dental Rule (40 CFR Part 441, effective July 2020): All dental practices that place or remove amalgam must install and maintain an ISO 11143-compliant amalgam separator
171- Separator must capture ≥ 95% of amalgam particulate
172- Maintain separator per manufacturer IFU; document replacement schedule
173- Recycle collected amalgam through a certified recycler; retain recycling certificates
174
175---
176
177## Step 7: Exposure Incident Management
178
179### Post-Exposure Steps (OSHA-required)
180
1811. **Immediate wound care**: Wash puncture sites with soap and water; flush mucous membranes with water
1822. **Report**: Employee reports incident to ICC; ICC completes sharps injury log entry
1833. **Source patient evaluation**: Request consent for HBV, HCV, HIV testing of source patient
1844. **Exposed employee evaluation**: Baseline blood draw for HBV, HCV, HIV; offer HBV post-exposure prophylaxis if non-immune
1855. **Healthcare professional evaluation**: Refer to designated healthcare professional within 24 hours
1866. **Written opinion**: Obtain healthcare professional's written opinion within 15 days
1877. **Follow-up testing**: Per PEP protocol (typically 6 weeks, 3 months, 6 months)
1888. **Documentation**: File incident in OSHA 300 log if it meets recording criteria; maintain records for duration of employment + 30 years
189
190---
191
192## Checkpoint B: Post-Implementation Alignment (Mandatory)
193
1941. Has the Exposure Control Plan been reviewed and updated within the past 12 months?
1952. Are biological indicator results documented weekly with no unresolved failures?
1963. Are DUWL test results all ≤ 500 CFU/mL, with corrective action documented for any exceedance?
1974. Do all staff have current HBV vaccination or signed declination on file?
1985. Has every sharps injury in the past year been logged with complete source patient and follow-up information?
199
200---
201
202## Quality Audit
203
204| # | Criterion | Pass / Fail |
205|---|-----------|-------------|
206| 1 | Written Exposure Control Plan exists and is dated within 12 months | |
207| 2 | All job classifications with exposure risk are identified in ECP | |
208| 3 | HBV vaccination or declination documented for 100% of at-risk staff | |
209| 4 | Sterilization logs show mechanical, chemical, and biological monitoring | |
210| 5 | Biological indicator (spore test) performed at least weekly with results recorded | |
211| 6 | Failed BI protocol followed with recall documentation when applicable | |
212| 7 | DUWL testing performed quarterly with results ≤ 500 CFU/mL | |
213| 8 | Surgical procedures use sterile water/saline from a separate delivery system | |
214| 9 | Clinical contact surfaces disinfected or barrier-covered between every patient | |
215| 10 | Sharps injury log is current, complete, and maintained separately from OSHA 300 | |
216| 11 | Post-exposure protocol documented and accessible to all clinical staff | |
217| 12 | PPE (gloves, masks, eyewear, gowns) available and used per task classification | |
218| 13 | Staff infection control training documented at hire and annually | |
219| 14 | Regulated waste segregated and disposed per state and federal requirements | |
220
221---
222
223## Guidelines
224
225- Never flash-sterilize (immediate-use steam sterilization) as a substitute for proper instrument inventory management — use only when delay would harm the patient
226- Treat all patients as potentially infectious regardless of disclosed history (Standard Precautions)
227- Replace single-use items (needles, anesthetic carpules, prophylaxis cups, suction tips) after every patient — no reprocessing
228- Dental handpieces MUST be heat-sterilized between patients — surface disinfection alone is insufficient per CDC guidance
229- Maintain separate clean and dirty zones in the sterilization area with unidirectional instrument flow
230- Document everything contemporaneously — retrospective reconstruction of sterilization logs is not defensible during an OSHA inspection
231- Stay current with CDC updates, ADA guidance, and state dental board regulations — the 2003 CDC guidelines are the floor, not the ceiling
232- When in doubt about a device's reprocessing instructions, consult the manufacturer's IFU (Instructions for Use) — deviations must be documented with a risk justification