Validating New Laboratory Tests
Structures test validation with precision, accuracy, linearity, and reference range establishment.
Why This Skill Exists
Every new laboratory test, instrument, or method must be validated before patient results are reported. CLIA 42 CFR 493.1253 requires that laboratories verify or establish performance specifications for accuracy, precision, analytical measurement range (AMR), and reportable range before introducing any test. For laboratory-developed tests (LDTs) and modified FDA-cleared tests, the laboratory must perform a full analytical validation establishing these parameters from scratch. CAP accreditation checklist GEN.20371 and method-specific checklists (CHM, HEM, etc.) mandate documented validation protocols, acceptance criteria, and laboratory director approval before go-live.
The consequences of inadequate validation are severe: inaccurate results affecting patient care, CAP citations leading to corrective action requirements, CLIA sanctions up to suspension of testing, and medicolegal liability. The CLSI EP series (EP05, EP06, EP09, EP15, EP28) provides the consensus methodology for each validation study. This skill ensures that every validation study follows CLSI methodology and meets regulatory requirements.
Checkpoint A: Pre-Draft Intake (Mandatory)
- Test/method — What analyte and platform are being validated? Default: not specified; flag [VERIFY].
- Validation type — New test (full validation), new instrument for existing test (verification), or modified method? Default: verification of FDA-cleared method.
- Regulatory classification — FDA-cleared/approved, laboratory-developed test (LDT), or modified FDA-cleared? Default: FDA-cleared.
- Specimen types — What specimen types will be tested (serum, plasma, whole blood, urine, CSF, other)? Default: serum.
- Comparator method — What is the reference or predicate method for comparison? Default: current laboratory method.
- Clinical purpose — Screening, diagnosis, monitoring, or pharmacogenomics? Default: diagnosis.
- Target go-live date — When must validation be complete? Default: 60 days.
Documents to Request
- Manufacturer's package insert with claimed performance specifications
- CLSI EP guidelines relevant to each validation study (EP05, EP06, EP09, EP15, EP28)
- Comparator method performance data (current precision, bias, AMR)
- Clinical Laboratory Improvement Advisory Committee (CLIAC) guidance for the analyte
- CAP checklist requirements for the specific test discipline
- Institutional validation protocol template
- Prior validation studies for the same analyte (if replacing an existing method)
- Proficiency testing survey results for the comparator method
Step 1: Precision Study (CLSI EP05-A3)
Evaluate the repeatability and within-laboratory precision of the new method:
Protocol:
- Minimum 2 levels of QC material or patient pools (normal and abnormal range)
- Run each level in duplicate, 2 runs per day, for a minimum of 20 days (CLSI EP05-A3 standard protocol)
- This yields at minimum 80 data points per level
Analysis:
| Precision Component |
Calculation |
Acceptance Criteria |
| Repeatability (within-run) |
SD and CV from replicates within each run |
CV <= manufacturer claim |
| Within-laboratory (total) |
SD and CV from all data across 20 days |
CV <= manufacturer claim or clinical requirement |
| Between-day |
SD component from ANOVA |
Assess for systematic day-to-day variation |
| Between-run |
SD component from ANOVA |
Assess for systematic run-to-run variation |
Acceptance: Total imprecision (CV%) must be <= the manufacturer's stated precision or <= 1/4 of the total allowable error (TEa) for the analyte (per Westgard sigma-metric guidance).
Step 2: Accuracy / Method Comparison Study (CLSI EP09-A3)
Compare the new method to the reference or comparator method:
Protocol:
- Minimum 40 patient specimens spanning the clinically relevant concentration range
- Each specimen tested by both new and comparator method within 2 hours
- Include specimens at low, normal, and high concentrations
- Test each specimen once on each method (or in duplicate if precision is a concern)
Analysis:
- Deming or Passing-Bablok regression: Slope (target 0.9-1.1), intercept (target near 0), and correlation coefficient (r >= 0.975).
- Bland-Altman difference plot: Mean bias and 95% limits of agreement.
- Medical decision point bias: Calculate bias at each clinical decision point and compare to TEa.
| Metric |
Acceptable |
Marginal |
Unacceptable |
| Slope |
0.95-1.05 |
0.90-0.95 or 1.05-1.10 |
< 0.90 or > 1.10 |
| Correlation (r) |
>= 0.975 |
0.95-0.975 |
< 0.95 |
| Bias at decision point |
< 1/2 TEa |
1/2 to 1x TEa |
> TEa |
Step 3: Analytical Measurement Range (AMR) and Linearity (CLSI EP06-A)
Verify the analytical measurement range (reportable without dilution):
Protocol:
- Prepare at minimum 5 concentration levels spanning the manufacturer's claimed AMR
- Use certified reference material, calibrator dilutions, or spiked patient pools
- Each level tested in triplicate (minimum) or quadruplicate
- Include concentrations at and beyond the claimed AMR boundaries
Analysis:
- Plot measured vs. expected values
- Calculate polynomial regression; compare first-order (linear) to higher-order models
- Non-linearity: If the difference between the linear and polynomial fit exceeds the TEa at any point, the AMR is narrowed to the linear range
Reportable Range: If the clinical range extends beyond the AMR, validate dilution protocols. Document dilution factor and recovery at each validated dilution step.
Step 4: Reference Range Verification (CLSI EP28-A3c)
Verify that the manufacturer's stated reference range is applicable to the laboratory's patient population:
Protocol — Verification (FDA-cleared tests):
- Test a minimum of 20 healthy individuals representative of the patient population (per CLSI EP28)
- If no more than 2 of 20 fall outside the manufacturer's claimed range, the reference range is verified
- If more than 2 of 20 fall outside, a full reference range study is required (120+ subjects per partition)
Protocol — Establishment (LDTs or when verification fails):
- Minimum 120 reference individuals per partition (e.g., male/female, pediatric/adult)
- Calculate 2.5th and 97.5th percentiles as reference limits using nonparametric methods
- Partition by age, sex, and other demographic variables as clinically appropriate
Step 5: Additional Validation Studies
Perform additional studies as applicable:
- Carryover study: Test high-low-low sequence to detect analyte carryover between specimens. Carryover < 1% of the high-concentration value is generally acceptable.
- Interference study (CLSI EP07): Test known interferents (hemolysis, lipemia, icterus, bilirubin, common drugs). Document interference thresholds.
- Limit of detection (LoD) / Limit of quantitation (LoQ): For assays where clinical decisions depend on low-level detection (troponin, tumor markers, drugs of abuse).
- Stability study: Specimen stability at room temperature, refrigerated, and frozen conditions.
- Specimen type comparison: If multiple specimen types are claimed (serum vs. plasma), perform a comparison study between them.
Step 6: Validation Report and Go-Live Approval
Assemble the complete validation report:
- Study summary: Test name, platform, validation type, dates performed.
- Precision results: CV% for each level with acceptance determination.
- Accuracy results: Regression statistics, Bland-Altman analysis, decision-point bias.
- AMR/linearity: Verified range with any limitations documented.
- Reference range: Verified or established, with population description.
- Additional studies: Carryover, interference, LoD/LoQ, stability.
- Limitations: Any identified limitations affecting clinical use.
- Conclusion: Statement of acceptance or rejection with rationale.
- Laboratory director signature: Required for go-live approval per CLIA.
Checkpoint B: Post-Draft Alignment (Mandatory)
- Does the precision study meet the minimum 20-day/2-run/2-level protocol per CLSI EP05?
- Does the method comparison include at least 40 specimens spanning the clinically relevant range?
- Is the AMR verified at a minimum of 5 concentration levels including boundary values?
- Is the reference range verified using 20 subjects (or established using 120+ subjects for LDTs)?
- Has the laboratory director reviewed and signed the validation report?
Quality Audit
Guidelines
- Distinguish verification (FDA-cleared, confirming manufacturer claims) from validation (LDT or modified method, establishing specifications from scratch); the regulatory burden differs significantly
- Follow CLSI EP05-A3 exactly for precision studies: 20 days minimum, 2 runs per day, 2 replicates per run — shortcuts undermine statistical power and invite CAP citations
- Include specimens at clinical decision points in the method comparison (e.g., glucose at 126 mg/dL, HbA1c at 6.5%); demonstrating acceptable performance at decision points is more clinically meaningful than overall correlation
- When the manufacturer's reference range cannot be verified, perform a full establishment study with 120+ subjects per partition rather than adopting reference ranges from literature
- Document all deviations from the planned validation protocol and justify why the deviation does not invalidate results
- Do not go live until the laboratory director has reviewed all data and signed the validation report — this is a CLIA regulatory requirement
- Retain all raw validation data, worksheets, and statistical analyses for the life of the test system or as required by institutional policy (minimum 2 years per CLIA)
- Plan for ongoing performance monitoring after go-live: compare the first month of patient results to the comparator method if running in parallel
1---
2name: validating-new-laboratory-tests
3language: en
4description: Structures test validation with precision, accuracy, linearity, and reference range establishment. Use when validating new assays, documenting method comparisons, or establishing reference ranges.
5tags:
6 - validation
7 - pathology
8metadata:
9 source: https://skillmd.com/skills/casemark/validating-new-laboratory-tests
10 author: casemark
11 practice_areas:
12 - Pathology
13 - Laboratory Medicine
14 document_types:
15 - Validation Report
16 skill_modes:
17 - Validation
18---
19
20# Validating New Laboratory Tests
21
22Structures test validation with precision, accuracy, linearity, and reference range establishment.
23
24## Why This Skill Exists
25
26Every new laboratory test, instrument, or method must be validated before patient results are reported. CLIA 42 CFR 493.1253 requires that laboratories verify or establish performance specifications for accuracy, precision, analytical measurement range (AMR), and reportable range before introducing any test. For laboratory-developed tests (LDTs) and modified FDA-cleared tests, the laboratory must perform a full analytical validation establishing these parameters from scratch. CAP accreditation checklist GEN.20371 and method-specific checklists (CHM, HEM, etc.) mandate documented validation protocols, acceptance criteria, and laboratory director approval before go-live.
27
28The consequences of inadequate validation are severe: inaccurate results affecting patient care, CAP citations leading to corrective action requirements, CLIA sanctions up to suspension of testing, and medicolegal liability. The CLSI EP series (EP05, EP06, EP09, EP15, EP28) provides the consensus methodology for each validation study. This skill ensures that every validation study follows CLSI methodology and meets regulatory requirements.
29
30---
31
32## Checkpoint A: Pre-Draft Intake (Mandatory)
33
341. **Test/method** — What analyte and platform are being validated? Default: not specified; flag [VERIFY].
352. **Validation type** — New test (full validation), new instrument for existing test (verification), or modified method? Default: verification of FDA-cleared method.
363. **Regulatory classification** — FDA-cleared/approved, laboratory-developed test (LDT), or modified FDA-cleared? Default: FDA-cleared.
374. **Specimen types** — What specimen types will be tested (serum, plasma, whole blood, urine, CSF, other)? Default: serum.
385. **Comparator method** — What is the reference or predicate method for comparison? Default: current laboratory method.
396. **Clinical purpose** — Screening, diagnosis, monitoring, or pharmacogenomics? Default: diagnosis.
407. **Target go-live date** — When must validation be complete? Default: 60 days.
41
42### Documents to Request
43
44- Manufacturer's package insert with claimed performance specifications
45- CLSI EP guidelines relevant to each validation study (EP05, EP06, EP09, EP15, EP28)
46- Comparator method performance data (current precision, bias, AMR)
47- Clinical Laboratory Improvement Advisory Committee (CLIAC) guidance for the analyte
48- CAP checklist requirements for the specific test discipline
49- Institutional validation protocol template
50- Prior validation studies for the same analyte (if replacing an existing method)
51- Proficiency testing survey results for the comparator method
52
53---
54
55## Step 1: Precision Study (CLSI EP05-A3)
56
57Evaluate the repeatability and within-laboratory precision of the new method:
58
59**Protocol:**
60- Minimum 2 levels of QC material or patient pools (normal and abnormal range)
61- Run each level in duplicate, 2 runs per day, for a minimum of 20 days (CLSI EP05-A3 standard protocol)
62- This yields at minimum 80 data points per level
63
64**Analysis:**
65
66| Precision Component | Calculation | Acceptance Criteria |
67|---|---|---|
68| Repeatability (within-run) | SD and CV from replicates within each run | CV <= manufacturer claim |
69| Within-laboratory (total) | SD and CV from all data across 20 days | CV <= manufacturer claim or clinical requirement |
70| Between-day | SD component from ANOVA | Assess for systematic day-to-day variation |
71| Between-run | SD component from ANOVA | Assess for systematic run-to-run variation |
72
73**Acceptance**: Total imprecision (CV%) must be <= the manufacturer's stated precision or <= 1/4 of the total allowable error (TEa) for the analyte (per Westgard sigma-metric guidance).
74
75---
76
77## Step 2: Accuracy / Method Comparison Study (CLSI EP09-A3)
78
79Compare the new method to the reference or comparator method:
80
81**Protocol:**
82- Minimum 40 patient specimens spanning the clinically relevant concentration range
83- Each specimen tested by both new and comparator method within 2 hours
84- Include specimens at low, normal, and high concentrations
85- Test each specimen once on each method (or in duplicate if precision is a concern)
86
87**Analysis:**
88- **Deming or Passing-Bablok regression**: Slope (target 0.9-1.1), intercept (target near 0), and correlation coefficient (r >= 0.975).
89- **Bland-Altman difference plot**: Mean bias and 95% limits of agreement.
90- **Medical decision point bias**: Calculate bias at each clinical decision point and compare to TEa.
91
92| Metric | Acceptable | Marginal | Unacceptable |
93|---|---|---|---|
94| Slope | 0.95-1.05 | 0.90-0.95 or 1.05-1.10 | < 0.90 or > 1.10 |
95| Correlation (r) | >= 0.975 | 0.95-0.975 | < 0.95 |
96| Bias at decision point | < 1/2 TEa | 1/2 to 1x TEa | > TEa |
97
98---
99
100## Step 3: Analytical Measurement Range (AMR) and Linearity (CLSI EP06-A)
101
102Verify the analytical measurement range (reportable without dilution):
103
104**Protocol:**
105- Prepare at minimum 5 concentration levels spanning the manufacturer's claimed AMR
106- Use certified reference material, calibrator dilutions, or spiked patient pools
107- Each level tested in triplicate (minimum) or quadruplicate
108- Include concentrations at and beyond the claimed AMR boundaries
109
110**Analysis:**
111- Plot measured vs. expected values
112- Calculate polynomial regression; compare first-order (linear) to higher-order models
113- Non-linearity: If the difference between the linear and polynomial fit exceeds the TEa at any point, the AMR is narrowed to the linear range
114
115**Reportable Range**: If the clinical range extends beyond the AMR, validate dilution protocols. Document dilution factor and recovery at each validated dilution step.
116
117---
118
119## Step 4: Reference Range Verification (CLSI EP28-A3c)
120
121Verify that the manufacturer's stated reference range is applicable to the laboratory's patient population:
122
123**Protocol — Verification (FDA-cleared tests):**
124- Test a minimum of 20 healthy individuals representative of the patient population (per CLSI EP28)
125- If no more than 2 of 20 fall outside the manufacturer's claimed range, the reference range is verified
126- If more than 2 of 20 fall outside, a full reference range study is required (120+ subjects per partition)
127
128**Protocol — Establishment (LDTs or when verification fails):**
129- Minimum 120 reference individuals per partition (e.g., male/female, pediatric/adult)
130- Calculate 2.5th and 97.5th percentiles as reference limits using nonparametric methods
131- Partition by age, sex, and other demographic variables as clinically appropriate
132
133---
134
135## Step 5: Additional Validation Studies
136
137Perform additional studies as applicable:
138
139- **Carryover study**: Test high-low-low sequence to detect analyte carryover between specimens. Carryover < 1% of the high-concentration value is generally acceptable.
140- **Interference study (CLSI EP07)**: Test known interferents (hemolysis, lipemia, icterus, bilirubin, common drugs). Document interference thresholds.
141- **Limit of detection (LoD) / Limit of quantitation (LoQ)**: For assays where clinical decisions depend on low-level detection (troponin, tumor markers, drugs of abuse).
142- **Stability study**: Specimen stability at room temperature, refrigerated, and frozen conditions.
143- **Specimen type comparison**: If multiple specimen types are claimed (serum vs. plasma), perform a comparison study between them.
144
145---
146
147## Step 6: Validation Report and Go-Live Approval
148
149Assemble the complete validation report:
150
1511. **Study summary**: Test name, platform, validation type, dates performed.
1522. **Precision results**: CV% for each level with acceptance determination.
1533. **Accuracy results**: Regression statistics, Bland-Altman analysis, decision-point bias.
1544. **AMR/linearity**: Verified range with any limitations documented.
1555. **Reference range**: Verified or established, with population description.
1566. **Additional studies**: Carryover, interference, LoD/LoQ, stability.
1577. **Limitations**: Any identified limitations affecting clinical use.
1588. **Conclusion**: Statement of acceptance or rejection with rationale.
1599. **Laboratory director signature**: Required for go-live approval per CLIA.
160
161---
162
163## Checkpoint B: Post-Draft Alignment (Mandatory)
164
1651. Does the precision study meet the minimum 20-day/2-run/2-level protocol per CLSI EP05?
1662. Does the method comparison include at least 40 specimens spanning the clinically relevant range?
1673. Is the AMR verified at a minimum of 5 concentration levels including boundary values?
1684. Is the reference range verified using 20 subjects (or established using 120+ subjects for LDTs)?
1695. Has the laboratory director reviewed and signed the validation report?
170
171---
172
173## Quality Audit
174
175- [ ] Validation type correctly classified (verification vs. full validation vs. modification)
176- [ ] Precision study follows CLSI EP05-A3 protocol (20 days, 2 runs, 2 levels)
177- [ ] Total CV% meets acceptance criteria (manufacturer claim or clinical requirement)
178- [ ] Method comparison includes >= 40 specimens across the concentration range
179- [ ] Regression statistics and Bland-Altman analysis documented
180- [ ] Bias at medical decision points compared to TEa
181- [ ] AMR verified at >= 5 concentration levels per CLSI EP06
182- [ ] Dilution protocol validated if reportable range exceeds AMR
183- [ ] Reference range verified (20 subjects) or established (120+ subjects)
184- [ ] Interference studies performed for hemolysis, lipemia, icterus
185- [ ] LoD/LoQ established for analytically sensitive assays
186- [ ] Validation report signed by laboratory director before go-live
187- [ ] CAP checklist requirements met for the specific test discipline
188
189---
190
191## Guidelines
192
193- Distinguish verification (FDA-cleared, confirming manufacturer claims) from validation (LDT or modified method, establishing specifications from scratch); the regulatory burden differs significantly
194- Follow CLSI EP05-A3 exactly for precision studies: 20 days minimum, 2 runs per day, 2 replicates per run — shortcuts undermine statistical power and invite CAP citations
195- Include specimens at clinical decision points in the method comparison (e.g., glucose at 126 mg/dL, HbA1c at 6.5%); demonstrating acceptable performance at decision points is more clinically meaningful than overall correlation
196- When the manufacturer's reference range cannot be verified, perform a full establishment study with 120+ subjects per partition rather than adopting reference ranges from literature
197- Document all deviations from the planned validation protocol and justify why the deviation does not invalidate results
198- Do not go live until the laboratory director has reviewed all data and signed the validation report — this is a CLIA regulatory requirement
199- Retain all raw validation data, worksheets, and statistical analyses for the life of the test system or as required by institutional policy (minimum 2 years per CLIA)
200- Plan for ongoing performance monitoring after go-live: compare the first month of patient results to the comparator method if running in parallel